• 제목/요약/키워드: Water loss

검색결과 3,663건 처리시간 0.031초

새만금 유역의 토양유실량 예측을 위한 밭 토양의 작물경작인자 산정 (Estimation of Upland Cropping Management Factor for predicting Soil Loss in Saemangeum Watershed)

  • 조영경;이은정;김학관;박승우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1586-1590
    • /
    • 2006
  • In order to calculate the actual erosion according to the universal soil loss equation (USLE) and to estimate the impact of land use on soil erosion in Saemangeum, it is important to know the C-factor. Based on the USLE crop-growth stages, the cover-management C-factors were calculated for the main crop and crop rotation systems by National Institute of Agricultural Science and Technology. Combining this result with statistical data about crop cultivation area and crop rotation systems, C-factors of each administrative district in Saemangeum watershed were calculated. The range of C-factors were between 0.28 and 0.35. High C-factor value was obtained with Gimje (C = 0.35) and small C-factor values were found in Wanju (C = 0.28) and Jeongeup (C = 0.29). With this result, calculated annual soil loss was 2,804,483 ton per year. Because of the lack of sufficient statistical data about crop rotation systems, further studies are required on collecting field survey data.

  • PDF

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

연안해안에서 Al-Mg 합금재 프로펠러의 마멸-부식거동에 관한 연구 (The Study on the Wear-Corrosion Behavior of Al-Mg Alloy in the Coast)

  • 박희옥;임우조;박동기
    • Tribology and Lubricants
    • /
    • 제20권2호
    • /
    • pp.97-101
    • /
    • 2004
  • This paper reports the studies on the wear-corrosion behavior of Al-Mg alloy in various pH environments. In various pH of sea water, corrosion and wear-corrosion loss of Al-Mg alloy were investigated. Also, the polarization test of Al-Mg alloy using potentiostat/galvanostat was carried out. And the rubbed surface of Al-Mg alloy using scanning electron micrographs after wear-corrosion test was examined in various pH values of sea water. The main results are as following : The polarization resistance of Al-Mg alloy in pH 4 solution is higer than that in pH 6.7 solution, and the corrosion current density in pH 4 is controlled than in pH 6.7 solution. The wear-corrosion loss of Al-Mg alloy with lowering pH becomes sensitive. As the oxide product of Al-Mg alloy appears granular structure and exholiation phenomenon, wear-corrosion loss of Al-Mg alloy increases.

Investigation of a Hydrogen Mitigation System During Large Break Loss-Of-Coolant Accident for a Two-Loop Pressurized Water Reactor

  • Dehjourian, Mehdi;Sayareh, Reza;Rahgoshay, Mohammad;Jahanfarnia, Gholamreza;Shirani, Amir Saied
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1174-1183
    • /
    • 2016
  • Hydrogen release during severe accidents poses a serious threat to containment integrity. Mitigating procedures are necessary to prevent global or local explosions, especially in large steel shell containments. The management of hydrogen safety and prevention of over-pressurization could be implemented through a hydrogen reduction system and spray system. During the course of the hypothetical large break loss-of-coolant accident in a nuclear power plant, hydrogen is generated by a reaction between steam and the fuel-cladding inside the reactor pressure vessel and also core concrete interaction after ejection of melt into the cavity. The MELCOR 1.8.6 was used to assess core degradation and containment behavior during the large break loss-of-coolant accident without the actuation of the safety injection system except for accumulators in Beznau nuclear power plant. Also, hydrogen distribution in containment and performance of hydrogen reduction system were investigated.

