• 제목/요약/키워드: Water Tank Test

검색결과 388건 처리시간 0.025초

A Study on Sensitivity Analysis of the Hydrodynamic Derivatives on the Maneuverability Prediction of KVLCC2 in Shallow Water by Model Test

  • Nguyen, Van Minh;Nguyen, Thi Thanh Diep;Yoon, Hyeon Kyu
    • 한국항해항만학회지
    • /
    • 제44권2호
    • /
    • pp.98-109
    • /
    • 2020
  • In recent years, there have been concerted efforts toward predicting ship maneuvering in shallow water since the majority of ship's accidents near harbors commonly occur in shallow and restricted waters. Enhancement of ship maneuverability at the design stage is crucial in ensuring that a ship navigates safely. However, though challenging, establishing the mathematical model of ship maneuvering motion is recognized as crucial toward accurately predicting the assessment of maneuverability. This paper focused on a study on sensitivity analysis of the hydrodynamic coefficients on the maneuverability prediction of KVLCC2 in shallow waters. Hydrodynamic coefficients at different water depths were estimated from the experimental results conducted in the square tank at Changwon National University (CWNU). The simulation of standard maneuvering of KVLLC2 in shallow waters was compared with the results of the Free Running Model Test (FRMT) in shallow waters from other institutes. Additionally the sensitivity analysis of all hydrodynamic coefficients was conducted by deviating each hydrodynamic derivative from the experimental results. The standard maneuvering parameters including turning tests and zig-zag maneuvers were conducted at different water depths and their effects on the standard maneuvering parameters were assessed to understand the importance of different derivatives in ship maneuvering in shallow waters.

KSR-III 추진기관 공급계 개발 (Development of KSR-III Propulsion Feeding System)

  • 이대성;조인현;정태규;강선일;김용욱;정영석;권오성;정동호;오승협
    • 한국추진공학회지
    • /
    • 제6권4호
    • /
    • pp.37-45
    • /
    • 2002
  • The development process of KSR-III propulsion feeding system is subscripted. The purpose of propulsion feeding system is to feed a certain amount of propellant from propellant tank to engine by the end of combustion. Pressure-fed liquid rocket, KSR-III has the unique characteristics of both pressure regulator and cavitation venturi as a passive flow control device. Main parameters of feeding system are confirmed by both water test and CFD(전산유체) technique. Flow control effect with venturi is confirmed by water test. Initial stabilization characteristic of pressure regulator is confirmed by real propellant test. And, to avoid the effect of resonance between rocket and feeding system, this article deal with POGO(포고) analysis to the feeding system.

인공위성 추진계통 관로내의 수격효과에 관한 실험적 연구 (An Experimental Study on Water-Hammer Effect for Spacecraft Propulsion System)

  • 권기철;이은상;박상민;강신재;노병준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.288-293
    • /
    • 2001
  • This paper presents the water-hammer effect due to the rapid opening and closing of isolation valve and thruster valve in the spacecraft propulsion system. The single propellant feed system was modeled to investigate the maximum peak pressure due to the water-hammer effect. The test parameters are tank supply pressure, shape and throat length of orifice and line length. Kerosene was used as the inert simulant propellant liquid instead of hydrazine. As downstream line length after isolation valve increased from 1.5 to 2.5m, the maximum line-filling water-hammer peak pressure decreased, but the average time interval between peak pressures increased. The maximum line-filling water-hammer peak pressure with orifice was lower than without orifice, and the maximum line-filling water-hammer peak pressure with orifice at the back of isolation valve was lower than with orifice in front of isolation valve. Without orifice, the maximum water-hammer peak pressure due to the rapid opening and closing of the thruster valve was about 126% of tank supply pressure. With orifice, it decreased. As orifice throat length increased, it decreased. The maximum water-hammer peak pressure due to the rapid closing of the thruster valve with converging-diverging orifice was lower than normal orifice. It was found that the orifice as a means of pressure drop was very effective to reduce the water hammer peak pressure at the thruster valve. The results of this study can be used for the design of spacecraft liquid propulsion feed system.

  • PDF

천연 수소 발생 광물 필터를 이용한 녹조 정화 시스템 (Green Purification System using Natural Hydrogen Generating Mineral Filter)

  • 권유지;박대겸
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.475-485
    • /
    • 2024
  • In many regions of Korea, including the Four Major Rivers, the seriousness of the problem of algal blooms due to eutrophication of water quality is being raised.In this study, in order to solve these social problems, we manufactured a filter using natural mineral fusion (red illite, zeolite, germanium ceramic, selenium ceramic, carbon ceramic) and independently developed a tank system for green algae experiments to observe and determine the stages of change in water quality. In order to study ways to improve water quality through quantitative analysis, 1 ton of severely polluted green algae water from the Nak dong River region was stored in a water tank and exposed to ultraviolet rays in the same environment as the Nak dong River. Then, the same environment as the Nak dong River was created. The results were derived from a 5-week water quality test. The results of this experiment confirmed that green-colored cyano bacteria were significantly reduced just by the turbidity results. The results were obtained through a request to the Korea Testing & Research Institute located in Changwon-si, Gyeong sang nam-do. CI-(chlorine ion) and NH3-N(ammonia nitrogen) had the effect of saving every week. The device used in this study was made of natural minerals free of heavy metals that are harmless to the human body and nature through long-term consideration and exploration to kill and prevent various strains living in water. Green purification system using natural hydrogen generating mineral filter were effective a non-chemical and physical methods. The results of this study are one way to contribute to the serious problems caused by green algae in many countries, and will contribute to the water quality environment by preventing the waste of environmental resources, improving the health of the people, and increasing the ability to purify environmental water quality at home and abroad.

