축산용 자동급수기의 누전감지시스템에 관한 연구 (A Study on Leakage Current Detecting System for Automatic Waterer Using Livestock Barn)

  • 김두현;김성철;유상옥;김상렬;김윤복
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.34-40
    • /
    • 2011
  • This paper is purposed to develop an leakage current detecting system(LCDS) which can prevent electrical fires on breaker capacity expansion as well as ruptures of XL(Extra long) pipelines and power failure by operation of ELB(Earth leakage breaker) at auto water machine in winter. In order to develop LCDS, this paper studied field state investigation, field state experiment, development of leakage alarm system and verification experiments. Field states investigation at livestock companies(10 companies) in cheong-won location to deduce the problems of auto water machine is analyzed. The field state experiment is conducted at B livestock company in cheong won location. The field state experiment method is measured with leakage current when ELB tripped by environment factor(fine, cloudy, and rainy day). The LCDS is developed as MCU(Micro Control Unit) part applied leakage current values at B livestock company. Verification experiments for the leakage current detecting system were conducted by two methods of current supply and field test. Results show that LCDS suggested in this paper are valuable and usable in auto water machine based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in livestock.

가압형 경수로 압력용기 재료인 저합금강의 동적 붕산 부식 실증 연구 (Dynamic Boric Acid Corrosion of Low Alloy Steel for Reactor Pressure Vessel of PWR using Mockup Test)

  • 김성우;김홍표;황성식
    • Corrosion Science and Technology
    • /
    • 제12권2호
    • /
    • pp.85-92
    • /
    • 2013
  • This work is concerned with an evaluation of dynamic boric acid corrosion (BAC) of low alloy steel for reactor pressure vessel of a pressurized water reactor (PWR). Mockup test method was newly established to investigate dynamic BAC of the low alloy steel under various conditions simulating a primary water leakage incident. The average corrosion rate was measured from the weight loss of the low alloy steel specimen, and the maximum corrosion rate was obtained by the surface profilometry after the mockup test. The corrosion rates increased with the rise of the leakage rate of the primary water containing boric acid, and the presence of oxygen dissolved in the primary water also accelerated the corrosion. From the specimen surface analysis, it was found that typical flow-accelerated corrosion and jet-impingement occurred under two-phase fluid of water droplet and steam environment. The maximum corrosion rate was determined as 5.97 mm/year at the leakage rate of 20 cc/min of the primary water with a saturated content of oxygen within the range of experimental condition of this work.

침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구 (A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility)

  • 김두현;강동규
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

Leakage detection and management in water distribution systems

  • Sangroula, Uchit;Gnawali, Kapil;Koo, KangMin;Han, KukHeon;Yum, KyungTaek
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.160-160
    • /
    • 2019
  • Water is a limited source that needs to be properly managed and distributed to the ever-growing population of the world. Rapid urbanization and development have increased the overall water demand of the world drastically. However, there is loss of billions of liters of water every year due to leakages in water distribution systems. Such water loss means significant financial loss for the utilities as well. World bank estimates a loss of $14 billion annually from wasted water. To address these issues and for the development of efficient and reliable leakage management techniques, high efforts have been made by the researchers and engineers. Over the past decade, various techniques and technologies have been developed for leakage management and leak detection. These include ideas such as pressure management in water distribution networks, use of Advanced Metering Infrastructure, use of machine learning algorithms, etc. For leakage detection, techniques such as acoustic technique, and in recent yeats transient test-based techniques have become popular. Smart Water Grid uses two-way real time network monitoring by utilizing sensors and devices in the water distribution system. Hence, valuable real time data of the water distribution network can be collected. Best results and outcomes may be produced by proper utilization of the collected data in unison with advanced detection and management techniques. Long term reduction in Non Revenue Water can be achieved by detecting, localizing and repairing leakages as quickly and as efficiently as possible. However, there are still numerous challenges to be met and future research works to be conducted in this field.

  • PDF

수리시설물의 누수탐지를 위한 물리탐사의 적용성 (Applicability of Geophysical Prospecting for water leakage detection in water utilization facilities)

  • 박삼규;송성호;최종학;최보규;이병호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2002년도 정기총회 및 제4회 특별심포지움
    • /
    • pp.179-195
    • /
    • 2002
  • 본 문은 수리시설물의 누수탐지를 위한 물리탐사의 적용성에 대해서 검토했다. 저수지 및 방조제의 누수탐지를 위해서 전기비저항탐사 및 자연전위 (SP)탐사가 실시되고 있으며, 많은 사례축적으로부터 그 적용성이 입증되고 있다. 그러나, 향후 수리시설물을 보다 정확하게 누수지점을 탐지하고, 효율적인 유지관리를 위해서는 다음과 같은 사항이 요구된다. 1) 단일 탐사보다는 전기비저항탐사와 자연전위탐사를 병용 실시하여 종합적으로 해석함으로서 보다 신뢰성을 높일 수 있다. 2) 전기비저항탐사 결과로부터 누수취약구간을 정확하게 파악하기 위해서는 제체의 전기비저항을 좌우하는 토질의 물성을 잘 파악하는 것이 무엇보다도 중요하다. 3) 측정치의 보다 높은 신뢰성을 얻기 위해서는 3차원 탐사의 도입이 시급하다. 4) 수리시설물을 효율적이고 경제적으로 유지관리하기 위해서는 모니터링 계측시스템의 필요성이 요구된다.

  • PDF

적응 칼만필터를 이용한 상수관망의 누수감시 기법 (Leakage Detection of Water Distribution System using Adaptive Kalman Filter)

  • 김성원;최두용;배철호;김주환
    • 한국수자원학회논문집
    • /
    • 제46권10호
    • /
    • pp.969-976
    • /
    • 2013
  • 수돗물의 공급과정에서 발생되는 상수관망의 누수는 소중한 수자원의 손실, 공급에너지의 추가적인 소요 등 사회경제적인 손실을 초래한다. 본 연구에서는 관로 상에 설치되어 실시간으로 계측되는 유량자료를 이용하여 누수를 감시하는 모형을 적응 칼만필터 기법을 이용하여 제시하였다. 제안된 누수감시 알고리즘에서는 수돗물 사용량의 시간적 변화와 요일적 변동을 고려함으로써 예측의 신뢰도를 향상시키는 방안을 제시하였다. 또한 기존의 칼만필터 기법에 혁신과정을 추가하여 잡음의 공분산에 대한 자동보정을 통하여 예측의 정확도를 개선하였다. 개발된 모형은 사인형태의 가상 유량자료에 대한 모의실험을 통하여 적응 칼만필터 기법의 예측정확도를 기존의 칼만필터 기법과 비교하였으며, JE시의 2개소 블록유량자료에 대한 현장 적용성 평가를 실시하였다. 본 연구의 결과는 관로의 파열에 의한 누수 및 비정상적인 용수사용량에 대한 감시를 통하여 상수관망의 효율적인 운영관리에 적용될 수 있을 것으로 기대된다.

에틸렌프로필렌 고무의 전압에 의한 누설전류 특성에 관한 연구 (A Study on Properties Leakage Current due to Voltage of Ethylene Propylene Rubber)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제26권12호
    • /
    • pp.872-877
    • /
    • 2013
  • In this study, the leakage current - voltage characteristic and leakage current - time characteristic for the undegradated Ethylene Propylene Rubber and the Ethylene Propylene Rubber which is degradated by water tree for 200 hours have been measured on the temperature range of $50{\sim}80^{\circ}C$ and applied DC voltage range of 200 V~800 V for 90 minutes. The results of this study are listed below. In case the temperature is $50^{\circ}C$, it founds that the leakage current have shown a increase in proportion to the applied voltage as 2 pA in 200 V, 6 pA in 400 V, 10 pA in 600 V and 15 pA in 800 V. It founds that the leakage current increased with the rise of temperature. It founds that the leakage current was consistent as time goes by, the leakage current of the sample degradated by water tree for 200 hours has increased more than undegradated sample.

여수로 구조물 하부 암반 내 발달한 절리들을 통한 지하수 누수량 분석 (Evaluation on the leakage of ground-water through fractured rock under a spillway)

  • 김형수;정의진;이주현;이중우
    • 지구물리
    • /
    • 제9권2호
    • /
    • pp.129-134
    • /
    • 2006
  • Recently, spillways are need to control stable water level for supporting main dams because of floods by unusual change of weather such as Typhoon Rusa. This study has been focused on the amount of leakage through the rock mass distributed fractures and joints under the opened emergency spillway. It is very important to evaluate the amount of leakage as these affect stability of spillway by interaction between effective stress and pore pressure. The commercial program MAFIC has been used for analyzing groundwater flow in fractured rock mass. The results showed that the values of range, average and deviation of leakage were 2.85∼3.79×10-1, 3.32×10-1 and 1.70×10-2 m3/day/m2 respectively. Secondary, we have estimated the effect of grouting after the transmissivity(Tf) of joint 1 as main pathway of leakage known from above results was changed from 1.78×10-7 to 1.59×10-9 m2/s. The results showed that the values of range, average and deviation of leakage were 7.80×10-4∼1.53×10-3, 1.18×10-3 and 1.32×10-4 m3/day/m2 respectively. As the result, the amount of leakage after grouting has been decreased by a ratio of 1 to 277.

  • PDF