Effect of Organic Materials in Water Treatment by Hybrid Module of Multi-channel Ceramic Microfiltration and Activated Carbon Adsorption

  • Park, Jin-Yong;Lee, Sang-Min
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.21-28
    • /
    • 2009
  • We investigated the effect of organic materials on membrane fouling in advanced drinking water treatment by a hybrid module packed with granular activated carbon (GAC) outside multi-channel ceramic microfiltration membrane. Synthetic water was prepared with humic acid and kaolin to simulate natural water resouces consisting of natural organic matter and inorganic particles. Kaolin concentration was fixed at 30 mg/L and humic acid was changed as 2~10 mg/L to inspect the effect of organic matters. Periodic back-flushing using permeate water was performed for 10 sec per filtration of 10 min. As a result, both resistance of membrane fouling (Rf) and permeate flux (J) were influenced highly by concentration of humic acid. It proved that NOM like humic acid could be an important factor on membrane fouling in drinking water treatment. Turbidity and UV254 absorbance were removed up to above 97.4% and 59.2% respectively.

일반 유기물 항목과 분광특성을 이용한 한강수계 내 난분해성 물질 지표 제시 (Development of Estimation Indices for Refractory Organic Matter in the Han-River Basin using Organic Matter Parameters and Spectroscopic Characteristics)

  • 이보미;이태환;허진
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.625-633
    • /
    • 2011
  • A long-term water quality monitoring in the Han River Basin reveals a consistent increasing trend for the concentration of refractory organic matter (R-OM) in major monitoring sites of the watershed. Because the determination of R-OM concentrations typically requires a long time of microbial incubation, it is essential to present the estimation indices for R-OM for an efficient watershed management. In this study, a number of surface water samples were classified into three groups, each of which were collected from Lake Paldang, rivers at rain and non-rain events, respectively. The corresponding R-OM concentrations were correlated with biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) concentrations as well as ultraviolet and fluorescence intensities of the filtered samples. Among the traditional organic matter parameters, TOC exhibited the highest correlation coefficient with the R-OM concentrations regardless of the types of the sample groups. The equations for conversing TOC into R-OM concentrations were finally suggested as $0.43{\times}TOC+1.12$, $0.44{\times}TOC+0.61$, $0.24{\times}TOC+1.28$ for river samples at rain and non-rain events, and lake samples, respectively. TOC-BOD(C), the values of the TOC concentrations subtracted by carbon-converted BOD concentrations, was a good index for estimating the absolute concentrations of R-OM. UV absorbance at 254 nm was well correlated with R-OM concentrations of river samples while fluorescence intensities at 350 nm showed an excellent relationship with R-OM concentration of the lake samples. Our results suggests that simple spectroscopic parameters could be applied for in-situ monitoring tool techniques in watersheds.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • 제28권4호
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

화학적 산화법에 의한 부식산의 분해처리 기술에 관한 연구(II) - 오존처리에 따른 분해특성 분석 - (Characterization of Humic Acid in the Chemical Oxidation Technology(II) - Characteristics by Ozonation -)

  • 이동석;정영림
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.241-249
    • /
    • 2000
  • 본 연구는 수질계의 용존 유기 탄소화합물의 주성분인 부식산을 화학적 산화방법 중 오존처리를 사용하여 $UV_{254}$ 흡광도, TOC, $^{13}C-NMR$, 한외여과법 등을 이용하여 오존 처리후의 특성 변화를 조사하였으며, 오존 산화물의 GC/MS 분석을 통하여 포름알데히드, 아세트알테히드, 아세톤, 글리옥살 및 메틸글리옥살 등의 생성을 확인하였다. $UV_{254}$ 흡광도와 TOC의 측정결과 부식산 농도 20, 100ppm 모두 오존처리시간 20분 이내에서 80%의 색도 감소율과 30분 이내에서 40-50%의 TOC 제거율을 나타냈고, 그 이후의 처리시간에서는 일정한 색도 감소율 및 제거율을 나타냈다. $^{13}C-NMR$, 한외여과법을 통한 실험결과, 오존처리에 의해 고분자량의 부식산이 산화, 분해됨으로서 알데히드, 카르복실산 등이 풍부한 저분자량의 단위체로 나뉘어지며 생물학적 분해가 용이한 지방족 탄소가 풍부한 구조로 전환됨를 확인하였다.

  • PDF

분광특성을 이용한 하·폐수시료 내 난분해성 유기물 농도 및 분포 예측 (Predictation of the Concentrations and Distributions of Refractory Organic Matters in Wastewater using Spectroscopic Characteristics)

  • 이보미;박민혜;이태환;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.560-567
    • /
    • 2009
  • Treated or untreated wastewater may be a major source of refractory organic matters (R-OM) in drinking water sources. For this study, spectroscopic characteristics of wastewater OM were investigated using the samples from 20 wastewater treatment plants, which are located at the upstream of the lake Paldang, to suggest a estimate index for R-OM in wastewater. R-OM was quantified by measuring total organic carbon (TOC) concentration of the wastewater samples remaining after 28-day dark incubation. Among the traditional OM indices such as chemical oxygen demand (COD) and initial TOC, CODMn showed the lowest correlation coefficients with R-TOC of the samples. The ratios of carbonaceous biochemical oxygen demand (CBOD) to $COD_{Cr}$ had a better correlation with the percent distribution of R-OM than $BOD/COD_{Cr}$ ratios. terrestrial humic-like fluorescence (THLF) exhibited the highest correlation coefficient with R-TOC among the indices obtained from the synchronous fluorescence spectra of the samples. Milori index, one of the humification indices, showed a good correlation with the percent distribution of wastewater. This study demonstrated that fluorescence properties might be a better indices to estimate the concentrations and the distributions of wastewater OM compared to the specific UV absorbance (SUVA) values. Some useful formulas based on OM spectroscopic characteristics were finally suggested to predict R-OM in wastewater.

세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척 시 유기물의 영향 (Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of Organic Materials in $N_2$-back-flushing)

  • 박진용;박길용
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.203-211
    • /
    • 2009
  • 본 연구에서는 고도정수처리를 위하여 모듈 내부와 관형 세라믹 정밀여과막 외부 사이의 공간에 입상 활성탄(GAC)을 충전한 혼성 모듈을 사용하였다. 정수 원수 중의 자연산 유기물(NOM)과 미세 무기 입자를 대체하기 위해, 휴믹산(humic acid)과 카올린(kaolin) 모사용액을 대상으로 하였다. 혼성공정에서 막오염을 최소화하고 투과선속(J)을 향상시키기 위하여 10분 주기로 10초 동안 질소 역세척을 시행하였다. 그 결과, 휴믹산의 농도가 10 mg/L부터 2 mg/L로 단계적으로 변화시킴에 따라 막오염에 의한 저항($R_f$)이 감소하고 J가 증가하여 2 mg/L에서 가장 높은 총여과부피($V_T$)를 얻을 수 있었다. 한편, 탁도 및 $UV_{254}$ 흡광도의 처리효율은 각각 99.36% 및 97.19% 이상으로 우수하였으나, 휴믹산의 농도 10 mg/L에서 활성탄 주입 없이 정밀여과 단독으로 UV254 흡광도의 처리효율은 90.84%로 다소 감소하였다.