터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구 (Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance)

  • 손동기;김춘택;윤민수;차봉준;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

부이 형상에 따른 부이줄 장력의 차이 (Difference of tension on mooring line by buoy type)

  • 이건호;김인옥;차봉진;정성재
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.233-243
    • /
    • 2014
  • The difference of mooring tension by type of buoy was investigated in the circulating water channel and the wave tank for deducting the most stable buoy from the current and the wave condition. 5 types of buoy made up of short cylinder laid vertically (CL-V), short cylinder laid horizontally (CL-H), capsule (CS), sphere (SP) and long cylinder (CL-L) were used for experiments. A mooring line and a weight were connected with each buoy. A tensile gauge was installed between a mooring line and a weight. All buoy's mooring tension was measured at the same time for the wave test with periods of 1.5~3.0 sec and wave heights of 0.1~0.3 m, and the current test with flow speeds of 0.2~1.0 m/sec. As a result, the order of tension value in the wave test was CL-H > CL-V > SP > CS > CL-L. In the current test CL-V and CL-H were recorded in the largest tension value, whereas SP has the smallest tension value. So it seems that SP buoy is the most effective in the location affected by fast current. CS is predicted to be suitable for a location that influence of wave is important more than that of current if practical use in the field is considered. And it was found that the difference of mooring tension among buoys in wave is related to the product of the cross sectional area and the drag coefficient for the buoy's bottom side in high wave height. The factor for the current condition was not found. But it was supposed to be related to complex factors like a dimension and a shape by buoy's posture to flow.

물 순환 및 에어레이션용 에어리프트 펌프의 성능 (Performance of Airlift Pumps for Water Circulation and Aeration)

  • 오세경
    • 한국수산과학회지
    • /
    • 제25권6호
    • /
    • pp.529-537
    • /
    • 1992
  • 본 실험은 에어리프트 펌프의 펌핑 성능과 에어레이션 능력을 조사하기 위해 수행했다. 펌프로는 2, 3, 4, 6인치 내경의 PVC 파이프를 사용했으며 펌프의 길이는 34.5인치였다. 공기 공급장치로는 정격 1 마력의 불로워를 사용하였다. 공기 유량 계측은 유량 게이지(풍속계)를 사용하였으며, 공기 압력은 물이 펌핑될 때 수위 변화로 측정했다. 펌프에 의한 에어레이션 성능 시험은 표준 에어례이션 테스트 방법으로 수행했다. 그 때 펌프출구의 중심선의 위치는 물 표면으로부터 3인치 위가 되도록 설정하였다. 수중의 산소농도는 에어레이션율을 산출하기 위하여 측정되었다. 탱크 속에서 수위 설정은 에어리프트 점프의 위치를 상하로 변경시켜 조절했다. 그 결과 수면에서 펌프의 위치가 높은 상태에서 물의 토출양은 공기의 공급량이 증가함에 따라 감소했다. 물 토출량의 감소율은 4인치와 6인치 펌프에서 높았으며, 직경이 작은 펌프에서 감소율은 그 정도가 미미했다. 시간의 변화에 따라 측정한 각 펌프의 에어레이션 성능은 2인치 펌프를 제외하고 3, 4, 6인치 펌프에서 비슷한 결과를 보았다. 6인치 펌프는 점핑 수두를 최소로 했을 때 가장 우수한 물 순환 효과를 얻을 수 있었다.

  • PDF

사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안 (Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path)

  • 김정수;송주일;임창수;윤세의
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.

메쉬접지전극과 차폐패넬을 이용한 접지저항 및 접지전극간의 영향에 관한 연구 (Study on the Between the Grounding Resistance and Grounding Electrode using Mesh Grounding Electrodes and a Shielding Panel)

  • 이충식;조문택;나승권
    • 한국항행학회논문지
    • /
    • 제19권3호
    • /
    • pp.230-236
    • /
    • 2015
  • 본 논문에서는 접지전극이 상호 간섭의 문제가 발생했을 때 파급효과가 큰 차폐시스템의 패넬과 접지전극으로 널리 사용되고 있는 봉상전극, 메쉬전극, 판상전극을 2차원에 점 전류원의 집합체로 가정하여 이에 대한 전극표면전위를 이용하였다. 실험에 사용한 수조모델의 유한성과 축척에 의해 제작된 모델전극의 축척한계를 수조모델의 크기에 대해 실험오차에 따른 중단오차를 최대한 줄이는 수법으로 실험모델전극을 선정하였다. 복수의 접지도체가 동일 접지저항구역 내에 존재할 경우 도체의 형상 및 매설 조건에 따른 간섭효과의 척도로 사용되는 전위간섭계수의 도출 방법을 제시하였다. 또한 실험에 사용한 접지전극의 수치시뮬레이션을 통해 이론의 타당성을 검증하고, 검증된 이론과 모의실험을 통해 본 연구를 구체화 하였다.

유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구 (Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation)

  • 차재환;신경숙;박승국;신정훈;김병군
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.