• Title/Summary/Keyword: Water Screen System

Search Result 89, Processing Time 0.028 seconds

Sea water Treatment using an Automatic Backwashing Filter (자동역세척 여과장치를 이용한 해수처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.241-245
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effectof after processing processof the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed of filtration filter could be expose by 35mmHg more than 60 rpm and filter consecutively filtration pressure is 40.5mmHg in 20 rpm and 40 rpm are 36.6mmHg. Filtration system removal aquatic organism over $70{\mu}min$ ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

Thermal analysis and optimization of the new ICRH antenna Faraday Screen in EAST

  • Q.C. Liang ;L.N. Liu ;W. Zhang ;X.J. Zhang ;S. Yuan ;Y.Z. Mao ;C.M. Qin;Y.S. Wang ;H. Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2621-2627
    • /
    • 2023
  • In Experimental Advanced Superconducting Tokamak (EAST) experiments, to achieve long pulse and high-power ICRH system operation, a new kind of ICRH antenna has been designed. One of the most critical factors in limiting the operation of long pulse and high power is the intense heat load in the front face of the ICRH antenna, especially the Faraday Screen (FS). Therefore, the cooling channels of FS need to be designed. According to thermal-hydraulic analysis, the FS tubes are divided into several groups to achieve more excellent water cooling capability. The number of series and parallel tubes in one group is chosen as six. This antenna went into service in the spring of 2021, and it is delightful that the temperature distribution of the FS tube is below 400 ℃ in 14.5 s and 1.8 MW ICRH system operation. However, the active water-cooling design was not carried out on the upper and lower plates of FS, which led to severe ablations on that region under long pulse and high power operation, and the temperature is up to 800. Therefore, the upper and lower side plates of the FS were designed with water cooling based on thermal-hydraulic analysis. During the 2022 winter experiments, the temperature of ICRH antenna FS was lower than 400 in the pulse of 200s and the power of 1 MW operation.

Filtering System Design and Structural Analysis for Intake Water of Ship's Ballast Tank (선박 밸러스트 탱크 유입수 필터링 시스템 설계 및 구조해석)

  • Yun, Sang-Kook;Park, Byung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.282-287
    • /
    • 2009
  • As current international guideline and IMO regulation give severe restrictions for ships to manage ballast water to reduce unintentional organism transfers, several ballast water treatment systems recently have been being developed together with filtration. That is because discharging ballast water from ships causes many pollutions by foreign biological invasive species. The primary treatment system being considered in this study was based on fine screen filtration technology applied to ballast water filter in ballast tank in order to reduce the load of ballast water treatment system. New ballast water filtration system was invented and analysed. The structural stress and strain analysis for ballast filtration systems which are current and invented filters were carried out using UGS and Ansys. The results showed that the structure of current filtering module was not designed to meet the requirement of sea water filtration during ballasting operation. The studies also showed that the invented design of filtration system equipped with back washing and automatic scrapper for eliminating cake of bio-species might be a potentially effective technology for ballast water management of ship's ballast tank.

A Study on Development of Korean Urban Fire Simulation (한국형 도시화재 시뮬레이션 개발에 관한 연구)

  • Koo, In-Hyuk;Yoon, Ung-Gi;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.247-248
    • /
    • 2015
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, for development of Korean Urban fire Simulation on Attenuation of Radiant Heat Flux from Water Screen.

  • PDF

Development of Real-Time Musical Visualizing System for the Deaf (청각 장애인을 위한 음악의 실시간 시각화 시스템 개발)

  • Choi, Doo-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.724-726
    • /
    • 1999
  • We have developed a real time musical visualizing system works on PC with sound card and windows 95 or more. The system can extract some features of music signal and animate various screen -i.e wave, spectrum, simulated water jet - according to extracted features. We have used the system at the concert for the deaf and contributed for deaf to understand the music.

  • PDF

Design of EPICS based Control System for RCCS Cooling Water System in PEFP DTL (양성자 가속장치 냉각계통의 제어시스템의 EPICS 구현에 대한 연구)

  • Yoon, J.C.;Kim, K.R.;Kim, H.S.;Kwon, S.J.;Kim, Hui-Seop;Hwang, W.H.;Park, J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1599-1600
    • /
    • 2007
  • The DTL water skid cooling system and Resonant Control Cooling Systems (RCCS) will employ a control system that can be operated by a local, programmable logic controller (PLC), interfaced through a touch screen interface, mobile alarm SMS server system, or it can be operated through the PEFP global control system network. The RCCS is implemented using Experimental Physics and Control System (EPICS) based hardware and software and is integrated with other networked PEFP EPICS systems. This presentation discusses the features of the local control system.

