• Title/Summary/Keyword: Water cycle area ratio

Search Result 35, Processing Time 0.031 seconds

An Assessment of Urban Water Cycle in Changwon-si Using GIS-based Water Cycle Area Ratio (GIS 기반의 물순환 면적률을 활용한 창원시 도심지역의 물순환성 평가)

  • Song, Bonggeun;Park, Kyunghun;Lee, Taeksoon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.5
    • /
    • pp.397-408
    • /
    • 2013
  • The purpose of this study is to analyze water cycle area ratio and spatial evaluation of water cycle in urban area of Changwon-si, Gyeongsangnam-do. Water cycle area ratio are analyzed by using spatial data of land-cover and land-use, and Hot spot analysis of GIS program was used for spatial evaluation of water cycle. The results are as below. Firstly, the high water cycle area ratio areas were forests, parks, and rivers, but urban areas covered asphalt and concrete were low under 40%. Public institutions and co-residential of urban areas were higher than others because of high area ratio of pervious land-cover. Spatial evaluation of water cycle was analyzed to vulnerable areas there are dense residential and commercial area. These areas are really occurring frequently flooding and immersion, therefore, is required water management facilities and improvement of land-cover from impervious to pervious. In the future, it will require additionally analysis of water cycle area ratio supplemented data of water management facility and ground water.

Development of calculating daily maximum ground surface temperature depending on fluctuations of impermeable and green area ratio by urban land cover types (도시 토지피복별 불투수면적률과 녹지면적률에 따른 지표면 일최고온도 변화량 산정방법)

  • Kim, Youngran;Hwang, Seonghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.163-174
    • /
    • 2021
  • Heatwaves are one of the most common phenomena originating from changes in the urban thermal environment. They are caused mainly by the evapotranspiration decrease of surface impermeable areas from increases in temperature and reflected heat, leading to a dry urban environment that can deteriorate aspects of everyday life. This study aimed to calculate daily maximum ground surface temperature affecting heatwaves, to quantify the effects of urban thermal environment control through water cycle restoration while validating its feasibility. The maximum surface temperature regression equation according to the impermeable area ratios of urban land cover types was derived. The estimated values from daily maximum ground surface temperature regression equation were compared with actual measured values to validate the calculation method's feasibility. The land cover classification and derivation of specific parameters were conducted by classifying land cover into buildings, roads, rivers, and lands. Detailed parameters were classified by the river area ratio, land impermeable area ratio, and green area ratio of each land-cover type, with the exception of the rivers, to derive the maximum surface temperature regression equation of each land cover type. The regression equation feasibility assessment showed that the estimated maximum surface temperature values were within the level of significance. The maximum surface temperature decreased by 0.0450℃ when the green area ratio increased by 1% and increased by 0.0321℃ when the impermeable area ratio increased by 1%. It was determined that the surface reduction effect through increases in the green area ratio was 29% higher than the increasing effect of surface temperature due to the impermeable land ratio.

Assessment of Flooding Vulnerability Based on GIS in Urban Area - Focused on Changwon City - (GIS 기반의 도시지역 침수 취약성 평가 - 창원시를 대상으로 -)

  • Song, Bong-Geun;Lee, Taek-Soon;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.129-143
    • /
    • 2014
  • The purpose of this study is to evaluate flooding vulnerability considering spatial characteristics focused on Changwon-si, Gyeongsangnam-do. Assessment Factors are water cycle area ratio, surface runoff, and precipitation. And construction of assessment factors and vulnerability was analyzed by GIS program. Water cycle ratio and surface runoff were vulnerable in urban area. Precipitation was often distributed in agriculture of the northern region. Results of flooding vulnerability were low in agriculture and forest of the northern region. In contrast, urban area was high because there has covered impervious land cover. Analytical results of flooding vulnerability density using hotspot spatial cluster analysis were high in urban area. And these areas were situated in down stream so flooding were generated. Therefore, flooding vulnerability assessment of this study can help for selecting construction sites of pervious land cover and rainwater management facilities in urban and environmental planning.

Estimation of evapotranspiration change due to the 2019 April Gangwon-do wildfire using remote-sensing data

  • Kim, JiHyun;Sohn, Soyoung;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.4-4
    • /
    • 2020
  • Three wildfires severely damaged local towns and forests in Gangwon-do, South Korea in 2019 April 4-5. Local hydrological regime could be greatly altered by the wildfires, therefore it is important to assess its damage (e.g. area and severity) and also resultant changes in hydrological fluxes. We retrieved the Normalized-Burned Ratio (NBR) index using remote-sensing data (Moderate Resolution Imaging Spectroradiometer (MODIS) 500-m 8-day surface reflectance data), and delineated the damaged-area based on the difference in the NBR (dNBR) before and after the wildfires. We then estimated changes in the annual evapotranspiration (AET) in 2019 using the MODIS evapotranspiration data (500-m 8-day). It was found that the damaged-area of the three wildfires was 29.50 km^2 in total, which take up 1.00-6.19% area of five catchments. It was estimated that the AET would be decreased as 0.05-1.56% over those five catchments, as compared to the pre-fire AET (2004-2018). The impact of the wildfires on the catchment AET was less severe than expected (i.e. up to 1.56%) mostly because two big wildfires were distributed across two catchments respectively (i.e. four catchments for the two wildfires) and the other wildfire was small and not severe. This study highlights the importance of assessing the area and severity of a wildfire when estimating its impact on the local hydrological cycle.

  • PDF

Assessment of Water Circulation and Hydro-characteristics with LID techniques in urbanized areas (도시지역에 적용된 LID 기법의 강우시 수문특성 및 물순환 평가)

  • Choi, Hyeseon;Hong, Jungsun;Jeon, Minsu;Geronimo, Franz Kevin;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.191-198
    • /
    • 2019
  • High impervious surfaces increase the surface runoff during rainfall and reduces the underground infiltration thereby leading to water cycle distortion. The distortion of water cycle causes various urban environmental problems such as urban flooding, drought, water pollutant due to non-point pollution runoff, and water ecosystem damage. Climate change intensified seasonal biases in urban rainfall and affected urban microclimate, thereby increasing the intensity and frequency of urban floods and droughts. Low impact development(LID) technology has been applied to various purposes as a technique to reduce urban environmental problems caused by water by restoring the natural water cycle in the city. This study evaluated the contribution of hydrologic characteristics and water cycle recovery after LID application using long-term monitoring results of various LID technology applied in urban areas. Based on the results, the high retention and infiltration rate of the LID facility was found to contribute significantly to peak flow reduction and runoff delay during rainfall. The average runoff reduction effect was more than 60% at the LID facility. The surface area of the LID facility area ratio(SA/CA) was evaluated as an important factor affecting peak flow reduction and runoff delay effect.

Analysis on Water Retention Rate according to Water Cycle Characteristics in Jeju Gotjawal Forest (제주 곶자왈 산림의 물순환 특성에 따른 수원함양률 분석)

  • Jaehoon Kim;Honggeun Lim;Hyung Tae Choi;Qiwen Li;Haewon Moon;Hyungsoon Choi
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1013-1025
    • /
    • 2022
  • This study was carried out to analyze water cycle characteristics and evaluate water retention function in Jeju Gotjawal forest from 2013 to 2017. The average ratio of throughfall, stemflow, interception loss in Seonhul Gotjawal (SH) and Cheongsu Gotjawal (CS) was 43.1%, 15.8%, and 41.1%, respectively. Rainfall-throughfall, rainfall-stemflow, and rainfall-interception loss were expressed as linear regression equation (p<0.001). The comparison results showed that SH was higher than CS (p<0.05), indicating that the canopy area had an important effect on the difference in stand structure. The average water resources retention rate of the Gotjawal region was 41.9%, which is similar to the total water resources retention rate (40.6%) of Jeju Special Self-Governing Province (JSSGP). Currently, the development of Gotjawal is in progress in JSSGP. The development of Gotjawal will lead to a decrease in the water resources retention rate due to changes in the surface environment such as an increase in impervious areas, which will affect the total groundwater content of JSSGP. Therefore, the conservation of the Gotjawal area is judged to be very important from the point of view of water conservation.

Effects of porous pavement on runoff reduction in Boguang subcatchment (투수성 포장도로 도입을 통한 보광배수유역 유출량 저감효과 검토)

  • Jung, Jiyun;Lee, Gunyoung;Ryu, Jaena;Ohe, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.251-259
    • /
    • 2013
  • Among various Green Infrastructure measures for urban stormwater management, effects of porous pavement were quantitatively examined in terms of hydrological cycle. Different scenarios for porous pavement were introduced on a SWMM model and the effects were compared and analysed using discharge hydrographs. Two types of pavements having different runoff coefficients (0.05 & 0.5) were introduced to cover different ratio of entire road areas (100 %, 77.5 % and 40.4 %) and these made up in total 6 different scenarios. Total runoff volume was reduced and peak flow was significantly decreased by applying the porous pavement. The highest reduction for total runoff was shown from S-6(covering area: 100 %, runoff coefficient: 0.05) as 19 % followed by S-5(covering area: 77.5 %, runoff coefficient: 0.05, 16 %), while that of S-2(covering area: 40.4 %, runoff coefficient: 0.05) and S-1(covering area: 40.4 %, runoff coefficient: 0.5) were the lowest with 8 % and 5 %. This proved that the application of porous pavement would improve urban hydrological cycle.

Analysis of Hydrologic Cycle and BOD Loads Using HSPF in the Anyancheon Watershed (HSPF 모형을 이용한 안양천 유역의 물순환 및 BOD 부하량 분석)

  • Lee, Kil-Seong;Chung, Eun-Sung;Lee, Joon-Seok;Hong, Won-Pyo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.585-600
    • /
    • 2007
  • The hydrologic cycle and BOD pollutant loads of all sub-watersheds were analyzed using HSPF (Hydrological Simulation Program-Fortran). At first, sensitivity analyses to water quantity (peak discharge and total volume) and quality (BOD peak concentrations and total loads) were conducted and some critical Parameters were selected. For more precise simulation, the study watershed was divided into four parts according to the landuse characteristics and used climate data and so calibrated and verified respectively. It was found that as the urban area ratio increases in the downstream direction, baseflow decreases (11.1 % $\rightarrow$ 5.0%) and the ratio of direct runoff volume(42.5 % $\rightarrow$ 56.9 %), BOD concentration (3.3 mg/L $\rightarrow$ 15.0 mg/L) and unit loads (55.4 kg/ha/year $\rightarrow$ 354.5 kg/ha/year) increase.

Nitrogen and Phosphorus Removal in Domestic Wastewater using SBR Process with Flow Changing Continuous Feed and Cyclic Draw (교대연속유입식 SBR 공정을 이용한 하수중의 질소 및 인 제거)

  • Seo, In-seok;Kim, Hong-suck;Kim, Youn-kwon;Kim, Ji-yeon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • A continuous feed and cyclic draw SBR process was developed to overcome flow rate fluctuation and to maximize organic matters utilization efficiency for nitrogen and phosphorus removal. The developed SBR process was operated with two parallel reactors. Influent was supplied to one reactor which was not obligately aerated. At the same time, the other reactor was just aerated without supplying influent. In addition this mode was changed periodically. Cycle time was 6hr and aeration time ratio($t_{aer}/t_{total}$) was 0.33, respectively. $COD_{cr}$ and SS removal efficiencies of 95% or higher were achieved. Nitrogen removal was so greatly influenced by influent $COD_{cr}/T-N$ ratio. At influent $COD_{cr}/T-N$ ratio of 5.7, removal efficiencies of ammonia-N, T-N and T-P were 96%, 78% and 55%, respectively. Influent $COD_{cr}/T-N$ of 4 or higher ratio was necessary to achieve 60% or higher nitrogen removal. Organic matters of influent was efficiently utilized in denitrification reaction and consumed COD has a good correlation with removed T-N(about 6.5 mgCOD/mgTN). Continuous feed and cyclic draw SBR process could be one of alternative processes for the removal of nutrients in rural area where $COD_{cr}/T-N$ ratio was low and fluctuation of flow rate was severe.

The Forecasting Model of the Repair Cost in Apartment Housing - Focused roof water proofing and Elevator work - (공동주택 공종별 수선비용 예측모델 연구 - 옥상방수 공사와 승강기 공사를 중심으로 -)

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.63-68
    • /
    • 2015
  • Purpose: Most if buildings need various repair works for preventing or delaying the deterioration which gives rise to affect the living condition or function after constructed. Therefore, a long-term repair schedule should be planned and a repair cost is required. In this paper, it aimed at providing the statistical forecast model for a repair cost in roof water-proofing work and elevator work using statistical approach with three variables such as number of household, management area and a elapsed year. Data are collected in apartment housings which are located in Seoul area and conducted with interview and questionnaire sheet. Each analyzed work is divided into a partly work and fully work. Results of this study are shown that, first, the regression model takes a multiplying type like a Cobb-Douglas function and is changed into the log-linear type to include the three variable simultaneously. Second, the goodness-of-fit of the repair cost forecasting model has a good statistics in determinant's coefficient and Dubin-Watson value. Third, the management area is stronger factor than other the number of household and an elapsed year in roof water-proofing work and elevator work.