• 제목/요약/키워드: Water Quality Measurement

검색결과 533건 처리시간 0.027초

서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구 (A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul)

  • 이진효;이수현;김정연;김지희;정숙녀;김진아;오석률;김익수;신진호;어수미;정권;이진숙
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석 (Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis)

  • 이학종;윤태종;윤영일
    • Ultrasonography
    • /
    • 제32권1호
    • /
    • pp.59-65
    • /
    • 2013
  • 목적: 본 연구는 초음파 조영제를 직접 합성하고 그 크기 및 소멸 시간 등의 특성을 분석하며, 기존의 초음파 조영제와의 영상을 비교하여 앞으로 초음파 조영제를 매개로 한 영상 유도 하 약물 및 유전자 치료제의 전달 시스템 구축의 기본을 갖추고자 한다. 대상 및 방법: 초음파 조영제는 21마이크로 몰의 DPPC(1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), 9 마이크로 몰의 콜레스테롤, 1.9 마이크로 몰의 DCP(Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$) 및 클로로포름 및 SF6 기체를 이용하여 합성하였다. 약 12-24시간의 동결건조 후에 초음파 조영제는 SF6 기체와 초음파 처리(sonication) 법을 이용하여 합성하였고 그 초음파 조영제의 크기는 압출기를 이용하여 일정한 크기로 조정하였다. 합성된 초음파 조영제는 동적 광산란 측정법(dynamic light scattering measurement)을 이용하여 그 크기를 분석하였다. 한편 합성한 초음파 조영제의 소멸 양상을 평가하기 위하여 광학 현미경을 이용하여 그 숫자를 합성 직후, 12시간, 24시간, 36시간, 48시간, 60시간, 72시간 및 84시간 후에 평가하였다. 초음파 조영제로서의 효과를 평가하기 위하여 모형을 만들어 현재 임상적으로 사용되고 있는 초음파 조영제와 그 에코를 비교 분석하였다. 결과: 초음파 조영제는 동결건조-초음파 처리 방법을 통하여 성공적으로 합성 할 수 있었다. 합성된 초음파 조영제는 154.2 nm의 정점 (peak)에서 가장 많이 분포하였으며 합성 후 24시간부터는 입자의 숫자들이 감소하는 양상을 보였다. 소노뷰와 합성된 초음파 조영제의 에코밝기는 유의한 차이를 보이지 않았으나 소노뷰와 생리식염수 및 합성된 초음파 조영제와 생리식염수의 에코 밝기는 통계적으로 유의한 차이를 보였다 (p < 0.01). 결론: 본 연구를 통하여 초음파 조영제를 직접 합성할 수 있는 방법을 습득할 수 있었고 그 크기 및 특성을 분석할 수 있었다.

PET/CT 검사에서 SharpIR 재구성 방법의 평가 (Evaluation of SharpIR Reconstruction Method in PET/CT)