역삼투법 해수담수화 전처리 여과공정의 최적조건 (Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis)

  • 김승현;윤종섭;이석헌
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구 (Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy)

  • 변재기;최영돈;박명호;신종근
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

Fast transport with wall slippage

  • Tang, Zhipeng;Zhang, Yongbin
    • Membrane and Water Treatment
    • /
    • 제12권1호
    • /
    • pp.37-41
    • /
    • 2021
  • This paper presents the multiscale calculation results of the very fast volume transport in micro/nano cylindrical tubes with the wall slippage. There simultaneously occurs the adsorbed layer flow and the intermediate continuum fluid flow which are respectively on different scales. The modeled fluid is water and the tube wall is somewhat hydrophobic. The calculation shows that the power loss on the tube no more than 1.0 Watt/m can generate the wall slippage even if the fluid-tube wall interfacial shear strength is 1 MPa; The power loss on the scale 104 Watt/m produces the volume flow rate through the tube more than one hundred times higher than the classical hydrodynamic theory calculation even if the fluid-tube wall interfacial shear strength is 1 MPa. When the wall slippage occurs, the volume flow rate through the tube is in direct proportion to the power loss on the tube but in inverse proportion to the fluid-tube wall interfacial shear strength. For low interfacial shear strengths such as no more than 1 kPa, the transport in the tube appears very fast with the magnitude more than 4 orders higher than the classical calculation if the power loss on the tube is on the scale 104 Watt/m.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

3수종의 침엽수조림지내 셀룰로오스 분해와 토양 환경요인과의 관계 (Relationships between Cellulose Decomposition and Soil Environmental Factors in Three Coniferous Plantations)

  • 김춘식
    • 한국농림기상학회지
    • /
    • 제14권1호
    • /
    • pp.39-44
    • /
    • 2012
  • 본 연구는 1963년도에 식재된 낙엽송, 소나무, 리기테다소나무 조림지를 대상으로 셀룰로오스 분해와 토양 환경인자 사이의 관계를 구명하기 위해 수행하였다. 셀룰로오스 분해에 영향을 미칠 수 있는 토양온도, 토양 수분함량, 토양 pH, 토양 이산화탄소 방출량을 2006년 7월부터 10월까지 4개월 동안 측정하였다. 셀룰로오스 분해율은 리기테다소나무($6.5mg\;g^{-1}\;day^{-1}$), 소나무($6.2mg\;g^{-1}\;day^{-1}$), 낙엽송($6.1mg\;g^{-1}\;day^{-1}$) 순이었으나 수종간 유의적인 차이는 없었다(P > 0.05). 셀룰로오스 분해율은 20cm 깊이의 토양 온도와 양의 상관(소나무: r = 0.77, P < 0.05; 리기테다소나무: r = 0.59, P < 0.05; 낙엽송: r = 0.48, P < 0.05)을 보였으나, 토양 pH와는 음의 상관(소나무: r = -0.63, P < 0.05; 리기테다소나무: r = -0.47, P < 0.05; 낙엽송: r = -0.43, P < 0.05)이 있었다. 토양이산화탄소방출량과 셀룰로오스 분해율은 소나무(r = 0.46, P < 0.05), 낙엽송(r = 0.37, P < 0.05), 토양 수분함량과 셀룰로오스 분해율은 소나무(r = 0.53, P < 0.05)와 유의적인 양의 상관(P < 0.05)이 있었다. 본 연구 결과에 따르면 셀룰로오스 분해는 각기 다른 침엽 수종으로부터 발생하는 토양 환경요인에 의해 영향을 받는 것으로 나타났다.

Characterization of Recycled Coarse Aggregate (RCA) via a Surface Coating Method

  • Ryou, J.S.;Lee, Y.S.
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.165-172
    • /
    • 2014
  • Recycled coarse aggregate (RCA) made from waste concrete is not a suitable structural material as it has high absorption of cement mortar, which adheres on the aggregate surface and on the tiny cracks thereon. Therefore, when using RCA made from waste concrete, much water must be added with the concrete, and slump loss occurs when transporting. Hence, its workability is significantly worse than that of other materials. In this study, surface of RCA was coated with water-soluble polycarboxylate (PC) dispersant so that its characteristics improved. Each possibility was evaluated: whether its slump loss can be controlled, by measuring its workability based on the elapsed time; and whether it can be used as a structural material, by measuring its strength. Moreover, the carbonation due to cement mortar adhesion was measured through a carbonation test. As a result, RCA coated with PC dispersant was found to be better than crushed coarse aggregate and RCA when the physical properties of the fresh concrete and the mechanical, durability of the hardened concrete were tested.