• Title/Summary/Keyword: Water Supply System

Search Result 1,476, Processing Time 0.03 seconds

The deployment Advanced Technology of Water supply line breakage detection system in Songsan Green City (송산그린시티(동측)내 선진 상수관로파손감시시스템 구축기술)

  • Kwag, Jun keun;Park, Ji Young;Yoon, Sang Jo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.291-295
    • /
    • 2022
  • This paper deal with the advanced thchnology of water supply line breakege detection system in singsan green city. the technology apply for construction eco oriented high-tech city to merge residant, industial, tour reasure parts for songsan green city furture direction achivement and response for a life style change of people in the city. Breakege detection system consist of smart prevention seat, pipeline breakege detection sensor, analysis software, server. etc.. Central control unit sent the data to hwa sung city water supply office by WCDMA in SKY. the data are states about water supply pipeline, Location.etc. This system maintain the long term life cycle of water supply plpeline by the prevention the leakege event through ackonwledge information of evnet occurrence locaion. and used to realtime sense method about demage information of the pipeline and prevent to brekege facilities during excavation work.

  • PDF

EVALUATION OF THE WATER RESOURCES ASPECT OF THE OPERATING RESULTS OF THE DAECHEONG MULTIPURPOSE DAM

  • Noh, Jaek-young
    • Water Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.17-36
    • /
    • 2004
  • This paper evaluated the water resources aspect of the operating results of the Daecheong Multipurpose Dam for the last 21 years. The elements that were evaluated included the amount of water supply from the dam. volume of outflow from the regulating dam, changes in the runoff volume at the dam site and downstream, and variations in the water supply capacity of the Daecheong Multipurpose Dam and the Geum River Barrage Dam situated in the estuary. The rainfall-runoff model was used to evaluate the changes in the runoff volume, and the water balance analysis system was used to evaluate the variations in the dams'water supply capacities. The volume of domestic and industrial water supply from the Daecheong Multipurpose Dam increased to 6.1 times for the last 21 years from 61${\times}$$10^6$$m^3$ in 1981 to 375${\times}$$10^6$$m^3$in 2001. The rate of outflow to inflow of the Daecheong Dam was analyzed 1.30 times in dry season, 1.12 times in semi-dry season, and 0.90 times in rainy season. The volume of inflow to the Geum River Barrage Dam down- stream after the dam's construction increased to 1.25 times in dry season and 1.02 times in semi-dry season and decreased to 0.94 times in rainy season. The water supply capacity of the estuary barrage dam almost did not change in cases with or without the Daecheong Multipurpose Dam, but storages were largely affected by the outflows of the Daecheong Multipurpose Dam.

  • PDF

Development of the Novel Dry and Wet Deposition Collector (새로운 건성 및 습성 침착 채취기의 개발)

  • 이병규;이채복
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

Demonstration study on Desalination System using Solar energy (태양에너지 해수담수화시스템 실증)

  • Kim, Jeong-Bae;Joo, Hong-Jin;Yoon, Eung-Sang;Joo, Moon-Chang;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2007
  • In this research, to develop the practical application system of fresh water generation system with plate-type fresh water generator using low pressure evaporation method is the main object, and to do that, this study used the evacuated solar collector with operating range of about $50-85^{\circ}C$ as thermal energy source and solar photovoltaic as electric energy source. To achieve that object, this study set up the demo-plant, then estimated and analyzed the usefulness, the safety, and the reliability through pre-tests during short time ahead of the long-time operation. This study showed that the pumps, which are including sea water supply, ejector, hot water supply, and fresh water pumps, were operated one after another. And, the fresh water yield was closely related with the solar irradiance and lower supply temperature of hot water was revealed more reasonable for the solar energy desalination system. That is due to the insufficient area than the solar collector area being required that was estimated through the performance tests of the fresh water generator.

A Study on Vegetated Embankment Slope Reinforcement Using A Synthetic Resine Based Net-hose System (합성수지 소재 네트호스 시스템을 이용한 성토사면 녹화 보강에 대한 연구)

  • Baek, Yong-Gi;Lee, Min-Kyu;Ahn, Jaehun;Oh, Jeongho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.8-13
    • /
    • 2015
  • This study investigates the application of a synthetic resine based net-hose system to sustain vegetated embankment slope reinforcement. The net-hose system is designated to improve water supply to the vegetation that can suffer the lack of water in case of extreme drying condition or rock slope where water supply is relatively insufficient to ensure the growth of vegetation. A series of laboratory tests were conducted to check the structural adequacy and effectiveness of net-hose system. The results indicated that the model slope equipped with net-hose system seemed to provide better water supply resulting in more vegetated areas and higher matric suction due to active water uptake capacity, which might be contributed to greater shear strength of slope surface. A limited numerical analysis was conducted to verify the effect of water uptake on vegetated root system that generally yields better slope stability.

A mini-review on discharge characteristics and management of microplastics in sewage treatment plants (국내·외 연구사례를 통해 본 하수처리시설 미세플라스틱 배출특성 및 관리방안 고찰)

  • Jeong, Dong-Hwan;Ju, Byoungkyu;Lee, Wonseok;Chung, Hyenmi;Park, Junwon;Kim, Changsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.337-348
    • /
    • 2018
  • As the issue of microplastics (MPs) detection in tap water was raised in other countries in 2017, monitoring of MPs in drinking and source water, and sewage treatment plant (STP) effluents was initiated. This study intends to look into other studies on MPs in STPs at home and abroad, and review the characteristics of MPs and their removal efficiencies in the STPs, the risk and effect of MPs on watersheds, and management practices in order to help better understand MPs in STPs. To manage MPs effectively in STPs, it is necessary to investigate the detection of MPs discharged from STPs, do research on human health risk and control measures, and build a monitoring system including standardized analytical methods.

Assessing Sustained Drought Impacts on the Han River Basin Water Supply System Using Stochastic Streamflows (추계학적 모의유량을 이용한 한강수계 용수공급시스템의 장기지속가뭄 영향 평가)

  • Cha, Hyeung-Sun;Lee, Gwang-Man;Jung, Kwan-Sue
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.5
    • /
    • pp.481-493
    • /
    • 2012
  • The Uncertainty of drought events can be regarded as supernatural phenomena so that the uncertainty of water supply system will be also uncontrollable. Decision making for water supply system operation must be dealt with in consideration of hydrologic uncertainty conditions. When ultimate small quantity of precipitation or streamflow lasts, water supply system might be impacted as well as stream pollution, aqua- ecosystem degradation, reservoir dry-up and river aesthetic waste etc. In case of being incapable of supplying water owing to continuation of severe drought, it can make the damage very serious beyond our prediction. This study analyzes comprehensively sustained drought impacts on the Han River Basin Water Supply System. Drought scenarios consisted of several sustained times and return periods for 5 sub-watersheds are generated using a stochastic hydrologic time series model. The developed drought scenarios are applied to assess water supply performance at the Paldang Dam. The results show that multi-year drought events reflecting spatial hydrologic diversity need to be examined in order to recognize variation of the unexpected drought impacts.

THE ANALYTIC ANALYSIS OF THE CORE INJECTION COOLING FLOW RATE FOR EMERGENCY WATER SUPPLY SYSTEM IN HANARO (하나로 비상 보충수 공급계통의 노심 주입 냉각유량 해석)

  • Park Yong-Chul;Kim Bong-Soo;Kim Kyung-Ryun;Wu Jong-Sub
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.39-44
    • /
    • 2005
  • In HANARO, a multi-purpose research reactor of 30 MWth, the emergency water supply system consists essentially of an emergency water storage tank located in the level of about thirteen meter (13 m) above the reactor core, a three inch ('3\%') diameter water injection pipe line including injection valves from the tank to the reactor cooling inlet pipe and a test loop to do periodic system performance test. When the water level of the reactor pool comes down to the extremely low due to a loss of reactor pool water accident the emergency water stored in the tank should be fed to the core by the gravity force and at that time the design flow rate is eleven point four kilogram per second (11.4 kg/s). But it is impossible periodically to measure the injection flow rate under the emergency condition because the normal water level should be maintained during the reactor operation. This paper describes a flow network analysis to simulate the flow rate under the emergency condition. As results, it was confirmed through the analysis results that the calculated flow rate agrees with the design requirement under the emergency condition.

  • PDF

Decision Making Support System for Water Supply Facilities Planning using Geographic Information System (GIS를 이용한 상수도(上水道) 계획(計劃) 의사결정(意思決定) 지원(支援)시스템 연구(硏究))

  • Ha, Sung-Ryung;Kim, Ju-Hwan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.3 no.2 s.6
    • /
    • pp.101-113
    • /
    • 1995
  • In pipeline planning, the systematic and reasonal management of topographical and spatial data are needed in order to omprove the availibilities for data analysis and the effective combinations of spatial informations. According to that fact, DBMS (Database Management System) and DSS(Decision making Support System) have to be developed for the planning of water supply system Also, the economic selection for harmonious delivery of water to target area, since the alternatives of pre-designed pipeline are influenced by hydraulic stability and geographic characteristics. In this study, GIS technique for water supply planning and management which stores graphic features and attributes as digital data sets is considered and engineering application programs are integrated for effective planning of water supply system. Decision making support system based on analyzing technical, Social and economical aspects is developed for the extension of water supply facilities and pipeline configurations. Especially, Hydraulic, land-use and economic influences are considered as important factors for the purpose of developing the system. Hydraulic analysis program(SAPID) for pipeline flow which is already developed in Water Resources Research Institute and economic analysis program(ECOVEL) are integrated with GIS for resonable decision making. Every possible aspects in pipeline planning for water supply is reviewed and the applicabilities of developed system into the field are evaluated.

  • PDF

Real-time Water Supply Facilities Monitoring System based on the USN (USN 기반의 실시간 수도설비 모니터링 시스템)

  • Kim, Yong-Tae;Yoo, Neung-Hwan;Park, Gil-Cheol;Kim, Seok-Soo;Kim, Tai-Hoon;Lee, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1207-1213
    • /
    • 2007
  • This paper has researched water supply facilities management using real-time water utility monitoring system based on USN(Ubiquitous Sensor Network) which is consisted of wireless sensors transferring waterworks facilities md treatment information about a valve-room and flowmeter-room of water supply installation. In the manholes, it was installed with flowmeter, pressure sensors, vibration sensors, Co-sensors, and hydro-thermograph sensors. These measurement values which are received by PDA are used for facilities operation on the spot safely and conveniently. It has also provided safe installation management via CDMA(Code Division Multiple Access) network which transfers data to remote servers to monitoring at a distance place. With safety management system of water supply facilities on USN technology convenience and safety is increased in real situation, and it is expected that we can supply clean water to people as much safer and more effective water supply installation management.