• 제목/요약/키워드: Water filter

검색결과 1,256건 처리시간 0.027초

칼만 필터를 이용한 실시간 조위 예측 (the On-Line Prediction of Water Levels using Kalman Filters)

  • 이재형;황만하
    • 물과 미래
    • /
    • 제24권3호
    • /
    • pp.83-94
    • /
    • 1991
  • 본 논문은 차분형 천수방정식을 확장 칼만 필터로 변환하여 조석 예측을 시도하였다. 필터는 바닥마찰과 바람응력, 매개변수를 무작위 변수로 하는 추계학적 모형으로 구성되었으며 조위 및 유속과 함께 추정되도록 하였다. 물리적인 상황의 변화에 적응하도록 각 추정치들은 전파되고, 갱신된다. 본 모형에 서해안의 실측자료를 적용하여 조위의 예측을 실시한 결과, 이상 고조 기간동안에도 만족한 성과를 거두었다.

  • PDF

지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구 (Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations)

  • 안영철;이재근
    • 한국분무공학회지
    • /
    • 제9권3호
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

산화망간피복여재를 이용한 용존망간 제거 (Soluble Manganese Removal Using Manganese Oxide Coated Media (MOCM))

  • 김진근;정세채;고수현
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.813-822
    • /
    • 2006
  • Soluble manganese removal was analyzed as a function of filter media, filter depth, presence or absence of chlorination, and surface manganese oxide concentration in water treatment processes. Sand, manganese oxide coated sand (MOCS), sand+MOCS, and granular activated carbon(GAC) were used as filter media. Manganese removal, surface manganese oxide concentration, turbidity removal, and regeneration of MOCS in various filter media were investigated. Results indicated that soluble manganese removal in MOCS was rapid and efficient, and most of the removal happened at the top of the filter. When filter influent (residual chlorine 1.0mg/L) with an average manganese concentration of 0.204mg/L was fed through a filter column, the sand+MOCS and MOCS columns can remove 98.9% and 99.2% of manganese respectively on an annual basis. On the other hand, manganese removal in sand and the GAC column was minimal during the initial stage of filtration, but after 8 months of filter run they removed 99% and 35% of manganese, respectively. Sand turned into MOCS after a certain period of filtration, while GAC did not. In MOCS, the manganese adsorption rate on the filter media was inversely proportional to the filter depth, while the density of media was proportional to the filter depth.

낙동강 원수에 대한 대장균군 막여과시험법에 있어서 여러 인자가 결과에 미치는 영향 (The Influence of Various Factors upon the Membrane Filter Technique on Raw Water of the Nak-Dong River)

  • 현재열;윤종호;신상희;김종우
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.205-211
    • /
    • 2009
  • In this study, the membrane filter method was compared to the MPN method for the analysis of total coliforms from raw water using raw test waters and controls including 6 standard strains of coliforms, and the various factors were analyzed on the detection of general and fecal origin coliforms. The range of error rate for the detection of 5 standard strains using the membrane filter and the MPN methods was 0 to 6% and 45 to 133%, respectively. The error rate of the membrane filter method was lower than that of the MPN method. The membrane filter method (m-Endo) showed 10% (11 out of 111) of difference for the detection sensitivity of coliforms isolated from raw water compared to the MPN method (BGLB). The membrane filter method was less affected by the factors including temperature, turbidity, charcoals of powder form, contamination, and reverse pressure. In conclusion, the membrane filter method is a better method for the analysis of total coliforms from raw water than the MPN method, considering the accuracy of detection and the tolerance to various experimental factors.

Fabrication and Characterization of Onggi Filter for Appropriate Water Treatment Technology

  • Park, Joon-Hong;Kim, Jin-Ho;Cho, Woo-Seok;Han, Kyu-Sung;Hwang, Kwang-Taek
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.114-120
    • /
    • 2017
  • In underdeveloped countries, many people suffer from water shortage due to the absence of water supply service. Although water purifiers have provided support in such situations, it is not easy to maintain water filters without a continuous supply of consumable filters. To obtain a sustainable drinking water source, appropriate technology of water treatment is necessary. Herein, a low cost water purification system was developed using natural raw materials. A non-electric water treatment system was developed using filtration through an Onggi filter, which is a type of Korean traditional earthenware with a microporous surface. The porosity and flux of the prepared Onggi filter were 29.06% and 31.63 LMH, respectively. After purification of water with total dissolved solids of 10.4 mg/L and turbidity of 100 NTU, the total dissolved solids and turbidity of the water treated using the Onggi filter decreased by 12% and 99.8%, respectively.

정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가 (Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

분광측색계에 의한 착색 수돗물 시험방법 연구 (A study on the testing method of discolored tap water by spectrophotometer)

  • 김동헌;이종금;오지윤;김기태;전항배
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.187-202
    • /
    • 2023
  • This study focuses on the application of a new measurement method that quantifies the residual color of filtered water using a spectrocolorimeter after filtering the discolored substances. It was confirmed through the color and turbidity cross-test that the discolored substances cannot be measured effectively with the current legal color and turbidity test method. Therefore, the National Institute of Environmental Research's filter testing method, which involves filtering the sample through 0.45 ㎛ filter and visually inspecting the color, was improved. A membrane filter colorimetry (MFC) method was established by measuring the color difference (ΔE*ab(65)) of the filtered filter using a spectrophotometer and expressing it as filter color unit (FCU). Using the MFC method, the FCU for reference materials such as iron and manganese, as well as field samples, was measured. The results showed a high correlation with turbidity, and the color difference patterns varied depending on the type of reference materials and field samples. This indicates that the MFC method is an effective new measurement method of discolored tap water.

필터간격을 고려한 농업용저수지 제체의 침투특성 (Seepage Characteristics of Agricultural Reservoir Embankment Considering Filter Interval)

  • 이영학;이달원
    • 한국농공학회논문집
    • /
    • 제60권1호
    • /
    • pp.1-10
    • /
    • 2018
  • This study analyzed pore water pressure, seepage and leakage quantity, height of seepage and critical hydraulic gradient in order to suggest the seepage characteristics of agricultural reservoir embankment considering filter interval. The seepage characteristics of a deteriorated reservoir embankments were conducted according to the horizontal filter intervals range using three- dimensional finite element analysis. The wider the horizontal filter interval, the higher the pore water pressure increased, and the pore water pressure ratio in the center of the core has a greater effect than the base part. The seepage and leakage quantity appeared largely in the two-dimensional analysis conditions (case 1), where the filter was constructed totally in the longitudinal direction of the embankment, the wider the horizontal filter interval was gradually reduced. The reasonable filter intervals to yield efficient seepage characteristics were within 30 m for the pore water pressure of the core and the height of the seepage line. The stability of the filter installation was able to evaluate the stability of the piping by the critical hydraulic gradient method. The deteriorated reservoir with no filters or decreased functionality can significantly reduce the possibility of piping by simply installing a filter on the downstream slope. In the future, the deteriorated reservoir embankment should be checked for the reservoir remodeling because the core and filter functions have been lost or decreased significantly. In the case of a new installation, the seepage characteristic behavior due to the core and filter changes should be applied to the field after obtaining a reasonable horizontal filter interval that satisfies the safety factor by a three-dimensional analysis.

자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출 (Identification of operating parameters in auto-discharging filter system for treatment of urban storm water)

  • 김선희;권은미;박성순;조성주;임채환;강선홍
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

알칼리 환원수 필터의 산화환원전위 안정화 평가 (Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water)

  • 남상엽;권윤중
    • 전자공학회논문지
    • /
    • 제53권8호
    • /
    • pp.129-135
    • /
    • 2016
  • 본 연구는 알칼리 환원수기에 3가지 필터(활성카본, 중공사막, 카본블럭)를 이용해서 원수를 통과시켜 통수 양에 따른 산화환원전위(Oxidation Reduction Potential) ORP값이 안정화되는 것을 평가한 것이다. 알칼리 환원수기는 환원의 기능을 가지고 있는 물을 만드는 시스템으로 인체에 유익한 미네랄과 ORP값이 일반 물에 비해 매우 낮은 값을 가지고 있는 기능수이다. 필터를 통과한 물을 전기 분해하면 물속에 있는 음이온과 양이온은 격막을 통해서 -전극 쪽에는 칼슘($Ca^+$), 칼륨($K^+$), 마그네슘($Mg^+$), 나트륨($Na^+$)을 포함한 물로 인체에 유익한 미네랄이 포함된 알칼리 환원수를 얻고 +극에는 염소(Cl),인(P),유황(S)등 - 이온을 띄고 있는 유기물이 만들어 진다. 실험에서 알칼리 환원수(Alkaline Reduced Water)에서 전기분해의 전압의 크기를 조절하여 1단(pH8), 2단(pH8.5), 3단(pH9), 4단(pH9.5)으로 알칼리 환원수에 사용되고 -1단(pH6.0), -2단(pH5.0)의 산성산화수로 사용하고 있다. 이러한 시스템으로 3가지 필터에 통수하면서 ORP값이 어떻게 변화하고 어느 정도에서 안정화되는지를 평가하였고 대략 100L는 통수되어야 ORP값이 안정화하는 것을 측정하고 평가하였다.