• Title/Summary/Keyword: Water Spray

Search Result 966, Processing Time 0.031 seconds

An Experimental Study on the Application for High Pressure Spray by Heat Cycle Type Equipment to Improve Work Safety and Workability of Asphalt Water Proofing method. (아스팔트 방수공법의 시공성 및 작업안전성 개선을 위한 열순환 방식의 고압 분사장치 적용에 관한 실험적 연구)

  • Chung, Chang-Pyo;Song, Je-Young;Lee, Sun-Kyu;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.33-39
    • /
    • 2009
  • Asphalt waterproofing method has a long history over 80years since introduce to domestic market. This method has a good point as high water proofing not permeable to water by material performance of bitumen, In spite of high waterproofing, the application has become decreased. This asphalt method has some problem such as work safety, low workability by complicated work process, environmental problem in job site, it should be solve by complementary measures. 'Therefore, in this paper, suggest the principle of high pressure spray by heat cycle type equipment by analysis of exist problem and materials investigation. And. study and examine the spray type degeneration rubberized asphalt membrane materials to adopt job site. Moreover, suggest the evidence by inspection about waterproofing performance by Korean Industrial Standard through the performance test of the spray type degeneration rubberized asphalt membrane materials.

  • PDF

Basic Study of Spray-Behavior Characteristics of Emulsified Fuel (에멀젼연료의 분무거동특성에 관한 기초연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.763-771
    • /
    • 2014
  • As a preliminary study on the spray behavior characteristics of emulsified fuel, the fuel properties (viscosity, surface tension, and density) and evaporation characteristics of a fuel droplet were investigated. The emulsified fuel was made by mixing diesel and $H_2O_2$. In addition, the macroscopic spray behavior characteristics such as the spray penetrations and spray angles of the emulsified and diesel fuels were compared. The stirring condition of the emulsified fuel was a 9:1 mixture of the diesel fuel and the surfactant span 80. The mixing ratios for the hydrogen peroxide were set at EF2, EF12, EF22, EF32, EF42, EF52, EF62, EF72, EF82, and EF92. The injection pressures were set at 400, 600, 800, and 1000 bar. We found that as the mixing ratio of the hydrogen peroxide was increased from EF2 to EF52, the viscosity of the emulsified fuel increased. However, afterward, the viscosity of the emulsified fuel gradually decreased and approached the viscosity value of the diesel fuel. Therefore, generally oil-in-water emulsions were used for the hydrogen peroxide mixing ratios up to 52 (EF52), and water-in-oil emulsions were used for the hydrogen peroxide mixing ratios above 52. Finally, the spray behavior characteristics (spray penetration and spray angle) of the emulsified fuel were found to be almost independent of the mixing ratio.

Spray Characteristics of In-Rack Sprinkler Heads (인랙스프링클러 헤드의 살수 특성)

  • Kim, Jong Hoon;Joung, Woo In;Myoung, Sang Youb;Jeong, Keesin;Kim, Woon Hyung
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2017
  • The aim of this study is to find out the water spray features of in-rack sprinklers for rack storage. This study conducted cold water flow test, measurement of spray angle and densities by angles for sprinkler head manufactured by a Korean company and a U.S. company. Korean sprinkler head had a wide angle of water spary. The water spray angle of a U.S. sprinkler head was narrow compared to the Korean sprinkler. In comparison of the Korean head with U.S. head of the same K80, the Korean head can send water to parts that are difficult to directly spray, but the spraying density by angle was low. U.S. head can send more water than Korean head at a narrow angle. In conclusion, for flammable materials placed in two or more rows in a rack storage, a zigzag arrangement with face sprinklers will be effective.

An Experimental Study of Extinguishiment of Purely Buoyant Diffusion Flame Using Water Drops (수적을 이용한 순수확산화염의 소화에 관한 실험적 연구)

  • Jang, Yong-Jae;Kim, Myeong-Bae;Kim, Jin-Guk
    • 연구논문집
    • /
    • s.24
    • /
    • pp.41-48
    • /
    • 1994
  • This experimental study deals with the extinguishiment characteristics of an oil pool flame using the water spray. The water through the six different atomizers is ejected over the freely burning pool flame in the quiescent surrounding air. Injection direction is vertical to the surface of oil in a small tank with a diameter of 100mm and a height of 10mm. In order to estimate quantitatively the extinction, the burning rate as well as the effective water flux are measured. The effective water flux is the amount of the water which reach the pool from the nozzle. The burning rate with the water spray increases until the injection pressure increases to reach some value, which gives the maximum burning rate, while the effective water flux without the flame decreases or does not change according to increasing of the injection pressure. This maximum burning rate is greater than 2.5 times of burning rate of the fire without the water spray. As a matter of the extinguishiment, it is found that the water drops of which size is too small can not extinguish the fire because too small drops does not reach the fuel surface.

