• Title/Summary/Keyword: Water Spray

Search Result 962, Processing Time 0.024 seconds

Analysis of spray cone angle of air assisted flash atomization (공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구)

  • Yu, Tae-U;Kim, Sae-Won;Bang, Byong-Ryeol
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF

A Study of Computational Fluid Dynamics Analysis for the Water Spray Distance of Long Jet Monitor (Long Jet Monitor의 소화수 분사 거리에 대한 유동 해석적 연구)

  • Jae-Sang Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.907-913
    • /
    • 2023
  • Currently, the sprinkler method is widely used as an initial suppression method in existing firefighting systems. However, this method can cause significant damage to both equipment and facilities in the hydration area. To minimize this damage, fire extinguishing monitors are being developed that can spray fire extinguishing water directly at the point of fire. These monitors are installed on the top floor of the ship, such as the Living Quarter and Ventilation System. While conventional fire extinguishing monitors focus on lightweight research with a short spray port and require a spray distance of about 40 to 45m, recent developments necessitate a longer spray port, similar to a water cannon, requiring a spray distance of about 70 to 75m. This study aims to predict the injection distance of both the existing ship-installed fire extinguisher and the long spray port fire extinguisher through hydrodynamic computer analysis, and to determine whether the injection distance has increased.

Effect of Water on Continuos Spray and Flame in Emulsified Fuel made by Ultrasonic Energy (초음파 에너지로 제조된 유화연료의 수액이 분무 및 화염에 미치는 영향)

  • Lee, Seung-Jin;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 2005
  • To investigate spray and combustion of emulsified fuel of W/O type, we mixed water with light oil by using ultrasonic energy adding system. We measured the SMD of sprayed droplet to find atomization characteristics of emulsified fuel with using the Malvern 2600D system. Major parameters are the weight ratio of water($0{\sim}30%$ by 10%) in emulsified fuel injection pressure(lobar), and the measurement distance($10{\sim}100mm$ by 10mm). Combustion visualizing system is made up commonly used boiler system and digital camera 1/500s to investigate combustion phenomena. As a result, the more water contents increased, the more SMD increased. The water particle of emulsified fuel made short flame in continuos spray combustion phenomena because of micro explosion.

  • PDF

Analysis for fire suppression efficiency of intermittent water spray pattern with FDS (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.200-203
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively low and the infiltration of water mist to the fire source is not effective. In addition to lower penetration force, the evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist system is expected to improve the penetration force of water mist as well as the dilution coverage capability with the stratified spray characteristics. At this paper we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis shall be supportive to the development of the prototype of water mist nozzle.

  • PDF

Prediction of Heat Transfer Rates to Spray Water Droplets in a High Pressure Mixture Composed of Saturated Steam and Noncondensable Hydrogen Gas (고압의 포화수증기-비응축성 수소기체 혼합기 속에서 분무수적으로의 열전달을 예측)

  • Lee, S.K.;Jo, J.C.;Cho, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.337-349
    • /
    • 1991
  • Heat and mass transfer rates to spray water droplets for spray transients in a high pressure vessel have been predicted by two different droplet models: the complete mixing model and the non-mixing model. In this process, the ambient fluid surrounding the droplets is a real-gas mixture composed of saturated steam and noncondensable hydrogen gas at high pressure. The physical properties of the mixture are estimated by applying the concept of compressibility factor and using appropriate correlations. A computer program, DROPHMT, to calculate the heat and mass transfer rates for two different droplet models has been developed. As an illustrative application of the computer program to engineering practices, heat and mass transfer rates to spray water droplets for spray transients in a Pressurized Water Reactor (PWR) pressurizer have been calculated, and the typical results have been provided.

  • PDF

A Study on the Interaction Effect Between Spray Fan Formed by Gas/Liquid Swirl Injector (기체/액체를 사용하는 Swirl 인젝터의 간섭효과에 관한 연구)

  • Joung, Rae-Hyuck;Kim, Yoo;Cha, Young-Ran;Park, Joung-Bae;Park, Uoo-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • Experimental study was carried out to investigate the interaction effect between spray fan formed by gas/liquid swirl injector. Test variables were supply pressure and injector distance. Water and air were the simulant for the experiment. For water supply only; Collected water mass was concentrated at the lower part of the two spray fan, but this effect was reduced with increasing supply pressure. Both air and water supply1; Collected water mass was again concentrated at the lower part of the impingement point, but this effect was reduced when air/water supply pressure ratio was increased.

  • PDF

The Effect of Property of Emulsified Fuel and Injection Pressure on the Spray Characteristics for Super-Critical-Pressure Burner (초임계압 보일러용 유화연료의 물성치와 분사압력이 분무특성에 미치는 효과)

  • Lee, I.S.;Jung, J.W.;Cha, K.J.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.38-44
    • /
    • 2002
  • The purpose of this study is to investigate the effect of the volume fraction of water and injection pressure on the spray characteristics of water/oil emulsified fuel injected from the pressure swirl atomizer. The mixture of light oil and water by using impeller mixer was performed. The spray characteristics such as SMD and velocity were measured using PDPA. The injection pressures were 7.5, 100, 200 and $300kgt/cm^2$ and volume fractions of water in emulsified fuel were 0, 10, 20 and 30%, respectively. The measurement sections were at 30, 60 and 90mm from injection nozzle tip. SMD and velocity of emulsified fuel were larger gradually by increasing the volume fraction of water in emulsified fuel. The spray angle was decreased and axial velocity was increased with increase in water content. It was found that the relative SMD ratio was increased more greatly than the relative axial velocity ratio in super critical pressure. The relative SMD ratio was increased and the relative axial velocity ratio was decreased with increase injection pressure at spray downstream.

  • PDF

A Study on the Performance of Water Mist Spray Fire Protection System (미세물분무 소화성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

A Study on the Injection Characteristics of Diesel-water Emulsion Fuels according to Compositions (디젤-워터 에멀젼 연료의 조성에 따른 분무 특성에 관한 연구)

  • Woo, Seungchul;Kim, Hyungik;Park, Jangsoo;Lee, Kihyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.263-270
    • /
    • 2015
  • Using Diesel-Water Emulsion fuel in commercial diesel engine can reduce NOx and soot when it is injected through the injector. Because water in Diesel-Water Emulsion fuel is vaporized ahead of diesel particle and it cause decrease of combustion temperature. Furthermore, research about the possibility of applicating Diesel-Water Emulsion fuels to commercial diesel engine is demanded in order to prove that Diesel-Water Emulsion fuel is able to apply commercial diesel engine without any replacement of equipments. This research analyzed applicable possibility of Diesel-Water Emulsion fuels to commercial diesel engine's fuel injection system refering injection and spray characteristics. In this research, there are 3 experiments, that is injection quantity, spray visualization, and injection rate. Diesel-Water Emulsion fuel has less injection quantities compared to diesel fuel, and spray penetration length is more longer than diesel. Furthermore, emulsion fuels have less dispersed than diesel fuel. In conclusion, comparing with diesel fuel with only spray characteristics, Diesel-Water Emulsion fuel has bad effects about dispersion and vaporization.

A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer- (물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향-)

  • Lee, Pil-Jong;Jin, Sung-Tae;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.