Preparation and Characterization of Hydrogels containing Silicone or Fluorine

  • Kim, Eui Seok;Shim, Sang-Yeon
    • 한국응용과학기술학회지
    • /
    • 제34권3호
    • /
    • pp.650-656
    • /
    • 2017
  • The water-swollen hydrogels containing silicone or fluorine were prepared by copolymerization of 2-hydroxy ethyl methacylate (HEMA) with 3-(trimethoxysilyl)propyl methacrylate(SM) or 2,2,2-trifluoroethyl acrylate(FA). When the content of SM or FA increased in copolymers, there was tendency of water absorbance to decrease, whereas contact angles to increase. The hydrogels containing FA showed 2 ~ 4% higher water content and 4 ~ 5% lower contact angles compared to that of SM. Tensile strengths decreased as the content of SM increased. However, FA exhibited strength of $2.2Mpa/cm^2$ which is similar to $2.3Mpa/cm^2$ of B. FA, which implies comparatively low adherence, hence, showed better protein resistance properties than SM-based hydrogel. The photo-polymerization was also applied instead of thermal polymerization to enhance the energy efficiency. As a result, the reaction yield reached over 95% within 1 minute.

Impact of Water Quality on the Formation of Bromate and Formaldehyde during Water Ozonation

  • Lee, Chung-Youl;Lee, Yoon-Jin
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.441-450
    • /
    • 2007
  • 본 연구는 humic acid 및 bromide를 함유한 상수 원수에 오존 처리를 수행함에 있어 수질 특성 및 공정조건에 따른 bromate 및 formaldehyde 의 생성을 고찰하였다 . 회분식 실험장치를 이용하여 오존의 주입농도, DOC 농도, bromide 농도, pH, 알칼리도 및 반응 시간을 변화시키면서 오존처리 시 생성되는 대표적인 부산물인 bromate 및 formaldehyde의 거동을 파악하였다. 본 연구에서 검토된 영향 인자 중 수중의 pH조건은 bromate 및 formaldehyde의 생성에 가장 중요한 인자로 나타났다. DOC(dissolved organic carbon) 농도가 증가할수록 bromate 생성은 감소하였고 formaldehyde 의 생성은 증가하였다. 오존처리를 통해 UV254 는 효율적으로 감소되었고, UV254의 감소율 및 오존 농도는 선형 관계를 나타냈다.

Real-time Spectroscopic Methods for Analysis of Organic Compounds in Water

  • Kim, Chihoon;Ji, Taeksoo
    • Current Optics and Photonics
    • /
    • 제3권4호
    • /
    • pp.336-341
    • /
    • 2019
  • This paper proposes an optical system where the organic compound content in water is determined by using an ultraviolet (UV) LED (280 nm) and photodetector. The results obtained by the proposed prototype LED spectroscopy system, which includes a single photodetector and two parallel sample holders, are calculated by applying partial least square regression; the values are highly correlated with the actual concentrations of potassium hydrogen phthalate solutions, with an adjusted coefficient of determination about 0.996. Moreover, the total organic carbon values derived from the UV-Vis spectrometer of real samples (lake, river and sea water) differed little from those obtained by the LED spectroscopy. We confirm that the fast, sensitive, and compact LED sensor system can be readily configured for real-time monitoring of organic compounds in water.

Skin depth profiling by using fiber optic probes in the near infrared

  • Woo, Young-Ah;jung, Suh-Eun;Kim, Hyo-Jin
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.218-218
    • /
    • 2003
  • Recently we showed the prototype portable device for the determination of human skin moisture by using near infrared spectroscopy. In order to optimize the acquiring condition of NIR spectrum of skin and control the target information of water depending the site such as epidermis and dermis, skin depth profiling was investigated changing the distance between illuminations and receiving of radiation in the terminal of fiber probe. The colleted light information could be controlled by changing the distance of the fiber optic probes. It was confirmed that the longer distance we used, the deeper site from the skin surface we could get information from in this study. Four kinds of probes with distances such as 0.03 mm, 0.1 mm, 0.5 mm, and 1.0 mm were used. In addition, the gap size from 0.3 mm to 3.0 mm was studied to control the intensity of water absorbance effectively and to avoid saturation of water absorption. We also investigated the reference materials depending the reflectance ratio for water absorption not to be saturated because of the strong absorptivity of water. Furthermore, spectroscopic information regarding free water and bound water around 1850 nm was investigated by using the different distance of fiber optic probes. This study would be great help to control the spectroscopic information of water to be measured depending the site where water exists.

  • PDF