  • PDF

Durability of Carbon/Epoxy Composites for Train Carbody under Salt Water Environment (염수환경에 노출된 철도차량용 탄소섬유/에폭시 복합재의 내구성 평가)

  • Hwang, Young-Eun;Yoon, Sung-Ho;Kim, Jung-Suk;Han, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.852-858
    • /
    • 2007
  • The durability of carbon/epoxy composites under salt water environment was investigated through salt water spray tester. Salt water environment was obtained through salt spray and salt immersion. 5% NaCl solution was used for salt water as natural salt water. Mechanical test was performed to obtain tensile properties, flexural properties, and shear properties of carbon/epoxy composite over 12 months under salt water environment. Dynamic mechanical analyzer was used to investigate thermal analysis properties such storage modulus, loss modulus, and tan ${\delta}$. Also FT/IR test was conducted to investigate a change in chemical structure. According to the results, mechanical properties were found to be slowly degraded as a function of exposure times. Regarding to thermal analysis properties, storage modulus was insensitive to exposure times, but loss modulus was shown to be slightly decreased. Although the shape and location of peak in FT/IR were not much changed, the intensity of peak in FT/IR was affected on exposure times. We also found that salt water immersion was more severe to the durability of carbon/epoxy composite rather than salt water spray.

  • PDF

Study on the Characteristics of Long Wave Infrared Signal by Water Injection around the Exhaust Plume of the Micro-jet Engine (마이크로 제트엔진 배기플룸 주위 물 분사에 따른 장파장 적외선 신호특성 연구)

  • Yu, Gunwon;Choi, Seongman
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.2
    • /
    • pp.28-39
    • /
    • 2022
  • An experimental study was carried out to understand the characteristics of the long wave infrared signal emitted from the exhaust plume when water is sprayed around it. The micro-jet engine was used to generate the exhaust plume, and eight water spray nozzles were installed around the exhaust nozzle. Two water injection angles were applied, one is sparying parallel to the exhaust plume, and the other is spraying water into the exhaust plume. The measurement results are as follows. When spraying water parallel to the exhaust plume, the long wave infrared signal is decreased with water spray flow rate. When spraying water the exhaust plume, the long wave infrared signal shows a larger value than plume only.

Effects of opening distance on liquid-gas spray of pintle injector under atmospheric condition (핀틀 인젝터의 개도가 액체-기체 상압 분무에 미치는 영향)

  • Yu, Kijeong;Son, Min;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.585-592
    • /
    • 2015
  • Effects of opening distance on liquid-gas spray of pintle injector were experimentally investigated under atmospheric condition by using water and air as simulants of propellants. Discharge coefficients($C_d$) and mass flow rates were calculated with various injection conditions; 0.1 bar - 1.0 bar for water pressures and 0.2 mm - 1.0 mm for the pintle opening distances. Spray angles were measured from the spray images that were obtained by a shadowgraphy method. When opening distance is 0.2 mm, liquid sheet is not formed properly and it show non-uniform spray. than it can result in combustion instability. it has a weak correlation between the momentum flux ratio and the spray angle, while it has a strong correlation between the momentum ratio and spray angle. Finally the spray angles reduced exponentially when the momentum ratio increased and the spray angles converged to about 40 degrees.

Development of the low Emission type Fuel Feeding System for Diesel Automobile I (Characteristics and Spray of Emulsified Fuel) (디젤자동차의 저공해형 연료공급장치 개발 I (유화연료의 특성 및 분무거동))

  • Cho, S.C.;Yoon, M.K.;Ryu, J.I.
    • Journal of ILASS-Korea
    • /
    • v.2 no.3
    • /
    • pp.8-16
    • /
    • 1997
  • Ta investigate characteristics and spray of emulsified fuet we are mixed water with diesel oil using ultrasonic energy fuel feeding system. Separation ratio of emulsified fuel was shown good condition that of water content is small and longer ultrasonic energy adding time. Viscosity of emulsified fuel increased 79% with addition to water content and surface tension increased 1.6% in comparision to pure diesel oil. The SMD of emulsified fuel adding ultrasonic energy decreased with 3% in comparision to pure diesel oil. With increasing 5, 10% water content the SMD decreased 15.6, 20.1% in comparision to pure diesel oil. The mind-explosion was investigated with 4step.

  • PDF

Collection characteristics of wet-type cyclone with wall cavity for air pollutants removal of marine diesel engines (선박 대기오염 저감을 위한 벽면 캐비티 적용 습식 사이클론의 집진특성)

  • Yoa, Seok-Jun;Kwon, Jun-Hyeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.2
    • /
    • pp.185-192
    • /
    • 2014
  • The main object of this study was to investigate the collection characteristics of wet-type cyclone with wall cavity. The experiment was executed to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, water spray type, inlet velocity etc. In results, for the present system of wet-type, the pressure drop represented 35 mm $H_2O$, while in dry-type 33 mm $H_2O$ showing lower 6% at $v_{in}=21m/s$. In case of $v_{in}=21m/s$ and water spray 200 mL/min, the collection efficiency of the present system became significantly higher as 96.8% comparing to that of the conventional wet-type scrubber. Additionally, for 200 mL/min, $SO_2$ removal efficiencies decreased with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}=6,9,12m/s$, respectively.

A Study on the Performance of Heat Exchanger for Closed Cooling Tower (밀폐식 냉각탑용 열교환기의 성능에 관한 연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ahn, Young-Hwan;Park, Hyoung-Joon;Ryu, Hae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF