• 제목/요약/키워드: Water calorimeter

검색결과 91건 처리시간 0.034초

Establishment of calculation methodology and thermal analysis for the development of a water calorimeter

  • Kang, M.Y.;Kim, Junhyuck;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2620-2629
    • /
    • 2020
  • As an early stage in the development of a water calorimeter, this study established a computer simulation methodology for analyzing the thermal behavior of a water calorimeter based on radiation transport and energy deposition. As a result, this study developed a method wherein the energy deposition distribution, which is obtained by applying Monte Carlo methods in water calorimeters, is directly used as a heat source for the thermal analysis model. Based on the proposed method, heat transfer in a water vessel and the effect of thermistor self-heating were analyzed. Through an analysis of the water velocities with and without a water vessel, it was found that a water vessel can serve as a convection barrier. Furthermore, it was confirmed that when considering thermistor self-heating, the water temperature change at the thermistor location is 0.219 mK higher compared to that when the thermistor was not considered. Therefore, thermistor self-heating must be considered to analyze the thermal behavior of a water calorimeter more accurately.

발열량 측정장치 개발에 관한 연구 (An Experimental Study on the Developement of Bomb Calorimeter)

  • 김형만;손영목;이동제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.60-65
    • /
    • 2001
  • Bomb calorimeter was developed for measuring the calorific value of combustible matter such as wastes. The calorimeter consist of bomb, stirred-water type bucket, thermometer and ignition circuit. Operation and performance of the calorimeter have been tested experimentally. In the present study, calorific values of light oil, lamp oil and bunker C oil is measured using the bomb calorimeter. Mass of the sample is fixed at lg, and oxygen pressure in the bomb is used as an experimental parameter. Sample in the oxygen bomb is burned with electrically heated Ni-Cr wire of 100mm in length, and temperature of water in the bucket become increased by $5^{\circ}C$ during about 30min. Calorific value of the sample is calculated with the temperature difference of water. Combustion tests, such as the record of temperature history and the inspection of remnants, are performed at 4, 6, 8 and 10 atm of the oxygen pressure. From the test results, oxygen pressure in the bomb must be over 10atm for complete combustion.

  • PDF

발열량 측정장치 개발에 관한 연구 (An Experimental Study on the Developement of Bomb Calorimeter)

  • 이동제;손영목;강한샘;김형만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제22회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.23-30
    • /
    • 2001
  • Bomb calorimeter was developed for measuring the calorific value of combustible matter such as wastes. The calorimeter consist of bomb, stirred-water type bucket, thermometer and ignition circuit. Operation and performance of the calorimeter have been tested experimentally. In the present study, calorific values of light oil, lamp oil, benzoic acid, ethyl alcohol and methyl alcohol is measured using the bomb calorimeter. Mass of the sample is fixed at 19, and oxygen pressure in the bomb is used as an experimental parameter. Sample in the oxygen bomb is burned with electrically heated Ni-Cr wire of 100mm in length, and temperature of water in the bucket become increased by $2{\sim}5^{\circ}C$ during about 30min. Calorific value of the sample is calculated with the temperature difference of water. Combustion tests, such as the record of temperature history and the inspection of remnants, are performed at 6, 8 and 10 atm of the oxygen pressure. From the test results, oxygen pressure in the bomb must be over 10atm for complete combustion.

  • PDF

열펌프 열량계 구조 및 성능 특성 연구 (The Study on the Structure and Performance of Heat Pump Calorimeter)

  • 박승병;이상혁;최진일;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.7-13
    • /
    • 2015
  • The efficiency, reliability and performance of any heat pump unit can only be ascertained after it has been tested and rated. For this reason, specific facilities, equiped with testing plants are built. Heat pump calorimeter is the facilities used by most of these testing facilities in their rating and certification process. The ultimate function of calorimeters is to, control and maintain the constant standard test conditions (indoor/outdoor entering temperatures and flow rate etc) during testing period. In this study, the test standards of heat pump unit and the structure of the calorimeter are surveyed. In addition, this study analyzes the total energy consumption of a water to water heat pump calorimeter. Heat pump calorimeter consumed much energy to excute the heat pump tests. The energy consumption of the calorimeter was higher than the heat pump unit, and it was increased as the heat pump unit capacity decreased.

전자 소자를 이용한 연소열 측정 (Measurement of Calorific Value Using Flame Calorimeter)

  • 임기원;전진용;이병준
    • 한국연소학회지
    • /
    • 제15권3호
    • /
    • pp.40-47
    • /
    • 2010
  • Calorific value of mixed gas, like liquefied natural gas (LNG), is strongly depends on its compositions which are affected by the mining place and producing time. The variation in calorific value have an direct influence on the combustion characteristics and performances of boiler, burner, vehicle, power plants etc. Thus, developing experimental method to measure exact calorific value is becoming an issue in the related industrial fields. Flame calorimeter is developed to get calorific value at the dynamic equilibrium state using electric substitution method. Refrigerant-11 carries heat from combustor and/or heater to the Peltier elements which pumped it out to the cooling water. It is found out that error in the measured calorific value of methane is 2.86% compared with the theoretical one. Developed design technique and the experimental data will be applied to design the national standard gas calorific value measuring apparatus.

A STUDY OF GEL STRUCTURE IN THE NONIONIC SURFACTANT / CETOSTEARYL ALCOHO L/ WATER TERNARY SYSTEMS BY DIFFERENTIAL SCANNING CALORIMETER

  • Yoon, Moung-Seok;Chung, Youn-Bok;Kun Han
    • 대한화장품학회지
    • /
    • 제26권1호
    • /
    • pp.213-232
    • /
    • 2000
  • Cetostearyl alcohol has been incorporated into cosmetic or pharmaceutial emulsions to give them an appropriate consistency and a long term stability. It is well known that cetostearyl alcohol forms a gel phase with a nonionic surfactant in an aqueous system, and the properties of the gel phase depend on several factors such as the ratio of fatty alcohols. The aim of the present Paper is to investigate the effect of the structural difference of the lipophilic part of surfactants on the stability of the gel phase in the nonionic surfactant / cetostearyl alcohol / water ternary systems using differential scanning calorimeter. It is concluded that the gel phase formed by the surfactant having the bended alkyl chain is more unstable than that formed by the case of the straight alkyl chain, and we discussed the reason why the former is more unstable after long term storage by means of the measurements of the ${\Delta}$H.

  • PDF

추력 2톤급 축소형 칼로리미터 개발 (Development of 2-ton thrust-level sub-scale calorimeter)

  • 조원국;류철성;정용현;이광진;김승한;이수용
    • 한국항공우주학회지
    • /
    • 제33권3호
    • /
    • pp.107-113
    • /
    • 2005
  • 고성능 로켓엔진 연소기의 벽면 열유속 측정을 위하여 추력 2톤급 칼로리미터를 개발하였으며 고온에서 전열특성과 강도특성이 뛰어난 크롬동합금을 연소실 내벽 소재로 적용하였다. 전체적인 냉각성능은 경험식을 기반으로 하는 1차원 해석으로 확인하였으며 국부적인 냉각성능은 3차원 CFD 해석으로 검증하였다. 연소압 53 bar 조건에서 노즐목에서의 열유속은 43 $MW/m^{2}$ 으로 예측되었다. 연소실의 구조적인 안전성은 150 bar에서 2차원 해석과 시편에 대한 변형실험으로 확인하였다. 최종적으로 상온 150 bar에 대한 가압실험으로 안전성을 검증하였고 개발된 칼로리미터와 동일한 냉각성능을 갖는 시험용 노즐을 사용하여 예비시험을 수행하였다. 노즐목에서 측정된 열유속이 설계값에 비하여 10% 높았음에도 연소실 내벽에 열손상은 발생하지 않았다.

KSR-III 축소형 연소기의 열유속 평가 (Heat Flux Evaluation of KSR-III Sub-scale Chamber)

  • 조원국;문일윤;김종규
    • 한국추진공학회지
    • /
    • 제8권1호
    • /
    • pp.81-84
    • /
    • 2004
  • KSR-III 축소형 연소기를 원형으로 하는 8채널 형태의 물냉각 칼로리미터를 설계/제작하였다. 설계는 1차원 경험식을 이용하였으며 시험전에 3차원 전산유동해석을 수행하여 연소시험을 위한 냉각 조건의 안전성을 확인하였다. 탄소침착물의 단열효과를 고려할 경우 노즐목 부근에서 예측한 열유속이 정확성을 가지는 것으로 확인되었으며 연소실 부근에서는 상대적으로 큰 오차를 보였다.

마이크로캡슐 잠열 축열재 혼합수의 열물성에 관한 연구 (A Study on Thermo-Physical Properties of Microencapsulated Phase Change Material Slurry)

  • 임재근;최순열;김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.962-971
    • /
    • 2004
  • This paper has dealt with thermo-physical properties of microencapsulated phase change material slurry as a latent heat storage material having a low melting point. The measured results of the thermo-physical properties of the test microencapsulated phase change material slurry, those are, density, specific heat, thermal conductivity and viscosity, were discussed for the temperature region of solid and liquid phases of the dispersion material (paraffin). The measurements of these properties of microencapsulated phase change material slurry have been carried out by using a specific-gravity meter, a water calorimeter, a differential scanning calorimeter(DSC), a transient hot wire method and rotating type viscometer, respectively. It was clarified that the additional properties law could be applied to the estimation of the density and specific heat of microencapsulated phase change material slurry and also the Euckens equation could be applied to the estimation of the thermal conductivity of this slurry.

미립 피복 상변화 물질의 상변화 온도에 대한 연구 (Phase-change Temperature of Micro-encapsulated Phase-change Material)

  • 최은수
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.168-174
    • /
    • 2002
  • In order to obtain a new heat transfer fluid having a high thermal capacity, micro-capsules of a phase-change material can be a successful candidate to be added into water. In this study, 25, 50, 100, and $200\mu$m diameter micro-encapsulated Lauric acids were tested by a differential scanning calorimeter. The Lauric acid itself had a single freezing curve, but the micro-encapsulated Lauric acid had double freezing curves. The second freezing dominated for $25\mu$m diameter Lauric acids. But the first freeing energy became big as the size of the capsule increased.