A Study for Reducing the Slump Loss of Concrete Using High Range Water Reducing Admixture

고성능감수제(高性能減水劑)를 사용한 콘크리트의 유동성(流動性) 손실(損失)을 저감(低減)시키기 위한 연구(硏究)

  • 문한영 (한양대학교 공과대학 토목공학과) ;
  • 김기형 (한양대학교 대학원 토목공학과)
  • Received : 1992.07.10
  • Published : 1992.09.30

Abstract

This study gives results of 1aboratory investigations to minimize the slump loss of concrete using high range water reducing admixture (HRWR). Various factors influencing on the slump loss such as cement type, HRWR type and dosage time are investigated. The acquired results indicated that 30 minutes delayed dosage of HRWR is very effective on reducing the slump loss though this tendency makes a difference to some extent according to cement and HRWR type. For the most part, the more usage of HRWR increases, the higher the slump loss occurs and concrete using ordinary portland cement has the highest slump loss and concrete using fly ash 20% replacement cement with HRWR of naphthalene type has the good effect on reducing the slump loss.

고성능감수제를 사용한 콘크리트의 유동성 손실을 저감시키기 위한 연구의 일환으로 시멘트의 종류, 고성능감수제의 종류, 사용방법 및 사용량이 굳지않은 콘크리트의 유동성 손실에 미치는 영향을 파악하기 위하여 시멘트풀, 모르터 및 콘크리트의 유동성 손실과 관련된 실험을 통하여 얻어진 결과에 대하여 고찰하였다. 본 연구결과 고성능감수제의 첨가시기는 시멘트 및 고성능감수제의 종류에 따라 다소 차이가 있으나 30분후 첨가방법이 유동성 손실을 줄이는데 유효하였으며, 대체로 고성능감수제 사용량이 많을수록 유동성 손실이 크게 나타났으며 보통포틀랜드시멘트 콘크리트가 유동성 손실이 가장 크고 플라이애쉬 20% 혼합시멘트 콘크리트에 나프탈린계 고성능감수제를 30분후 첨가한 경우 유동성 손실이 매우 작은 효과가 있었다.

Keywords

Acknowledgement

Supported by : 한국과학재단