• 제목/요약/키워드: Water Spray

검색결과 966건 처리시간 0.03초

오리멀전의 플래쉬 분무 및 연소특성에 관한 연구 (A Study on Flash Spray and Combustion Characteristics of Orimulsion)

  • 신명철;류태우;김세원;방병열
    • 한국연소학회지
    • /
    • 제10권4호
    • /
    • pp.18-23
    • /
    • 2005
  • This study focused on the use of orimulsion in industrial combustion systems. Orimulsion is a bitumen-in-water emulsified fuel, which contains a thirty percent water. Orimulsion has relatively high levels of sulfur and nitrogen compared to many fuel oils, and has been the subject of much debate regarding the environmental impacts of its use. The goal of this research is to analyze the effect of flash spray combustion characteristics of orimulsion on NOx and particulate material reduction. For the flash spray of orimulsion, it is heated to $150^{\circ}C$. The effects of fuel heating temperatures on NOx and particulate material emissions were investigated experimentally. As the fuel temperature was increased, NOx and particulate material concentrations in flue gas were decreased.

  • PDF

감마선 조사에 의해 제조된 나노-실리카은 유무기복합 입자를 포함한 항진균성 스프레이 제제의 생활환경 저해균에 대한 실용성 검토 (A Test of Antifungal Spray Formulation Containing Nanosized Silica-Silver Particles Prepared by Using Gamma Irradiation for Practical Use to Control Indoor Fungi)

  • 김성호;박해진;김화정;박해준
    • 방사선산업학회지
    • /
    • 제2권3호
    • /
    • pp.149-154
    • /
    • 2008
  • The present study described an antimicrobial spray composition comprising nanosized silica-silver particles, in which nano-silver is bound to silica molecules and a water-soluble polymer, the nanosized silica-silver particles prepared by irradiating a solution comprising a silver salt, silicate and the water-soluble polymer with radiation rays. According to a surfactant addition, the compositions were not turbid and were colorless. Also samples (cotton fabrics and wallpaper) were treated with the compositions also did not cause any stains even after drying under sunshine and at $80^{\circ}C$. Our results suggested that the spray formulation product was of practical use to control indoor fungi.

이중 선회 분무간의 거리와 연료온도 변화에 따른 분무특성에 관한 실험적 연구 (The Experimental Study on the Effects of Temperature and Distance between Injectors on the Spray Characteristics of Duplex Swirl Injector)

  • 최경식;박병성;김호영;민성기
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.11-15
    • /
    • 2002
  • Experimental studies on effects of the interaction of duplex swirl injector and the liquid temperature on the spray characteristics were conducted. Water and fuel were used as a test fluid for the experiments. The drop size distributions of the liquid spray were measured with Malvern particle sizer. The liquid temperature and distance of injectors were adopted as the operating parameter. The results show that SMD decrease as the increases of fuel temperature and pressure. The spray angle increase as fluid temperature increases. For fuel spray, SMD of impacting surface increase as the distance of injectors is lengthened.

  • PDF

마이크로 휜 표면의 분무냉각 열전달에 관한 실험적 연구 (Experimental Study on Spray Cooling Heat Transfer of Micro-Fins Surfaces)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제14권4호
    • /
    • pp.178-183
    • /
    • 2009
  • Spray cooling heat transfer was experimentally investigated for water sprays impacting on mico-fins structured surfaces in the single phase and nucleate boiling regions. The heat transfer surfaces consist of cubic fins and triangular grooved fins. The spray produced using full cone spray nozzles, and experiments were made under the test condition of $Q=4.92{\times}10^{-6}{\sim}15.83{\times}10^{-6}\;m^3/s$, $T_f=35{\sim}55^{\circ}C$. From the experimental results, it was found that cubic fins surface had the largest heat flux enhancement relative to the smooth surface.

  • PDF

노즐이 내부형상이 이중분무의 유속과 입경에 미치는 영향 (Effect of Internal Geometry of Nozzle on the Velocity and Droplet Size of Twin Spray)

  • 김영진;정지원;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1522-1527
    • /
    • 2004
  • The purpose of this study is to investigate the effect of swirler angle and swirl chamber aspect ration of nozzle on the characteristics of single and twin spray. The performances of nozzle has been investigated by measurements of spray angle, droplet size, velocity and Weber number at a water pressure 0.4MHz. Visualization of spray was conducted to obtain the spray angle and breakup process. The spray characteristics such as droplet size and velocity were measured by Phase Doppler Anemometry(PDA). It was found that the smaller swirler angle, the larger axial velocity became. It was also shown that the larger aspect ratio, the smaller droplet diameter became.

  • PDF

콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구 (An Experimental Study on the Permeability Evaluation of Metal Spray System by Concrete Surface Treatment)

  • 박진호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.34-35
    • /
    • 2015
  • Recently, introduction of Advanced water treatment facilities has been increasing due to serious domestic water pollution. Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구 (Thermal Performance Characteristics of Closed-Wet Cooling Tower)

  • ;김은필;문춘근;윤정인
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

Practical Experiences with Corrosion Protection of Water Intake Gates in Mekong River

  • Phong, Truong Hong;Tru, Nguyen Nhi;Han, Le Quang
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.328-331
    • /
    • 2008
  • Corrosion behaviour of water intake gate steel structures with different protective measures was investigated. Five material alternatives were taken for investigation, including: imported and recycled stainless steel, carbon steel with hot zinc spraying, painting and composite coatings. Results of corrosion rate for carbon steel, SUS 304, hot zinc spray coats in three water systems of Mekong river basin (saline, blackish and fresh) were also presented. Corrosion rate of carbon steel decreased with decreasing salinity in the investigated water environments. Meanwhile, these values for zinc coated steel, behaved by another way. Environmental data for these systems were filed and discussed in relation with corrosion characteristics. Method of Life Cycle Assessment (LCA) was applied in materials selection for water intake gate construction. From point of Life Cycle Cost (LCA) the following ranking was obtained: Zinc sprayed steel < Recycled stainless steel < Composite coated steel < Painting steel < SUS 304 From investigated results, hot zinc spray coating has been applied as protective measure for steel structures of water intake systems in Mekong river basin.

스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험 (Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures)

  • 심규호;정민성;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.