• 제목/요약/키워드: Water heater

검색결과 352건 처리시간 0.028초

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

순간 가스온수기의 CO 중독사고 예방에 관한 연구 (A Method to Prevent CO Poisoning from Instantaneous Water Heaters)

  • 안정진;여창훈;조영도
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.26-30
    • /
    • 2011
  • 개방형 순간 가스온수기는 설치와 관리가 적절히 되지 않아 일산화탄소 중독과 질식과 같은 인명사고를 발생시킬 수 있다. 연소기에 공기가 충분히 공급되지 않거나 배기구가 막히면 배기가스 중의 일산화탄소(CO)의 농도가 증가하는 특성을 보인다. 본 연구는 가정집에서 사용 중인 개방형 가스온수기를 회수하여 연소기 주변 공기 중산소농도 및 배기가스 중 CO농도의 변화를 확인하였다. 환기구 면적에 따른 산소농도 측정 실험에서 환기구의 면적이 바닥면적의 3.5%에서 산소농도가 약 17.7%로 나타났고, 배기구를 폐쇄한 상태에서 CO농도를 측정한 결과 4,000ppm이상이 측정되었다. 따라서 정기적으로 배기구를 점검하는 것이 환기구 크기보다 일산화탄소 중독사고를 예방하기 위하여 중요하다.

저온수2단흡수냉난방기의 개발 (Development of Single effect/Double lift Absorption Chiller & Heater for a District Heating Net work)

  • 구기동;김상호;류진상;이재영;서종철;장훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.668-672
    • /
    • 2009
  • This is to report the result of Development of Single effect/Double lift absorption chiller & heater which is used in the district heating net work. The heating cycle was newly developed to make the secondary hot water from evaporator and the cycle change-over function was added for the heating to the cooling mode and the cooling to the heating mode. Finally, it was assured through the site trial operation that the outlet temperature of primary hot water can be produced lower than $68^{\circ}C$ when the outlet temperature of secondary hot water is $60^{\circ}C$.

  • PDF

공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어 (Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller)

  • 정광주;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.

고압 급수가열기 추기노즐 설계변경에 따른 감육 범위 연구 (A Study on the Wall Thinning Range according to modified Extraction Nozzle Design in High Pressure Feedwater Heater)

  • 박상훈;유일곤;김경훈;황경모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.847-852
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feed-water heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare wall thinning range according to change entrance nozzle diameter and position with reference numerical analysis model's wall thinning range, various numerical analysis models applied. In case of changing diameter, four different diameter is applied. And a side of nozzle position, two different position-vertical type and parallel type-is applied. And then this paper describes operation of numerical analysis which is composed similar condition with real feed water heater. In conclusion, this study shows effective design for shall wall thinning by changing nozzle diameter and position.

  • PDF

저가 Batch형 온수급탕시스템의 실험적 연구 (Experimental Study of a Low Cost Batch Type Solar Water Heater)

  • 이길동;윤환기;강용혁;이내준;오정무
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.60-69
    • /
    • 1985
  • A low cost batch type solar heaters (capacity 200 litres) comprising horizontal tanks, which performs the dual function of absorbing heat and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing. Experimental results have indicated that the sufficient hot water can be obtained in the early morning if the glazing is aided by a reflector/insulation cover. The water heater with best thermal performance such as type B supplied water at a maximum mean temperature of $46-49^{\circ}C$ in the summer afternoon and the temperature of $36-39^{\circ}C$ can be obtained in the early morning if insulation cover is used during night time. The equation has been developed for the prediction of hourly variation of the water temperature in the tank.

  • PDF

$CO_2$ 급탕 열펌프의 성능 특성에 관한 실험적 연구 (Experimental Study on the Performance of a $CO_2$ Heat Pump Water Heater)

  • 이응찬;백창현;강훈;김용찬;조홍현;조성욱
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.367-372
    • /
    • 2009
  • The performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening, and water mass flow rate. The optimum refrigerant charge amount of the $CO_2$ system was 1800 g. At water mass flow rates of 75, 85, and 95 kg/h, the water heating temperatures were 74, 67, and $62^{\circ}C$ and COPs were 2.6, 2.8, and 3.0, respectively. Besides, the compressor frequency and water mass flow rate were adjusted to maintain the water heating temperature at $60^{\circ}C$ with the decrease of outdoor temperature. As the outdoor temperature decreased by $5^{\circ}C$, the compressor frequency increased beyond 60 Hz and the water mass flow rate decreased by 16.7%.

이산화탄소 급탕 열펌프의 난방 성능에 관한 실험적 연구 (Experimental Study on the Heating Performance of a $CO_2$ Heat Pump Water Heater)

  • 백창현;이응찬;강훈;김용찬;조홍현;조성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • In this study, experimental study on the heating performance of a $CO_2$ heat pump water heater with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening and water mass flow rate. Based on the test results, the optimum charge amount was 1800 g. At the water mass flow rates of 75, 85, 95 kg/hr, the water heating temperature was 62, 67, $74^{\circ}C$ and COP was 2.6, 2.8, 3.0, respectively. Besides, the water mass flow rate and compressor frequency were varied to maintain above the water heating temperature of $60^{\circ}C$ with the decrease of outdoor temperature. So, The compressor frequency increased beyond 65 Hz and the water mass flow rate was 45 kg/hr at the outdoor temperature of $-13^{\circ}C$, 65 kg/hr at $-8^{\circ}C$, 75 kg/hr at $-3^{\circ}C$ and 85 kg/hr at 2, $7^{\circ}C$. As the outdoor temperature decreased, the heating COP decreased by 2.5-39.8%.

  • PDF