• Title/Summary/Keyword: Water compaction

Search Result 333, Processing Time 0.025 seconds

Compaction techniques and construction parameters of loess as filling material

  • Hu, Chang-Ming;Wang, Xue-Yan;Mei, Yuan;Yuan, Yi-Li;Zhang, Shan-Shan
    • Geomechanics and Engineering
    • /
    • v.15 no.6
    • /
    • pp.1143-1151
    • /
    • 2018
  • Loess often causes problems when used as a filling material in the construction of foundations. Therefore, the compaction technique, shear behavior, and bearing capacity of a filled foundation should be carefully considered. A series of tests was performed in this study to obtain effective compaction techniques and construction parameters. The results indicated that loess is strongly sensitive to water. Thus, the soil moisture content should be kept within 12%-14% when it is used as a filling material. The vibrating-dynamic combination compaction technique is effective and has fewer limitations than other methods. In addition, the shear strength of the compacted loess was found to increase linearly with the degree of compaction, and the soil's compressibility decreased rapidly with an increase in the degree of compaction when the degree of compaction was less than 95%. Finally, the characteristic value of the bearing capacity increased with an increase in the degree of compaction in a ladder-type way when the degree of compaction was within 92%-95%. Based on the test data, this paper could be used as a reference in the selection of construction designs in similar engineering projects.

The Use of Water Treatment Sludge as a Landfill Cover Material (정수장(淨水場) 슬러지의 매립장(埋立場) 복토재(覆土材)로의 활용(活用)에 관(關)한 연구(硏究))

  • Lee, Kee-chool;Oh, Joon-seong
    • Clean Technology
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • Dewatered sludge of 400,000t/y from water treatment plants in Korea is being disposed through landfill and ocean dumping. However, the disposal is posing more and more serious environmental problems at the same time not only because of landfill site shortage in municipal suburbs, but because of the concern it will contaminate the oceans. In this study, the research on utilizing the sludge dried by flash dryer as covering soil in the landfill sites was carried out to solve these problems on environmental affinity. Both dewatered and dried sludge were exposed to the natural condition and observed according to the atmospheric changes. An experiment of soil engineering characteristics of the dried sludge and tests on mixed sludge(silty sandy soil : dried sludge = 10:90 ~ 30:70) such as particle size distribution, liquid and plastic limit, moisture content, specific gravity and compaction test were carried out. According to the compaction test, the compaction was confirmed as the optimum water content ratio was observed in the condition of SM-silty sand of particle size distribution, NP of liquid and plastic limit, 101.4% of moisture content, 2.04~2.12 of specific gravity. The results showed that dried sludges mixed with at least 30% of natural soil could be used as daily covering soil in the landfill sites.

  • PDF

The study on the Crushability of Weathered Cranite Soils (화강암질 풍화토의 파쇄성에 관한 연구)

  • 도덕현;강우묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.2
    • /
    • pp.81-103
    • /
    • 1979
  • The weathered granite soil involves problems in its stability in soil structures depending upon the reduction of soil strength due to the water absorption, crushability, and content of colored mineral and feldspar. As an attemt to solve the problems associated with soil stability, the crushability of weathered granite soil was investigated by conducting tests such as compaction test, CBR test, unconfined compression test, direct shear test, triaxial compression test, and permeability test on the five soil samples different in weathering and mineral compositions. The experimental results are summarized as follows: The ratio of increasing dry density in the weathered granite soil was high as the compaction energy was low, while it was low as the compaction energy was increased. The unconfined compressive strength. and CBR value were highest in the dry side rather than in the soil with the optimum moisture content, when the soil was compacted by adjusting water content. However, the unconfined compressive strength of smples, which were compacted and oven dried, were highest in the wet side rather than in soil with the optimum moisture content. As the soil becomes coarse grain, the ratio of specific surface area increased due to increased crushability, and the increasing ratio of the specific surface area decreased as the compaction energy was increased. The highest ratio of grain crushability was attained in the wet side rather than in the soil with the optimum moisture content. Such tendency was transforming to the dry side as the compaction energy was increased. The effect of water on the grain crushability of soil was high in the coarse grained soil. The specific surface area of WK soil sample, when compacted under the condition of air dried and under the optimum moisture content, was constant regardless of the compaction energy. When the weathered granite soil and river sand with the same grain size were compacted with low compaction energy, the weathered granite soil with crushability had higher dry density than river sand. However, when the compaction energy reached to certain point over limitation, the river sand had higher dry density than the weathered granite soil. The coefficient of permeability was lowest in the wet side rather than in the optimum moisture content, when the soil was compacted by adjusting soil water content. The reduction of permeability of soil due to the compaction was more apparent in the weathered granite soil than in the river sand. The highly significant correlation coefficient was obtained between the amount of particle breakage and dry density of the compacted soil.

  • PDF

A Field Application of the Self-Compaction Concrete for Shrinkage Compensation (수축보상을 위한 자기충전 콘크리트의 현장적용)

  • Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.7-12
    • /
    • 2002
  • The purpose of this study is to design and to apply the self-compaction concrete mixture to field, having not only high strength but also compensation for shrinkage without thermal crack under 4 sides outer restraint of the member. In the experimental mix, replacement ratio of limestone Powder, CSA expansive additives, and unit water were selected as parameters, using portland blast-furnace slag cement. And, bleeding test, expansibility test, hydration heat analysis were performed. As a results, when Cement is replaced with 35% limestone Powder, 6% CSA expansive additives at unit water 175kg/$m^3$, demanded performances of fresh and hardened self-compaction concrete are accomplished in the field application.