  • PDF

Estimation of Greenhouse Heating performance for Ground Filtration Water Source Heat Pump (강변여과수 열원 히트펌프 온실난방 성능시험)

  • Moon, Jongpil;Lee, Sunghyoun;Kwon, Jinkyung;Kang, YounKoo;Lee, Sujang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.200.2-200.2
    • /
    • 2011
  • This study was carried out in order to estimate the greenhouse performance for Ground filtration water source heat pump which was installed for supplying the heat to the paprika greenhouse in Jinju city. Experimental area of Greenhouse was $3,300m^2$, For keeping the heat from greenhouse, single plastic covering and double thermal screen was installed. With considering all of greenhouse insulation condition and designed heatng temperature, heating capacity for experimental greenhouse was calculated as 320,000kcal/hr. Coefficient of performance(COP) of Ground filtration water source heat pump was gauged and greenhouse heating performance was tested from Febuary 1 to Febuary 28 in 2011. The result showed that COP of heat pump was in the range of 3.7~4.7 and COP of heating system was in the range of 3.0~3.5. The vaule of COP was very high and the temperature inside greenhouse was well corresponded to the setting temperature of greenhouse environment controlling system. lots of Ground filtration water made the the number of well fewer and the expense for installing heating system cheaper than that of geothermal system used custmarily. and this system went beyond the limitation of intaking amount of groundwater in normal Groundwater source heat pump.

  • PDF

Heat Transfer Augmenttaion by use of Wire Mesh-Screens in Impinging Water Jet (와이어 망을 이용한 충돌 수분류의 열전달 증진)

  • Yun, S.H.;Lee, J.S.;Choi, G.G.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.43-51
    • /
    • 1999
  • Axisymmetric circular water jet impinges against rectangular heated surface with uniform hear flux and wire-mesh screens are set up in the nozzle-to-heater space to augment heat transfer. In the free jet region to be used them, pressure drop and intensive turbulence flow was brought up. When water jet system is not used wire-mesh screens, maximum heat transfer appears in the stagnation point and the secondary maximum appears X/D=4 but it disappears when they are is used. In the low velocity(Vo<6.0m/s), coarse mesh-screen enhanced heat transfer but fine mesh-screens inpeded heat transfer. In the high velocity(Vo>6m/s), all of them enhanced heat transfer. Average Nusselt number of experimental system to be used wire-mesh screens was promoted $4{\sim}6$times than that of simple water jet system. The stagnation heat transfer of experimental system to be used wire-mesh screens was augmented 6times that of simple water jet system.

  • PDF

The Optomotor Response of Killifish and Yellowtail (송사리와 방어의 시각운동반응)

  • Jang, Choong-sik;Lee, Byoung-gee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 1983
  • The authors carried out an experiment to find the optomotor response of killifish, Orizias latipes(TEMMINCK et SCHLEGEL) and Yellowtail, Seriola quinqueradiata (TEMMINCK et SCHLEGEL) according to the colors of the netting pattern on the visual screen and the revolving velocities of the visual screen. The experimental water tank was made of 0.5 cm thick transparent acryl in the cylindrical shape (100R$\times$42H cm). The water level in the tank was maintained 30cm high from the bottom. The colors of the netting pattern (mesh size: 19.1cm, width of netting twine: 1.5cm, hanging ratio: 84%) on the three visual screens were black, red and green respectively. The revolving velocities of the visual screen were controlled by pulley, bevel gear and variable speed motor in three steps; slow (15.0cm/sec), middle (37.4cm/sec) and high (62.9cm/sec). The fish was put into the water tank before each experiment and released in it for 30 minutes in order to acclimatize itself to the tank. The visual screen was revolved for 4 minutes per each experiment, at first the fish was released for 1 minute, and then the behavior of the fish was observed for 3 minutes. In the course of clockwise and counter clockwise experiments, 10 minutes-pause was given for the rest. The behavior of the fish was observed by video system, and rounding number and swimming speed of the fish were analysed. The results obtained are as follows: (1) Optomotor response rate of Killifish and yellowtail were 95% and 94% respectively. (2) Response of the fish according to the colors of the netting pattern on the three visual screens was best in black, and second in red and third in green. (3) Response of the fish according to the revolving velocities of the visual screen was best in high speed, and second in middle speed and third in slow speed.

  • PDF

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF