• 제목/요약/키워드: Water loss

검색결과 3,663건 처리시간 0.035초

Ultra Fine Soft Magnetic Powders Produced by High Pressure Water Atomization Process

  • Watanabe, Atsushi;Otsuka, Isamu;Wada, Kimio
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.794-795
    • /
    • 2006
  • Metal powder for dust core application was developed. The powder can be produced improved high-pressure water atomization process. The process has produced powder of spherical shape and lower coercivity. The dust core obta ined shows lower core loss.

  • PDF

지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지 (Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water)

  • 박병주;도시현;홍성호
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.

국가대표 투기종목 선수들의 급속 체중 감량과 신체적, 심리적 고충 (Rapid Weight Loss and Physical and Psychological Difficulties in National Combat Sports Athletes)

  • 김현철;박기준
    • 대한물리의학회지
    • /
    • 제15권3호
    • /
    • pp.61-68
    • /
    • 2020
  • PURPOSE: The purpose of this study was to investigate the current state of rapid weight loss and physical and mental complaints among elite combat athletes who were selected and trained as national representatives. METHODS: A total of 127 combat athletes who had trained at the national training center in 2019 were enrolled. The questionnaire used as the survey tool was interpreted as words that Korean athletes could easily understand based on the Portuguese version of the 'Rapid Weight Loss Questionnaire' (RWLQ). χ2 tests was performed to determine the differences in physical and mental changes according to sports and weight loss method. RESULTS: Combat athletes in Korea regularly undergo rapidly weight loss within a short period of time prior to competition. There were statistically similar results in terms of weight loss method, physical and mental changes and information about weight loss according to the sport. Weight loss methods often limit food and water intake and dehydrate. The physical complaints associated with them are symptoms such as "no energy", "dizziness", and "muscle spasms". The mental complaints include "irritability", "concentration loss" and "anxiety". These symptoms can be caused by side effects such as food intake limitation, water restriction and dehydration. Information sources for weight loss were in the order of "senior or colleagues", "supervisor or coach", and "Internet". No information was obtained from a doctor or dietitian. CONCLUSION: These results provide a baseline for predicting proper weight loss in athletes and provide useful information for developing performance enhancement as well as weight loss.

고성능감수제(高性能減水劑)를 사용한 콘크리트의 유동성(流動性) 손실(損失)을 저감(低減)시키기 위한 연구(硏究) (A Study for Reducing the Slump Loss of Concrete Using High Range Water Reducing Admixture)

  • 문한영;김기형
    • 대한토목학회논문집
    • /
    • 제12권3호
    • /
    • pp.81-90
    • /
    • 1992
  • 고성능감수제를 사용한 콘크리트의 유동성 손실을 저감시키기 위한 연구의 일환으로 시멘트의 종류, 고성능감수제의 종류, 사용방법 및 사용량이 굳지않은 콘크리트의 유동성 손실에 미치는 영향을 파악하기 위하여 시멘트풀, 모르터 및 콘크리트의 유동성 손실과 관련된 실험을 통하여 얻어진 결과에 대하여 고찰하였다. 본 연구결과 고성능감수제의 첨가시기는 시멘트 및 고성능감수제의 종류에 따라 다소 차이가 있으나 30분후 첨가방법이 유동성 손실을 줄이는데 유효하였으며, 대체로 고성능감수제 사용량이 많을수록 유동성 손실이 크게 나타났으며 보통포틀랜드시멘트 콘크리트가 유동성 손실이 가장 크고 플라이애쉬 20% 혼합시멘트 콘크리트에 나프탈린계 고성능감수제를 30분후 첨가한 경우 유동성 손실이 매우 작은 효과가 있었다.

  • PDF

수두손실률, 투수계수 및 공극비의 상호관계를 통한 제체의 다짐상태 평가 (The Estimation of Compacted State on Sea Dike Embankment with the Interrelationships Between the Hydraulic Head Loss Rate, the Hydraulic Conductivity and the Void Ratio)

  • 임성훈
    • 한국농공학회논문집
    • /
    • 제57권1호
    • /
    • pp.11-23
    • /
    • 2015
  • In this study the laboratory test for hydraulic conductivity and the seepage analysis with finite element method on measurement section of sea dike embankment were performed for the purpose of estimating the relative density of embankment from the measured pore water pressures, and both results of the test and the analysis were coupled with the method of estimating seepage blocking state with the hydraulic head loss rate in sea dike embankment. The relationship of void ratio vs hydraulic head loss rate was obtained by setting hydraulic conductivity as common ordinate on the relationships between the void ratio and the hydraulic conductivity and between the hydraulic conductivity and the hydraulic head loss rate. The void ratio on the segment between measuring points was calculated from the coupled relationship of the void ratio vs the hydraulic conductivity. The allowable upper and lower limits of hydraulic head loss rate and those of void ratio on the safety were generated from the coupled relationship between the laboratory compaction test and the sedimentation test. Current hydraulic head loss rate and void ratio were evaluated in the allowable range between upper and lower limits.

오존 정수처리 음용수조 구조물에 사용하는 에폭시 수지 방수.방식재의 표면특성 평가 (A Study on the Surface Deterioration Evaluation of Epoxy Resin Coating as Anticorrosive Material of Concrete Water Tank Using Ozone($O_3$))

  • 오상근;강효진;곽규성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 2003
  • Recently, advanced systems for water treatment are introduced for water quality improvement. One of those systems is water treatment method using ozone($O_3$). For it has strong oxidizing energy, it is necessary to have materisl stability against $O_3$. In this paper, epoxy resin specimens using as anticorrosive material of concrete structure for drink water are used to serve as a material of deterioration evaluation. It is to be studied weight loss, surface corrosion of specimens, ingredient analysis of floating particle, a solute of chemical ingredient by way of accelerated ozone testing. As the results of experiment, specimen weight is decreased. The surface of specimen is eroded heavily and showed a loss of gloss and floating particle, and in the stability for drinking water, harmful ingredient is not detected in the water.

  • PDF

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

Quasi-Distributed Water Detection Sensor Based On a V-Grooved Single-Mode Optical Fiber Covered with Water-Soluble Index-Matched Medium

  • Kim, Dae Hyun;Kim, Kwang Taek
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.1-5
    • /
    • 2015
  • The V-grooved single-mode fiber in which a surface part of the core was removed was investigated as a quasi-distributed water detection sensor. In the normal state, the V-grooved region is filled and covered with a specific RI (Refractive Index)-matched medium, and the sensor experiences minimal optical loss. As water invades the V-grooved region, the material is dissolved and removed, and a considerable optical loss occurs owing to the large RI difference between the fiber core and water. The experimental results showed the feasibility of the device as a sensor element of the quasi-distributed water detection sensor system based on general optical time domain reflectometry (OTDR).

수도사업자의 주요 운영지표와 ILI(Infrastructure Leakage Index)와의 상관관계 분석 (Correlation analysis of key operating indicators of waterworks with the Infrastructure Leakage Index (ILI))

  • 전승희;현인환;김두일
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.237-246
    • /
    • 2021
  • The ILI, developed by the IWA (International Water Association), has been used in many countries as an indicator of water leakage. In Korea, the revenue water has been used as a performance indicator for waterworks although there is an opinion to replace it with the ILI. Hence, it has been necessary to investigate whether the ILI can replace the revenue water in Korea. The four main operating indicators (i.e., water service population, profit-loss ratio, fiscal self-reliance, and aged pipe rate) of 162 Korean waterworks were compared with the ILI with the linear regression method. Local water authorities with more than 1 million water service population, with more than 60% profit-loss ratio, more than 40% and less than 60% fiscal self-reliance, and more than 20% aged pipe rate showed meaningful correlation between the four parameters and the ILI. In the remaining cases, their correlations were little or weak. This means that using the ILI may not be an efficient method to represent the performance of the water supply system in Korea because of the lack of UARL (Unavoidable Annual Real Losses) data accuracy. To use the ILI in Korea, it will be required to carry out an additional research to accumulate reliable CARL (Current Annual Real Losses) and UARL data in the future.

Comparative Water Relations of Two Vitis vinifera Cultivars, Riesling and Chardonnay

  • Park, Yong-Mok
    • The Korean Journal of Ecology
    • /
    • 제24권4호
    • /
    • pp.223-226
    • /
    • 2001
  • The leaf water relations and photosynthetic rate during acute soil drying were compared in potgrown grapevine cultivars, Vitis vinifera cv. Chardonnay and V. vinifera cv. Riesling. Leaf water potential in Riesling decreased significantly from day 2 after water had been withheld, while in Chardonnay leaf water potential for the water-stressed plants was almost identical with that in well watered plants during the first 4 days. Higher stomatal conductance and photosynthetic rate in Chardonnay than Riesling were observed until day 3 after withholding water. Photosynthetic rate in water-stressed Chardonnay was not different from that in control plants until day 3 after withholding water, while that in water-stressed Riesling was reduced markedly from day 2. In Riesling, osmotic potential at turgor loss point was not changed irrespective of watering conditions. However, in Chardonnay osmotic potential at turgor loss point decreased more in the water stressed conditions than in well watered conditions. The osmotic adjustment in Chardonnay under water stress conditions must contribute to the maintenance of higher stomatal conductance and photosynthetic rate than those in Riesling for a significant period of the drying process. Though difference in stomatal conductance between the two cultivars was shown in the process of soil drying, stomatal conductance of both cultivars responded to vapor pressure difference between leaf and ambient air, rather than soil water status and leaf water potential.

  • PDF