• 제목/요약/키워드: Water exchange

검색결과 1,492건 처리시간 0.028초

환수율 및 접종밀도에 따른 초소형 rotifer, Synchaeta kitina의 대량배양 (Mass Culture of Ultra-small Rotifer, Synchaeta kitina at the Exchange Rate of Culture Water and Initial Inoculation Density)

  • 오정수;박진철;박흠기
    • 한국수산과학회지
    • /
    • 제42권4호
    • /
    • pp.354-359
    • /
    • 2009
  • The productivity of ultra-small rotifer, Synchaeta kitina was investigated at the exchange rate of culture water (10, 20, 30, 40 and 50%) and initial inoculation densities (250, 600 and 900 inds. per mL) in semi-continuous culture. Also, the possibility of mass culture was investigated in a 100 L culture tank. Tetraselmis suecica was used as the feed for S. kitina in all experiments. The production of S. kitina increased with an increase in exchange rate of culture water. The highest production ($82.0{\times}10^5$ inds.) was achieved at 40% exchange rate of culture water. The production of S. kitina increased with an increase of initial inoculation density during the first week and the highest total production ($17.4{\times}10^6$ inds.) was achieved at 900 inds. per mL of initial inoculation density. However, on the second week, all treatments were not significantly different in total production (P>0.05). During the two weeks, total production of S. kitina at 900 inds. per mL of initial inoculation density was higher than at 600 inds. of initial inoculation density, but there was no significant difference (P>0.05). In the 100 L culture tank, density of S. kitina was kept from 516 to 890 inds. per mL and S. kitina was daily harvested $15.5{\times}10^6$ to $26.7{\times}10^6$ during the experimental period. The production cost for 100 million rotifers in semi-continuous culture was 63,656 won. The results from this study indicate that the optimal exchange rate of culture water and initial inoculation density for the semi-continuous culture of ultra-small rotifer, S. kitina are 40% and 600 inds. per mL, respectively.

수전해 시스템에 적용하기 위한 상용 음이온교환막의 특성평가 (Evaluation of Commercial Anion Exchange Membrane for the application to Water Electrolysis)

  • 박준호;임광섭;남상용
    • 멤브레인
    • /
    • 제32권6호
    • /
    • pp.496-513
    • /
    • 2022
  • 본 연구에서는 음이온 교환막 수전해 시스템에 적용가능성을 확인하고자 상용 음이온 교환막인 FAA-3-50, Neosepta-ASE, Sustainion grade T, Fujifilm type 10의 관련 물성을 평가하였다. 음이온교환막을 이용하는 특성상 음이온교환기의 확인을 위하여 SEM/EDX를 이용하여 상용막의 모폴로지와 표면의 원소를 분석하여 상용막이 포함하고 있는 작용기의 분포를 확인하였다. 또한, UTM과 TGA를 이용하여 기계적 강도 및 열분해온도를 측정하여 수전해의 구동조건을 만족하는지 확인하였다. 음이온 교환막으로서의 성능을 파악하기 위하여 중요한 특성인 이온교환용량과 이온전도도를 측정하였으며, 알칼리 환경에서 구동되기 때문에 각각의 상용막의 내알칼리성을 확인하기 위한 내구성 테스트를 진행하여 비교하였다. 최종적으로 막-전극 접합체를 제조하여 수전해 single cell test를 진행하여 60℃, 70℃, 80℃의 온도 조건에서 cell 성능을 확인하였고 장기 cell test로 다른 온도에서 20 cycle 측정하여 수전해 성능을 비교하여 상용막의 음이온 교환막 수전해에 적용가능성을 비교하여 확인하였다.

탱커선 전용의 최적화된 밸러스트수 교체 관리 (Optimized Ballast Water Exchange Management for Tanker)

  • 홍충유;장형준;권성진;최영달;김동언;박제웅
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2003
  • Many port states such as New Zealand, the USA, Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organisms and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason, they perceived that the ballast exchange in deep sea is the most effective method, together with submitting the ballast management plan which contains the effective exchange method, ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that, it provide more convenient and stable process for preparing ballast water management plan.

  • PDF

지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구 (Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System)

  • 송재용;이근춘;박남서
    • 대한건축학회논문집:구조계
    • /
    • 제34권5호
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

바이폴라막의 물 분해 촉매 및 에너지 기술 응용의 연구 동향 (Research Trends in Bipolar Membrane for Water Dissociation Catalysts and Energy Technology Applications)

  • 김도형;남상용
    • 멤브레인
    • /
    • 제34권1호
    • /
    • pp.10-19
    • /
    • 2024
  • 바이폴라막은 양이온교환층과 음이온교환층 및 양극접합층으로 이루어진 이온교환막으로 물 분해 특성을 기반으로 하여 프로톤과 수산화 이온을 생성시키는 막이다. 이러한 특성을 이용하여 화학 산업, 식품 가공, 환경 보호, 에너지 변환 및 저장과 같은 다양한 응용 분야에서 연구가 되고 있다. 본 논문에서는 바이폴라막 기술에 대한 종합적인 이해를 제공하기 위해 바이폴라막의 개념 및 물 분해 메커니즘과 물 분해 촉매에 대한 조사하였다. 마지막으로 최근 에너지 기술에 적용되고 있는 바이폴라막 프로세스를 조사하였다.

BULK선용 자동 Ballast Water Management Plan 개발 (The development of auto Ballast Water Management Plan For Bulk Carrier.)

  • 홍충유;권영섭;권성진;황진욱;박제웅
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.266-271
    • /
    • 2003
  • Many port states such as New Zealand. the USA. Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason. they perceived that the ballast exchange in deep sea is the most effective method. together with submitting the ballast management plan which contains the effective exchange method. ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that. it provide more convenient and stable process to prepare ballast water management plan for Bulk Carrier.

  • PDF

마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구 (A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay)

  • 김권수;유하상;김강민
    • 한국항해항만학회지
    • /
    • 제37권6호
    • /
    • pp.637-645
    • /
    • 2013
  • 마산만은 반폐쇄성 해역으로, 느린 유속과 육상오염물질의 하천부하 등으로 인해 심각한 수질문제를 가지고 있으며, 동시에 폭풍해일에 취약한 입지적 특성을 나타내고 있다. 이 중 폭풍해일 저감대책으로 제시된 재해방지시설을 운용함과 동시에 이를 마산만 내측 수질개선에 활용하는 방안을 모색하였다. 즉, 재해방지시설을 가동하여 마산만 내측과 외측의 수위조건이 다를 때 발생하는 수두차를 이용하여 만 내 외의 해수를 교환하였다. 재해방지시설의 위치를 기존 만 입구부, 마창대교 인근, 그리고 돝섬 인근으로 가정하였으며, 선박운항 횟수와 연간조위를 분석하여 통항빈도가 가장 낮은 새벽시간(01~05) 및 수두차가 가장 큰 대조기에 운용된다고 가정하였다. 또한, 재해방지시설과 함께 약 10km 길이의 유출 입 관로를 통한 내 외해수의 해수교환 촉진을 위한 추가 실험안을 구성하였다. 수치모의 결과, 현재상태의 경우 마산만 전체 해수교환율은 38.62%을 나타냈으며, 모든 실험안에서 마산만 내 모든 구역에서 꾸준한 증가 추세를 보이고 있다. 이에 반해, 마산만 입구부와 비교한 마산만 내측의 해수교환율은 매우 낮게 나타나 반폐쇄성 내만해역의 특성을 잘 재현하는 것으로 판단된다. 재해방지시설과 관로를 이용한 실험안을 분석한 결과, 현재상태와 비교하여 재해방지시설을 운용한 경우 해수교환율이 높고, 그 운용빈도가 많아질수록 더 많은 순환이 이루어지는 것으로 나타났다. 또한, 재해방지시설에 의해 발생된 수두차를 이용하여 관로를 통해 해수를 유입 혹은 유출한 경우 마산만 가장 내측의 수질이 개선되는 것으로 나타났다. 재해방지시설의 위치는 마창대교 남측과 비교하여 마산만 입구와 돝섬에 위치한 경우 해수교환 효과가 더 좋게 나타났다. 한편 마산만 전체영역에 대한 해수교환율은 만 입구에 재해방지시설이 위치한 경우가 돝섬에 위치한 경우보다 높지만, 마산만 내측을 포함한 해수교환율은 반대로 돝섬에 위치한 경우가 더 높게 나타났다.

이온교환을 이용한 음용수의 $NH_3-N$ 처리 (Treatment of $NH_3-N$ in Drinking Water Using Ion Exchange)

  • 채용곤
    • 환경위생공학
    • /
    • 제23권1호
    • /
    • pp.67-72
    • /
    • 2008
  • Ion exchange performance to remove Ammonium in water was studied using commercially available strong acidic cationic exchange resin of $Na^+$ type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium concentrations for batch reactor as a function of time until resins were exhausted or reached ionic equilibrium between resin and solution. The results shoed that cationic exchange resin used in this study was more effective than activated carbon or zeolite for ammonium removal. Ammonium removal with the ion exchange resin temperature to be high qualitative recording minuteness but increases about seasonal change of temperature was judged with the public law where the adaptability is excellent. When the pH comes to be high at 11 degree, the ammonium was not effectively removed.

자성체 이온교환수지(MIEX®)를 이용한 수중의 과불화화합물(PFCs) 제거 특성 (Characteristics of Removal of Perfluorinated Compounds (PFCs) Using Magnetic Ion Exchange Resin (MIEX®) in Water)

  • 손희종;염훈식;김경아;유상원;권기원
    • 한국환경과학회지
    • /
    • 제22권8호
    • /
    • pp.1009-1017
    • /
    • 2013
  • Perfluorooctanoic acid (PFOA) and perfluorooctyl sulfonate (PFOS) is a new persistent organic pollutants of substantial environmental concern. This study investigated the potential of magnetic ion exchange resin (MIEX$^{(R)}$) as the adsorbent for the removal of PFOA and PFOS from Nakdong River water. In our batch experiments, we studied the effect of some parameters (pH, temperature, sulfate concentration) on the removal of PFOA and PFOS. The results of sorption kinetics on MIEX$^{(R)}$ show that it takes 90 min to reach equilibrium but the economical contact time and dosage were 30 min and 10 mL/L. An increase in pH (pH 6~10) leads to a decrease in PFOA (2.0%) and PFOS (3.6%) sorption on MIEX$^{(R)}$. The sorption of both PFOA and PFOS decreases with an increase in ionic strength for sulfate ion (${SO_4}^{2-}$), due to the competition phenomenon. An increase in water temperature ($8^{\circ}C{\sim}28^{\circ}C$) in water leads to a increase in PFOA (2.8%) and PFOS (4.3%) sorption on MIEX$^{(R)}$. Based on the sorption behaviors and characteristics of the adsorbents and adsorbates, ion exchange and hydrophobic interaction were deduced to be involved in the sorption, and hemi-micelles possibly formed in the intraparticle pores.

Water Glass로부터 합성한 δ-Na2Si2O5의 Ca2+, Mg2+ 이온교환성 (The Calcium and Magnesium Ion-Exchange Properties of Snythetic δ-Na2Si2O5 from Water Glass)

  • 정순용;서정권;박중환;도명기;고재천;이정민
    • 공업화학
    • /
    • 제5권3호
    • /
    • pp.406-412
    • /
    • 1994
  • Water glass로부터 ${\delta}-Na_2Si_2O_5$를 합성하여, 이의 칼슘과 마그네슘의 이온교환성, 이온교환에 대한 열역학적 특성치를 조사하였다. Water glass로부터 합성한 ${\delta}-Na_2Si_2O_5$의 최적 합성온도가 $725^{\circ}C$ 근처임을 알았다. 이온교환반응에 있어서 마그네슘 이온교환능이 칼슘 이온교환능보다 우수하였고, 마그네슘의 이온교환능은 온도에 민감하지 않은 반면에, 칼슘의 이온교환능은 온도에 민감하여 온도증가에 따라 이온교환능의 증가폭이 큼을 알 수 있었다. 초기 수용액 pH 변화에 따른 칼슘과 마그네슘의 이온교환능은 초기 수용액 pH가 2~6 사이에서 약간 감소하였으나, 6 이상에서는 ${\delta}-Na_2Si_2O_5$의 알카리 완충효과 때문에 각각 일정하게 나타났다. 이온교환 Gibbs 자유에너지는 이온교환 선택성의 역순으로 칼습 이온 교환반응이 마그네슘 이온교환반응보다 높게 나타났으며, 엔탈피와 엔트로피값도 칼슘 이온교환반응이 마그네슘 이온교환 반응보다 높게 나타났다.

  • PDF