• 제목/요약/키워드: Water loss

검색결과 3,663건 처리시간 0.032초

한국형 토양유실공식의 GIS 기반 모형에 의한 금강 유역에 대한 토양유실 우심지역 선정에 관한 연구 (A Study to Define Area of Concern for Potential Soil Loss in Geumgang Watershed by KORSLE-based GIS model)

  • 김종건;양재의;임경재;김성철;이기하;황상일;유나영;박윤식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권6호
    • /
    • pp.29-36
    • /
    • 2017
  • Universal soil loss equation (USLE) has been frequently employed to estimate potential soil loss in land since it was developed based on the statewide data measured and collected in the United States. The equation is an empirical model mainly used for U.S. soil, thus it has been recently modified to reflect Korean soil conditions and named as Korean Soil Loss Equation (KORSLE). The modified equation was implemented in ArcGIS software, and used for estimation of potential soil loss from 2003 to 2016 in the thirty-eight Water Protection Districts. Five out of the thirty-eight districts were identified as the area of potential soil erosion most severly. In those five districts, potential soil erosion were estimated to be more than 50 Mg/ha/year that requires site investigation under supervision of the Korean Ministry of Environment. Distinctive site characteristics were found in the potential soil loss estimation such that the districts of low potential soil loss had low five factors in the aggregate. However, if one of more factors are dominantly large, the potential soil loss significantly increased. This study provides a useful tool to identify the potential areas for soil erosion and the important factors that play an important role in the estimation process.

광섬유 접속부의 환경 변화에 따른 손실변화 연구 (A Study on the Optical Loss Variation of Optical Fiber Splicing Part due to Environment)

  • 유강희;김영호
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.349-357
    • /
    • 2007
  • 광섬유 케이블 포설 후 전송특성 변화에 가장 민감한 부분인 광섬유 심선 접속부의 환경변화에 따른 전송 손실의 변화를 측정하기 위하여 구부림, 온도변화, 물 침투 후의 온도변화와 진동시험 을 수행하였다. 실험결과, 구부림 시험에서는 구부림 반경이 30mm 이하에서 손실이 급격하게 증가함을 확인하였으며 $-30^{\circ}C$에서 $60^{\circ}C$범위의 온도변화에 대하여 최대 0.02dB의 손실 변화가 발생함을 확인하였다. 그러나 물이 침투한 상태에서는 훨씬 민감한 손실변화 특성을 보였으며 $-40^{\circ}C$에서 $80^{\circ}C$ 사이의 온도변화에 대하여 최대 0.2dB까지 광섬유 접속부의 손실이 증가함을 확인하였다. 또한 1mm 정도의 미세한 진동에 대해서는 광 손실의 증가가 거의 발생하지 않았다. 본 논문의 실험결과는 향후 환경변화에 따른 광섬유 접속부 손실의 변화를 제거하기 위한 광 케이블 접속함 설계에 참고자료로 사용될 수 있을 것이다.

광해복원 경사지 밭의 토양유실 평가를 위한 현장실험 - 화학적 성질과 경사도 조건에서 - (A Pilot Experiments for Evaluation of Cover Soil Loss from Inclined Upland around Remediated Abandoned Mine Site - The Condition of Chemical Characteristics and Inclination -)

  • 윤성욱;강희천;권요셉;고일하;정문호;유찬
    • 한국농공학회논문집
    • /
    • 제64권2호
    • /
    • pp.37-45
    • /
    • 2022
  • In-situ pilot experiment was carried out to establish a countermeasure on the soil loss from the hill side uplands that was rehabilitated by soil remediation method nearby abandoned mine sites for 2 years. It was considered that the affect of an inclination of cover surface, a stabilization treatment of cover layer by lime and steel refining slag (SRS) and a vegetation of soil surface as an effect factors in the experiment. It was constructed 4 lysimeters (plots, 22 m long, 4 m width) on the hilly side (37% inclination). One plot was control and two plots was treated by 1% lime and SRS. A remind one plot was modified a inclination to 27% to compare the affect of inclination on the amount of cover soil loss. It was attached a reservior tank and water level gauge in the end of lysimeters to measure the amount of the surface water flow and soil loss. It was also installed the automated sensors that could be collect the precipitation, soil moisture content, tension of cover layer in each plots. It was observed that the event of precipitation were caused the soil loss and it were related the physical and chemical properties of cover soil and inclination of surface layer of plots. During the experiment, it was exceeded the national regulation (50 t/ha/yr) in 37% inclination plots even though it was vegetated on the cover soil surface. However, in 27% inclination plot, it was shown that the amount of soil loss was maintained below the national regulation and, more ever, vegetation could reduce the the amount of soil loss. Therefore it was expected that such results could be applied to the future design of rehabilitation projects on the polluted farmland nearby abandoned mine sites.

진공포장 한우육의 냉수 침지 숙성이 지방산화, 육색소 산화 및 포장감량에 미치는 영향 (Effects of Submersion Aging in Chilled Water on Lipid Oxidation, Myoglobin Oxidation and Purge Loss of Vacuum-Packed Hanwoo Meat)

  • 정진연;허선진;이상조;양한술;문성실;이정일;김영환;주선태;박구부
    • 한국축산식품학회지
    • /
    • 제22권3호
    • /
    • pp.222-227
    • /
    • 2002
  • 진공포장한 한우육 우둔부위를 1$^{\circ}C$, 4$^{\circ}C$의 일반공기순환 냉장고와 1$^{\circ}C$, 4$^{\circ}C$의 냉수에 침지하여 3, 7, 10, 14일 동안 저장하였을 때, 처리구간의 물리적 육색 (CIE L*, a*, b*)은 크게 변화하지 않은 것으로 나타났다. 그러나 육색소 산화를 나타내는 MetMb의 함량은 처리구간에 따라 변화를 보여 대조구 (4$^{\circ}C$-공기순화)가 가장 빠른 증가를 나타내었으며, 저장 14일째 T2 (4$^{\circ}C$-냉수침지)구가 유의적으로 (p<0.05) 낮은 MetMb함량을 보였다. 한편 이런 결과는 지방산화와도 유사한 경향을 보였는데, 대조구 (4$^{\circ}C$-공기순환)의 TBARS 수치가 저장기간 동안 가장 빠른 증가를 나타낸 반면, T3(1$^{\circ}C$-냉수침지) 구의 TBARS는 크게 증가하지 않았다. 이러한 결과는 냉수침지 방법이 지방산화와 육색소 산화를 억제시킬 수 있다는 것을 의미한다. 포장감량 또는 공기순환 처리구(control, T1)가 냉수침지 처리구(T2, T3)에 비해 높게 나타났다. 총 육색소 함량은 전 저장기간 동안 처리구간에 유의적(p>0.05)인 차이가 없었다. 이상의 결과를 종합해 볼 때, 한우육을 진공포장하여 1$^{\circ}C$ 냉수에 침지시켜 숙성시키는 방법이 지방산화를 억제시키고 육색소의 안전성을 유지할 뿐만 아니라 포장감량도 줄일 수 있는 숙성법이라고 사료된다.

지형공간정보체계와 범용토양유실방정식을 이용한 유역의 토양유실 예측 (Prediction of Soil Loss in Watershed using Universal Soil Loss Equation and Geo-Spatial Information System)

  • 양인태;신계종;김동문;유영걸
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.147-154
    • /
    • 1999
  • The soil loss by rainfalls or runoffs has been one of the main environment problems in 20th century. The soil loss cause the various problems those are decreasing of the agricultural productivity, desolating of pasture land and disturbing of water flowing. Therefore, it is very important to measure properly various factors those are affecting to soil loss and to recognize a seriousness of soil loss problem. In this study, we use the USLE(Universal Soil Loss Equation) as a basic approaching way for soil loss analysis in a watershed, and the GSIS(Geo-Spatial Information System) technique is applied to evaluate for factors those are related to the USLE. The results of this study are consisted of three parts those are to build up the various topographical information that is needed for analysis of wide area soil loss by using the USLE, to evaluate the factors those are needed to the USLE, to estimate the soil loss condition of subbasin in the watershed.

  • PDF

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

피복(被服)의 보온효과에 관(關)한 연구(硏究) -비닐의 방풍효과를 중심(中心)으로- (A Study of Clothings for Cold Prevention -Protective Effects of Vinyl Sheet against Wind-)

  • 심상황;차철환;윤종준;이정희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제2권1호
    • /
    • pp.81-87
    • /
    • 1969
  • Three Combinations of cloths were evaluated for the protective effects of different kinds of clothings in cold environments. Table 1 shows the components of the three models of clothings. A prototype was made by putting a sheet of vinyl at the middle layer of raw cotton in a fabric-quilt cloths. A glove mannequin was covered by each of these cloths. The globes contained 1,000 cc of hot water about $40^{\circ}C$. Tele-thermistors were fixed in order to check the temperature of cloths space and water temperature for evaluation of calorie-loss and climate of clothings. Results are summarized as follows: 1) Without wind, there is no significant difference of air temperatures between sti-parka and quilt-wear clothing. 2) The prototype with vinyl sheet best protects against wind, the next is the ski-parka. Quilt-wear protects the least. 3) It is well-known that a working-clothing needs not have any separate liners nor outers. 4) For innermost layer of a clothing preventing cold, a cotton-fabrics is recommended and a water-proof cloths for outer layer. 5) Heat-loss was calculated from the cooling degrees of water. Calorie-loss was $910cal/m^2/hr$. when bared, but with the prototype of vinyl sheets the calorie-loss was $350cal/m^2/hr$. (38.5% of bared). Quilt-wear and ski-parka were 380(41.8%) and $440cal/m^2/hr$. (48.4%) respectively.

  • PDF

Steatite 자기의 전기적 특성에 미치는 알칼리 토금속 산화물의 영향 (Effects of Alkaline Earth Oxides on Electrical Characteristics of Steatite Porcelain)

  • 이종근;이병하;전승관
    • 한국세라믹학회지
    • /
    • 제16권1호
    • /
    • pp.31-37
    • /
    • 1979
  • The middle point of composition within the system $MgO-Al_2O_3-SiO_2$ has been studied for applicability as ceramics dielectrics. A Kyul Sung Tale of high purity, magnesia clinker of Sam-wha chemical company, C.P. aluminium oxide, calcium carbonate, red lead, barium carbonate which was made into frit were used the raw materials. A number of steatite ceramics were prepared under carefully controlled condition and the water absorption, linear shrinkage, power factor, dielectric constant and dielectric loss were measured at elevated temperature. When we used magnesia clinker as flux, the quantity of this flux was 0.05mole, sintering temperature was continued for 2 hrs. at 1, 27$0^{\circ}C$. From this conditions, we could get the data whose power factor was 0.142%, water absorption was zero, linear shrinkage was 8.76%, dielectric constant was 5.63, dielectric loss was 0.00799. When we used red lead as flux, the quantity of this flux was 0.033mole and 0.066mole, sintering temperature was continued for 2hrs. at 1, 26$0^{\circ}C$. From this conditions, we could get the data whose water absorption was zero, linear shrinkage was 8.03%, and 8.48%, power factor was 0.136% and 0.062%, dielectric loss was 0.0072 and 0.0037. When we used barium carbonate made into frit as flux, the quantity of this flux was 0.02mole, sintering temperature was continued for 2hrs. at 1, 27$0^{\circ}C$. From this conditions, we could get the data whose water absoption was zero, linear shrinkage was 8.44%, power factor was 0.138%, dielectric constant was 5.69, dielectric loss was 0.0074.

  • PDF

폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여 (On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer)

  • 홍진규;김준;최태진;윤진일
    • 한국농림기상학회지
    • /
    • 제2권3호
    • /
    • pp.80-86
    • /
    • 2000
  • 에디 공분산 방법은 생태계와 대기간의 질량과 에너지 교환을 측정하는데 널리 사용되고 있다. 이 방법은 다른 미기상학적 방법과는 달리 많은 가정을 필요로 하지 않는 직접 측정으로서, 스칼라의 농도 변화를 측정하기 위해 고속 반응의 개회로 또는 폐회로 기기를 필요로 한다. 후자를 사용할 경우, 흡입된 공기가 관을 통과하면서 스칼라의 농도 변동의 감쇠가 일어난다. 이러한 관 감쇠 효과는 측정하고자 하는 난류 플럭스를 과소 평가하게 한다. 난류 흐름의 감쇠 효과를 정량화하기 위해서 개회로 기기와 폐회로 기기로 측정된 수증기 농도를 각각 분석하였다. 통계적 분석에 의하면, 폐회로 기기에서 얻어진 스펙트럼이 0.5 Hz 이상의 영역에서 개회로 기기에서 얻어진 스펙트럼과 서로 다름을 보였다. 낮에는 관 감쇠에 의한 수증기 플럭스의 손실이 5% 이내였으나, 밤에는 풍속이 작고, 난류의 강도가 약하여 플럭스 손실이 상대적으로 크게 나타났다. 이론적으로 계산된 플럭스 손실은 관측 결과와 고주파수 영역에서 약간의 차이를 보였는데, 이것은 수증기가 관의 벽과 상호 작용하면서 플럭스 측정에 영향을 주었기 때문인 것으로 추정된다. 결론적으로, 개회로나 폐회로기기 모두 5% 오차 내에서 수증기 플럭스 관측에 사용할 수 있다. 그러나 대기가 안정할 때는 플럭스 산출시 고주파수에서의 영향을 신중히 고려해 주어야 한다.

  • PDF

진공분무 냉각에 의한 자숙 가다랑어(Katsuwonus pelamis)의 냉각 및 품질 특성에 관한 연구 (Effects of Vacuum Cooling Followed by Water Spraying on the Quality of Precooked Skipjack Katsuwonus pelamis)

  • 이태헌;구재근
    • 한국수산과학회지
    • /
    • 제47권1호
    • /
    • pp.12-17
    • /
    • 2014
  • The cooling of precooked skipjack Katsuwonus pelamis is a critical thermal process in tuna canning because it affects the quality and yield of the canned tuna, as well as productivity. The combined method of vacuum cooling followed by water spraying (VC-WS) was investigated to increase cooling rates, and prevent loss of yield of the precooked tuna during vacuum cooling. For VC-WS, the precooked skipjack was cooled to $30^{\circ}C$ by vacuum at 31 mmHg and then wetted by spraying water for 2 min. The effects of VC-WS on cooling times, cooling loss, color, texture and lipid oxidation of the precooked tuna were compared with conventional spray cooling (SC).The cooling times for precooked skipjack from $75^{\circ}C-30^{\circ}C$ were 11 min for VC-WS and 145 min for SC. The cooling losses were 1.7 % for VC-WS and 1.6 % for SC. Peroxide and thiobarbituric acid (TBA) values of VC-WS were lower than those of SC. The loin of the VC-WS-treated skipjack was brighter and harder than the SC loin, as indicated by higher lightness and hardness values. Based on these results, we believe that the VC-WS process could compensate for the cooling loss of vacuum cooling and minimize changes in quality that occur during cooling of precooked skipjack tuna.