  • PDF

Stability Assessment of the Concrete Faced Gravel Dam and Construction Management for Soil Compaction using GPS system (콘크리트 표면 차수벽형 사력댐의 구조적 안정성 평가 및 GPS 다짐 시공관리)

  • In, Young-Gil;Yoo, Sang-Hwa;Chae, Kwang-Seok;Shin, Dong-Hoon;Seo, Seung-Cheol;Gu, Ja-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.26-43
    • /
    • 2010
  • To determine the effect of draining for the drainage layer in CFGD(Concrete Faced Gravel Dam) body, centrifuge model tests were performed. Also, soil compaction works are essential to construction of dams in order to avoid unexpected settlement of superstructures. Taking advantage of oscillating accelerometer, this research was made to complement existing methods for assessment of soil stiffness. In order to examine the validity of compaction-degree suggested in the study, tests on vibration characteristics using accelerometers was also performed.

  • PDF

Application of WCT (Wet Compaction Test) to Mixed Fiber Furnishes (Wet compaction test를 이용한 혼합지료의 적용)

  • Seo Yung B.;Lee Chun Han
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.4 s.112
    • /
    • pp.8-17
    • /
    • 2005
  • WCT (Wet compaction test) is a new fiber evaluation method developed recently by Seo and its test results can be used as a predictor for pulp quality and its paper property Bleached chemical pulps (SwBKP, HwBKP), recycled pulp (OCC), and mechanical pulp (BCTMP) were used for the furnishes to be tested by WCT We compared the WCT results to conventional fiber evaluation tests such as WRV (Water Retention Value), free ness, and fiber length in this study, and found that WCT always gave better regression coefficients in relation to pulp quality (drainage), and paper properties (density, tensile, tear, and burst strength). WCT may be used on-line in papermachine.

Study on Characteristics of Soil Compaction using Accelerometer (진동가속도계를 이용한 지반다짐 특성 연구)

  • Chae, Kwang-Seok;Shin, Dong-Hoon;Im, Eun_Sang;Gu, Ja-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1397-1403
    • /
    • 2008
  • Soil compaction works are essential to construction of dams, breakwaters and roads in order to avoid unexpected settlement/deformation of superstructures. Taking advantage of oscillating accelerometer, this research was made to complement existing methods for assessment of soil stiffness. In order to examine the validity of compaction-degree suggested in the study, tests on vibration characteristics using accelerometers was also performed. Test results for sand and gravel mixtures and Korean standard sands were compared and evaluated by conventional assessment methods under varying conditions as of input frequency, size of loading plate and relative density.

  • PDF

A Study on the Mix Design of the Self-Compaction Concrete for the LNG Tank (LNG Tank용 자기충전 콘크리트의 배합설계에 관한 연구)

  • Kim, Dong-Seok;Park, Sang-Joon;Won, Cheol;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.135-138
    • /
    • 2003
  • The purpose of this study was to design the self-compaction concrete mixture, having not only high strength but also compensation of shrinkage without thermal crack under 4 sides outer restraint of the member. In the experimental mix, replacement ratio of limestone Powder, CSA expansive additives, and unit water were selected as parameters, using portland blast-furnace slag cement. And, bleeding test, expansibility test, hydration heat analysis were performed. As a results, when 35% of limestone Powder, 6% CSA expansive additives are replaced at unit water 175kg/$\textrm{m}^3$, demanded performances of fresh and hardened self-compaction concrete are accomplished.

A Study on the Mix Design of the Self-Compaction Concrete for the LNG Tank (LNG Tank용 자기충전 콘크리트의 배합설계에 관한 연구)

  • Kim, Dong-Seok;Park, Sang-Joon;Won, Cheol;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.85-88
    • /
    • 2004
  • The purpose of this study was to design the self-compaction concrete mixture, having not only high strength but also compensation of shrinkage without thermal crack under 4 sides outer restraint of the member. In the experimental mix, replacement ratio of limestone Powder, CSA expansive additives, and unit water were selected as parameters, using portland blast-furnace slag cement. And, bleeding test, expansibility test. hydration heat analysis were performed. As a results, when 35% of limestone Powder, 6% CSA expansive additives are replaced at unit water 175kg/$\textrm{m}^3$, demanded performances of fresh and hardened self-compaction concrete are accomplished.

Effect of Particle Breakage on Compaction and Thermal Resistivity of Concrete-based Recycled Aggregates (콘크리트 재생 순환골재의 파쇄 효과에 따른 다짐 및 열저항 특성 연구)

  • Kang, Sungchul;Kim, Gyeonghun;Wi, Jihae;Ahn, Taebong;Lee, Dae-Soo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.10
    • /
    • pp.17-28
    • /
    • 2015
  • The strict regulations on eco-friendly construction and the significant reduction of natural aggregate resources have raised public concerns on the utilization of recycled aggregates for backfilling a power transmission pipeline trench. In this paper, the particle breakage of concrete-based recycled aggregates and river sand has been experimentally studied during the standard compaction test. The applied compaction energy does not significantly break the river sand particles down, and thus causes no change in the compaction curve, thermal resistivity, and particle gradation characteristics. On the other hand, considerable particle breakage was observed in case of the three recycled aggregates. Such particle breakage leads to enhancing compaction effort, reducing thermal resistivity, and changing particle gradation curve with finer particles that are broken during the first compaction. In addition, particle breakage is more dramatic in lower water contents because pore water may damp down the compaction energy.