• Title/Summary/Keyword: Water control

Search Result 11,991, Processing Time 0.038 seconds

Water Treatment Process based on LonWorks System (수처리 공정상의 개방형 네트워크(LonWorks) 적용에 관한 연구)

  • Kim, S.H.;Kim, I.N.;Kwak, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2254-2258
    • /
    • 2003
  • In recent years, the case to install small water treatment facility to every local area has increased. A key issue in the successful implementation of the control systems for the water treatment plants is the choice of control architecture. Within the framework of distributed control system(DCS), this paper presents a new development of intelligent control module and its novel application to open control architecture for water treatment plants. This control system so called NCS(Network Based Control System) with standard networks system with LonTalks protocol of ANSI/EIA 709.1, regulatory control function and information dispatch function has suitable functionality to operate these distributed water treatment facility effectively. This paper describes the case where NCS is applied for the filters system in water treatment facility of Heong Sung area.

  • PDF

Water Quality Monitoring for Corrosion Control in Waterworks System (상수도관망 시스템의 부식제어를 위한 수질모니터링)

  • Lee, Hyun-Dong;Kwak, Phill-Jae;Lee, Ji-Eun;Kim, Yeong-Kwan;Han, Myung-Ho;Park, Young-Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.77-87
    • /
    • 2009
  • In existing systems, the best method inhibiting corrosion control in water distribution systems is to reduce water corrosiveness. Water corrosion can be decreased by controlling water quality through simple water treatment in treatment plants. On this research, we study the characteristics of tab water qualities in domestic areas, assessment of corrosive water quality and the method of water quality monitoring. This review presents the method of water quality monitoring which is the most applicable. Monitoring for corrosion control in waterworks system is the most proper method; It can prevent serious accidents economically and reduce civil appeals. Surely we should assess corrosive water quality in tab water, and introduce water treatment methods to control corrosive water quality before monitoring for corrosion. According to a lot of researches, it has been proved that simple water treatments can reduce the pipe corrosion. In this review we should indicate that we do not control of the corrosive water quality due to domestic conditions, we should monitor the water quality basically. Therefore, we recognize how the existing water quality can cause problems on pipeline corrosion, how to deal with it. Then it will be possible to apply water quality monitoring for corrosion control in water distribution system. Monitoring for corrosion control can be expressed by LI index, it is already known in literatures. This review presents more simple method than existing methods than existing ones we expect to apply these methods to SCADA in the future.

Application of nanofiltration membrane for the River Nile water treatment in Egypt: Case study

  • Jamil, Tarek S.;Shaban, Ahmad M.;Mansor, Eman S.;Karim, Ahmed A.;El-Aty, Azza M. Abd
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.233-243
    • /
    • 2018
  • In this manuscript, $35m^3/d$ NF unit was designed and applied for surface water treatment of the River Nile water. Intake of Embaba drinking water treatment plant was selected to install that unit at since; it has the lowest water quality index value through the examined 6 sites in greater Cairo area. The optimized operating conditions were feed and permeate flow, 40 and $7m^3/d$, feed pressure 2.68 bar and flux rate $37.7l/m^2h$. The permeate water was drinkable according to Egyptian Ministerial decree 458/2007 for the tested parameters (physic-chemical, heavy metals, organic, algal, bacteriological and parasitological). Single and double sand filters were used as pretreatment for NF membranes but continuous clogging for sand filters moved us to use UF membrane as pretreatment for NF membrane.

A Study on Development of Remote Control System for Watergate by Used Wireless Transfer Method (무선데이터 통신(2.4GHz대)을 이용한 수문 원격제어장치 개발에 관한 연구)

  • 이진구;김일수;박창언
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.237-241
    • /
    • 2003
  • The world's supply of water in all forms is enormous. However, only a tiny fraction of the planet's supply is available to us as fresh water, and that is distributed very unevenly. About 97% of oater volume is found in the oceans and is too salty for drinking, growing crops, and most industrial uses except cooling. In addition water supply crises in already-water-short-regions will intensify because population and industrialization increase. Today, remote monitoring and control systems are becoming the cost-effective management tools for almost all water user groups, including irrigators, water districts, municipal water suppliers, and wildlife management groups. This paper represents a new approach in the water-gate control using radio communication. The proposed device is simple in structure and suitable for implementation of water-gate control through the transceiver by radio communication. It was confirmed that the developed device was very efficient to control level of water-gate and to prove the up and down motion of water-gate through the LCD displayer.

