• Title/Summary/Keyword: Water Resistivity

Search Result 383, Processing Time 0.022 seconds

Interpretation of Soft Ground Deformation under Embankment using the Electrical Resistivity Survey (전기비저항탐사를 이용한 성토하부 연약지반의 변형 해석)

  • Kim, Jae-Hong;Hong, Won-Pyo;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.117-124
    • /
    • 2011
  • Soil deformations such as settlement, heaving and lateral flow have frequently happened on marine reclaimed soft grounds due to embankment filling or banking. The electrical resistivity survey was applied to investigate on ground surface such soil deformation without disturbance of ground. A test embankment was performed to assess soil deformation in marine reclaimed soft grounds, where was located at Sihwa area in western coast of Korean peninsula. The soft ground was composed of clayey sediments. After embankment filling, the boundary of soil deformation affected by the filling could be investigated with application of the electrical resistivity survey. The result of electric resistivity survey shows that the extent of deformation is about 5 m laterally to the southern direction of embankment and about 5~6 m vertically in depth, which is about 1-1.2 times of embankment height. This shows that the electric resistivity survey can be applied to interpret the ground deformation in a soft ground region.

A Proposal for Construction Plan of Electric Corrosion from Measurement and Analysis for Earth Resistivity of Ha-Nam IC Water Pipe Line (하남IC 상수도관로 대지비저항 측정 및 분석에 따른 전기방식 시공방안 제시)

  • Shin, Gang-Wook;Lee, Eun-Chun;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.355-357
    • /
    • 2000
  • Measurement used electricsal sounding(MacOHM 2115, Japan) for grounding resistance of Jung-Bu highway Ha-Nam IC about 500m. To applied measurement method is fall of potential method and analysis earth resistivity used ESII(Electrical Sounding Interactive Interpretation) program. This result propose for construction plan of electric corrosion.

  • PDF

High Resistivity Characteristics of the Sinter Dust Generated from the Steel Plant

  • Lee, Jae-Keun;Hyun, Ok-Chun;Lee, Jung-Eun;Park, Sang-Deok
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.630-638
    • /
    • 2001
  • The electrical resistivity of sinter dusts generated from the steel industry and coal fly ash from the coal power plant has been investigated using the high voltage conductivity cell based on JIS B 9915 as a function of temperature and water content. Dust characterization such as the chemical composition, size distribution, atomic concentration, and surface structure has been conducted. Major constituents of sinter dusts were Fe$_2$O$_3$(40∼74.5%), CaO (6.4∼8.2%), SiO$_2$(4.1∼6.0%), and unburned carbon (7.0∼14.7%), while the coal fly ash consisted of mainly SiO$_2$(51.4%), Al$_2$O$_3$(24.1%), and Fe$_2$O$_3$(10.5%). Size distributions of the sinter dusts were bi-modal in shape and the mass median diameters (MMD) were in the range of 24.7∼137㎛, whereas the coal fly ash also displayed bi-modal distribution and the MMD of the coal fly ash was 35.71㎛. Factors affecting resistivity of dusts were chemical composition, moisture content, particle size, gas temperature, and surface structure of dust. The resistivity of sinter dusts was so high as 10(sup)15 ohm$.$cm at 150$\^{C}$ that sinter dust would not precipitate well. The resistivity of the coal fly ash was measured 1012 ohm$.$cm at about 150$\^{C}$. Increased water contents of the ambient air lowered the dust resistivity because current conduction was more activated for absorption of water vapor on the surface layer of the dust.

  • PDF

Electrical Characteristics against Frequency and Concentration of Contaminated Soils by Mercury and Arsenic (수은과 비소로 오염된 시료의 측정주파수와 농도 변화에 따른 전기적 특성)

  • Son, Young-Hwan;Bong, Tae-Ho;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.6
    • /
    • pp.15-24
    • /
    • 2008
  • In general, ground pollution can be classified with soil pollution and underground water pollution. And ground pollution contaminates the land with garbage dumps and other harmful waste products as heavy metals that can also eventually enter our water supply. This study was conducted to define a characteristics of the electrical resistivity and the permittivity of weathered soil that was contaminated with heavy metals as Mercury and Arsenic. It is not easy whether contamination of soil as subsurface contamination is decided or not and at an early stage especially do that. Therefore the electrical resistivity and the permittivity were used to make up for this defects. These methods are more economical and more effective than the existing methods. And variation of the electrical resistivity and the permittivity values were found against the change of concentration of Mercury and Arsenic aqueous solutions and measuring frequency. These analyzed results indicate that the electrical resistivity and the permittivity tend to decrease against increasing measuring frequency. The electrical resistivity and the permittivity are also found to show the function of frequency.

Delineation of a fault zone beneath a riverbed by an electrical resistivity survey using a floating streamer cable (스트리머 전기비저항 탐사에 의한 하저 단층 탐지)

  • Kwon Hyoung-Seok;Kim Jung-Ho;Ahn Hee-Yoon;Yoon Jin-Sung;Kim Ki-Seog;Jung Chi-Kwang;Lee Seung-Bok;Uchida Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.50-58
    • /
    • 2005
  • Recently, the imaging of geological structures beneath water-covered areas has been in great demand because of numerous tunnel and bridge construction projects on river or lake sites. An electrical resistivity survey can be effective in such a situation because it provides a subsurface image of faults or weak zones beneath the water layer. Even though conventional resistivity surveys in water-covered areas, in which electrodes are installed on the water bottom, do give high-resolution subsurface images, much time and effort is required to install electrodes. Therefore, an easier and more convenient method is sought to find the strike direction of the main zones of weakness, especially for reconnaissance surveys. In this paper, we investigate the applicability of the streamer resistivity survey method, which uses electrodes in a streamer cable towed by ship or boat, for delineating a fault zone. We do this through numerical experiments with models of water-covered areas. We demonstrate that the fault zone can be imaged, not only by installing electrodes on the water bottom, but also by using floating electrodes, when the depth of water is less than twice the electrode spacing. In addition, we compare the signal-to-noise ratio and resolving power of four kinds of electrode arrays that can be adapted to the streamer resistivity method. Following this numerical study, we carried out both conventional and streamer resistivity surveys for the planned tunnel construction site located at the Han River in Seoul, Korea. To obtain high-resolution resistivity images we used the conventional method, and installed electrodes on the water bottom along the planned route of the tunnel beneath the river. Applying a two-dimensional inversion scheme to the measured data, we found three distinctive low-resistivity anomalies, which we interpreted as associated with fault zones. To determine the strike direction of these three fault zones, we used the quick and convenient streamer resistivity.

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.

Monitoring the performance of a celite-based filter by using electrical resistivity and permeability measurements (전기비저항과 투수계수 측정을 통한 celite가 가미된 필터의 투과 성능 모니터링)

  • Kim, Kyu-Won;Kwon, Tae-Hyuk;Cho, Gye-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.673-676
    • /
    • 2009
  • Non-point pollutants, which mainly originate from high traffic roads and rural areas, contaminate the environment by flowing into various rivers and lakes and thus are of interest as an environmental issue. Accordingly, efforts have been made to design and maintain efficient filter systems for the control of the non-point pollutants. Meanwhile, clay-type materials are widely used for the absorption of chemicals included in pollutants and the absorption performances of various clays have been reported in the literature. Thus, the present study proposes a non-destructive monitoring method for the performance of a clay-type filter using electrical resistivity measurement. A series of experimental tests is performed on celite-based particulate filters with infiltrating non-point source pollutants having the same characteristics as pollutants on high traffic roads. Each test measures permeability, resistivity of the filter materials and resistivity of the filtrated water. As the particulate filter materials filtrate pollutants and absorb heavy chemicals (e.g., $Cr^{6+}$, lead, nickel, among others), ionic concentration increases resulting as the electrical resistivity decrease. When the filter systems approach the end of their lifetime, the electrical resistivity of the filter material converges to a very low value due to lowered filter absorption efficiency. Hence, the electrical resistivity of the filtrated water also converges to a low value due to high concentrations of heavy metals. The permeability converges to a very low value because of significantly reduced porosity due to clogging and absorption of pollutants on the filter material. The experimental results show that electrical resistivity monitoring of filter materials is a promising approach to estimation of filter performance and its life expectancy.

  • PDF

A study on induced polarization characteristics of sand and clay for alluvium investigation (충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.179-184
    • /
    • 2008
  • Silt or clay alluvium fully saturated with water generally shows low resistivity. Sometimes it is believe that the low resistivity layer is considered as good aquifer but this makes problems in the development of groundwater. To overcome this problem, we adopted induced-polarization(IP) method with resistivity method. Laboratory experiments and resistivity/IP field surveys with non-polarization electrodes were conducted for the study. Laboratory experiments shows that the increase of clay contents in the sample mixed with sand and clay give low resistivity and high chargeability. We used this experiment results in the interpretation of resistivity/IP field data which were obtained in riverbank filtration. Finally, the layer which has low resistivity and chargeabilty would be regarded as a good aquifer for the development of groundwater intake.

  • PDF

Characteristic Analysis for Resistivity of Concrete (콘크리트의 저항률 특성 분석)

  • Kim, Sung-Sam;Choi, Jong-Kyu;Kim, Jae-Sung;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.457-459
    • /
    • 2006
  • In this paper was analyzed and compared the resistivity characteristic of concrete between moisture condition and dry condition to measure the variation of resistivity by water after making concrete scale block. The resistivity was decreased when the moisture of concrete block was gradually increased.

  • PDF

A Study on the Evaluation of the Corrosive Environment of Reinforcement Bar by Concrete Layer Resistivity (콘크리트 층간비저항에 의한 철근의 부식환경 평가에 관한 연구)

  • Lim, Young-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.43-44
    • /
    • 2012
  • Deterioration factors such as CO2 and chloride ions cause steel corrosion in RC structures. The diffusion of these factors depends on the water content in concrete. To examine the moisture condition of concrete, this research considers the availability of the steel effect ratio, which is calculated by Resistivity Estimation Model (REM). It is concluded that the steel effect ratio is expected to be available as a quantitative evaluation method in the assessment of concrete layer resistivity.