• Title/Summary/Keyword: Water distribution

Search Result 6,876, Processing Time 0.036 seconds

Distribution of average intervent times between adjacent rainfall events for overflow risk-based design of storm-water infiltration basin (월류위험도 기반 침투형저류지 설계를 위한 평균무강우지속시간도 작성)

  • Kim, Dae Geun;Park, Sun Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.195-203
    • /
    • 2008
  • This study collected the latest 30-year (1976~2005) continuous rainfall data hourly recorded at 61 meterological observatories in Korea. The continuous rainfall data was divided into individual rainfall events. In addition, distribution charts of average intervent times between adjacent rainfall events were created to facilitate the application to the overflow risk-based design of storm-water infiltration basin. This study shows that the one-parameter exponential distribution is suitable for the frequency distribution of the average intervent times for the domestic rainfall data. Distribution charts of the average intervent times were created for 4 hour and 6 hour of storm separation time, respectively. The inland Gyeongsangbuk-do and Western coastal area had relatively longer average intervent times, whereas Southern coastal area and Jeju-do had relatively shorter average intervent times.

The assessment of self cleaning velocity and optimal flushing velocity in water distribution system (상수관망의 자가세척 유속과 적정 플러싱 유속 평가)

  • Bae, Cheol-Ho;Choi, Doo Yong;Kim, Ju-Hwan;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.

An Algorithm for Searching On-Off Valves to Isolate a Subsystem in a Water Distribution System (상수관망의 부분적 격리를 위한 제수밸브 탐색 알고리듬)

  • Jun, Hwan Don;Kim, Joong Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.35-43
    • /
    • 2006
  • Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate a subsystem due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves. Minimizing the pipe failure impact, an efficient algorithm is required to identify adjacent valves quickly. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network when a pipe failure is presented. The algorithm is operated on a matrix called the valve location matrix containing the information of valve locations. An application to an existing water distribution system demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

Analysis of Water-Quality Constituents Variations before and after Weir Construction in South Han River using Probability Distribution (확률분포를 이용한 남한강 보 건설 전·후 수질변화 분석)

  • Kim, Kyung Sub
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • The Four Major Rivers Restoration Project started in 2009 and completed in early 2013 is a large-scale inter-ministry SOC project investing ₩22.2 $10^{12}$ and one of the Project's objectives was to enhance the water-quality grade through recovering the river eco-system and environment. The average concentration and probability distribution of water-quality constituents at given and selected sampling sites are very significant elements for analyzing and controlling the water-quality of rivers or reservoirs effectively. Average concentration can be estimated by point estimator, distribution function of water-quality constituents or Bootstrap method, in which the distribution function estimated with more data in case of insufficient dataset, is applied. Ipo and Gangcheon water-quality monitoring stations in South Han River were selected to compare and analyze the variation of concentration before and after Ipo and Gangcheon Weirs construction, using the whole 4-year's data, from 2005 to 2008 and from 2014 to 2017. Water-quality constituents such as BOD and COD relating to oxygen demanding wastes and TP and Chlorophyll-a relating to the process of nutrient enrichment called eutrophication were also selected. The guidelines for water-quality control and management after weir construction including evaluation of water-quality constituents' variations can be presented by this paper.

Development of a quantification method for modelling the energy budget of water distribution system (상수관망 에너지 모의를 위한 정량화 분석기법 개발)

  • Choi, Doo Yong;Kim, Sanghyun;Kim, Kyoung-Pilc
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1223-1234
    • /
    • 2022
  • Efforts for reducing greenhouse gas emission coping with climate change have also been performed in the field of water and wastewater works. In particular, the technical development for reducing energy has been applied in operating water distribution system. The reduction of energy in water distribution system can be achieved by reducing structural loss induced by topographic variation and operational loss induced by leakage and friction. However, both analytical and numerical approaches for analyzing energy budget of water distribution system has been challengeable because energy components are affected by the complex interaction of affecting factors. This research drew mathematical equations for 5 types of state (hypothetical, ideal, leak-included ideal, leak-excluded real, and real), which depend on the assumptions of topographic variation, leakage, and friction. Furthermore, the derived equations are schematically illustrated and applied into simple water network. The suggested method makes water utilities quantify, classify, and evaluate the energy of water distribution system.

Analysis on the Relations of Droplet Size Distribution and Optical Depth in Water Curtain (워터커튼에서 액적의 크기 분포와 광학 두께의 상관관계 분석)

  • You, Woo Jun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.62-67
    • /
    • 2016
  • In this study, the optical depth is analyzed with the effects of droplet size distribution of the water curtain nozzle to attenuate the radiative heat transfer. The HELOS/VARIO equipment is used for the measurement of the droplet size distributions. The spray characteristics are quantified by the investigation of Deirmenjian's modified gamma distribution function. The distribution constant of the nozzle can be obtained as ${\alpha}=1$ and ${\gamma}=5.2$. The generalized equation of the optical depth related with the droplet size distribution is introduced. These results will be applicable to the analysis of the design condition of the water curtain nozzle.

Bacterial Regrowth in Water Distribution Systems and Its Relationship to the Water Quality: Case Study of Two Distribution Systems in Korea

  • Yoon, Tae-Ho;Lee, Yoon-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.262-267
    • /
    • 2004
  • This study was done to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems, which belongs to both K and Y water treatment plant of S city in Korea. The data analyzed in the distribution systems show that the free chlorine residuals decreased from 0.10 to 0.56 mg/l for K, and 0.51 to 0.78 mg/l for Y. The decay of free chlorine is clearly higher in both March and August than in January. The HPC in the distribution systems are ranged from 0 to 40 cfu/ml for K, 0 to 270 cfu/ml for Y, on $R_2$A medium. In particular, its level is relatively high at the consumer's ground storage tanks, taps, and the point-of-end area of Y. The predominant genera that were studied in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increases in the end-point area. Most of them are either encapsulated cells or of Gram-positve cocci. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from the water treatment plants, along with a greater diversity and a higher level of heterotrophic bacteria, due to the significant decay of free chlorine residuals.

Analysis of Agricultural Water Distribution Systems for the Utilization of Water-Demand-Oriented Water Supply Systems (물수요 중심 용수공급시스템 활용을 위한 국내 농업용수 공급체계 분석)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.2
    • /
    • pp.139-147
    • /
    • 2013
  • This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.

  • PDF