  • PDF

An Introduction to Speed Control System of Small Steam Turbine for Feed Water Supply in Power Plant (발전소 급수펌프 구동용 소형 터빈 제어시스템 소개)

  • Choi, In-Kyu;Kim, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1603-1604
    • /
    • 2007
  • The load of power plants changes every from time to time according to which steam flow of boiler changes. the feed water control is very important for the power plant to be operated in its stability conditions. In case of circulation type boiler, the instability of feed water control leads to instability of drum level control. The higher level of drum water can induce bad quality steam to go into turbine which means the possibility of damage. The lower level of drum water can induce the tubes of boiler water wall to be overheated. In case of once through type boiler, the instability of feed water control leads to bad cooling of superheaters. The less the feed water flow is, the more heated the superheater is. It is necessary for the turbine driving feed water pump to be controlled for the optimal feed water flow in the large capacity power plant. The speed of turbine is controled for the feed water flow. By the way, the optimal control of steam valve is necessary for the speed control of turbine. Therefore, the various kinds of the steam valve structures are introduced in this paper

  • PDF

The Supply Water Algorithm for a Condensing Gas Boiler Control (콘덴싱가스보일러 제어를 위한 공급수알고리즘)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

Development of an Automatic Water Control System for Greenhouse Soil Water Content Management (시설재배 토양의 수분 조절을 위한 자동 수분제어시스템 개발)

  • Lee, D.H.;Lee, K.S.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.115-123
    • /
    • 2008
  • This study was conducted to develop an automatic soil water content control system for greenhouse, which consisted of drip irrigation nozzles, soil water content sensors, an on/off valve, a servo-motor assembly and a control program. The control logic adopted in the system was Ziegler-Nichols algorithm and rising time, time constant and over/undershoot ratio as control variables in the system was selected and determined by various control experiments to maintain small delay time and low overshoot. Based on the experimental results, it was concluded that the control system developed in the study could replace the unreliable conventional greenhouse soil water management.

A Study on Development of Remote Control Device for the Water Gate (수문을 위한 원격제어장치 개발에 관한 연구)

  • 이진구;김인주;정영재;손준식;김일수;박창언;성백섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1668-1671
    • /
    • 2003
  • Today, remote monitoring and control systems are becoming the cost-effetive management tools for almost all water user groups, including irrigators, water districts, municipal water suppliers, and wildlife management groups. This paper represents a new approach in the water-gate control using radio communication. The proposed device is simple in structure and suitable for implementation of water-gate control through the transceiver by radio communication. It was confirmed that the developed device was very efficient to control water-gate and to prove the up and down motion of water-gate through the LCD displayer

  • PDF

Present status and effective control measure of water-borne infectious diseases in Korea (수인성 전염병의 현황 및 효율적 관리)

  • 김호훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.41-49
    • /
    • 1994
  • Water- borne infectious diseases can be acquired by contact with contaminated water or by ingestion of contaminated water. There are many water- borne infectious agents such as bacteria, virus, and parasite. Among many of water- borne infectious diseases, health authorities of Korean government has particularly intensified to prevent and control typhoid fever(class I ), shigellosis(class I ), cholera(class I ), paratyphoid fever(class I), amebiasis(class II ) and leptospirosis(euivalent to class II ) under the communicable disease control law. Water- borne disease Prevention and control guideline itself has been also well provided by the health authorities. However, in practical public health point of view, there are still many problems remained to be solved out; no prospective investigation project to survey water borne infectious diseases under the national disease prevention and control programmes, incredible statistic data of annual notifiable disease report frequent appearance and varieties of drug resistance water- borne infectious agents, little cooperation and information- exchange system in between the related government authorities( the health authorities, the environment sanitation authorities and the food hygiene authorities) which should be closely collaborated, lack of health consciousness of the people, necessity of evaluation and Hndification on to the outcomes of performed health activities and programmes, neglect activities for water quality investigation, shortage of expertise and human resources in the related field, and poor investment of the government budget to develope and improve public health and sanitation field. In order to prevent and control water- borne infectious diseases effectively, it is emphasized that all the above indicated should be considered and performed to improve under the national health and sanitation development programmes.

  • PDF

Security measures of Information and Communication infrastructure of Water Resources Field (댐·보 등 수자원분야 정보통신기반시설 보안대책)

  • Yu, Se-Hwan;Jang, Dong-bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1034-1037
    • /
    • 2013
  • ICT infrastructure is electronic control systems or communication network related to national security, public administration, defense, policing, finance. Water resources sector has been building a system of control that can be performed electronically, communications, management, energy, and other work-related. Water resources sector has been a paradigm shift in water management and the control system is integrated into a single network. The control system security vulnerabilities are exposed - other control networks, business networks, linking with outside agencies, etc. Cyber terrorist society can cause a huge mess economically, The importance of security for control systems is becoming. In this paper, ICT infrastructure - the water resources in the field of control systems will analysis security measures.

  • PDF