  • 김정열;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.12-16
    • /
    • 2012
  • 서론: 종래의 PET 영상 재구성에 있어서 FBP 등에 비해 3차원 반복 재구성 방법이 일반적으로 대체하고 있으며, 이것은 검출기 기하학적 특성과 완벽한 3차원 산란 평가 및 저잡음 randoms 평가 등의 더 진보된 재구성 알고리즘을 제공하고 활용되고 있다. 최근에 SharpIR알고리즘은 3차원 반복 재구성 알고리즘으로 PET 검출기 응답 정보를 통합하여 PET 영상의 잡음을 효과적으로 감소시켜 대조도를 향상 시키기 위한 것으로 알려지고 있다. 본 연구에서는 새로운 반복 시스템 모델인 SharpIR에 대한 성능 평가와 임상에서의 적용 가능성에 대해 알아보고자 한다. 실험재료 및 방법: 검출기 응답에 대한 분해능을 측정하기 위해 유리관(내경 1.1 mm, 두께 0.2 mm)에 $^{18}F$-FDG (250 MBq/mL)을 주입하여 축 방향 시야의 중심과 축 방향으로 5, 10, 15, 20 cm만큼 떨어진 지점에서 획득하였고 VUE point HD와 VUE point HD-SharpIR로 재구성하여 각각의 영상에서 반치폭을 구하였다. 또한 영상품질평가로 image quality phantom (NU2-2001)을 이용하여, 여러 개의 각각 다른 반지름을 가지는 원형구에 cold (직경 28, 37 mm)와 ho (직경 10, 13, 17, 22 mm)부분을 나누어 배경잡음을 주고 영상의 대조도를 평가하였다. 획득된 영상은 VUE point HD와 VUE point HD-SharpIR로 재구성을 하였다. 임상실험에서는 전신검사를 시행받은 환자 중 병소가 있는 환자 10명을 대상으로 VUE point HD와 VUE point HD-SharpIR로 재구성하였다. 이때 iterations을 1~10까지 변경하여 병소 부위와 간 부위에 관심영역을 설정하여 대조도를 평가하였다. 결과: VUE point HD로 재구성한 영상에서는 시야 중심으로부터 축방향 거리 증가와 함께 반치폭이 함께 증가하였지만 VUE point HD-SharpIR로 재구성한 영상에서는 거리가 증가하여도 일정한 반치폭을 나타냈다. 대조도는 팬텀 실험과 임상 실험에서 VUE point HD-SharpIR이 VUE point HD보다 대조도의 향상을 나타냈다. 결론: 검출기 시스템 응답에 대한 더 많은 정보를 포함시킴으로써 SharpIR 알고리즘은 VUE point HD에서 사용되는 기본 모델의 정확성을 향상시켰다. 또한 SharpIR은 VUE point HD보다 각각의 복셀에 관련된 더 많은 측정 위치를 가지는 시스템 모델이기 때문에 더욱 정교한 재구성 모델의 결과를 나타내기 위해 더 많은 반복이 걸린다. 결론적으로 SharpIR은 PET 영상에서 대조도를 향상시켰고 임상에서 적용할 수 있는 최적화된 재구성 조건을 알아보기 위해 종단적 연구를 통해 적용한다면 임상에서 유용하게 사용될 것이다.

  • PDF

국립공원(國立公園) 자연경관(自然景觀)의 계량적(計量的) 분석(分析)을 통(通)한 경관관리(景觀管理) 개선방안(改善方案)에 관(關)한 연구 (A Study on Proposal of Landscape Management Improvement on the Quantitative Analysis of National Parks)

  • 김세천
    • 한국산림과학회지
    • /
    • 제80권1호
    • /
    • pp.32-41
    • /
    • 1991
  • 우리나라 대표적(代表的)인 산악형국립공원(山岳型國立公園)이라 할 수 있는 지리산(智異山) 산림(山林)의 시각자원(視覺資源)을 대상(對象)으로 시각자원관리(視覺資源管理)를 위한 객관화(客觀化)된 정량적(定量的)인 기초자료(基礎資料)를 제시(提示)하는 것을 목적(目的)으로 설정(設定)된 가설(假設)과 실험(實驗)에 의한 검증과정(檢證過程)을 실시(實施)하였다. 심리량분석(心理量分析)을 위해 S.D Scale 측정(測定)에 의한 공간(空間)의 이미지구조(構造)를 인자분석(因子分析) Algorithm을 통(通)하여 밝혔으며 시각적(視覺的) 선호도(選好度) 측정(測定)을 실시(實施)하여 결정인자추출(決定因子抽出)과 각(各) 인자(因子) 상호간(相互間) 상대적(相對的) 중요성(重要性)을 구명(究明)하였다. 국립공원(國立公園)의 자연경관(自然景觀)과 융화(融和)를 전제(前提)로 한 수림(樹林), 하늘, 수면(水面), 기암괴석(奇岩怪石) 등(等)의 자연요소(自然要素)와 사찰건물(寺刹建物) 등(等)의 요소(要素)를 지닌 시각요소(視覺要素)가 긍정적(肯定的)으로 높게 나타날 수 있도록 대상지향성(對象志向性)과 형수성(亨受性)을 높일 수 있는 체험(體驗)의 장(場)을 이루게 하여 경관적(景觀的) 가치(價値)를 높이며, 인공구조물(人工構造物) 요소(要素)에 대(對)한 보다 계획적(計劃的)이고 체계적(體系的)인 설치(設置) 등(等)의 시각자원관리(視覺資源管理) 기법(技法)이 필요(必要)하다 하겠다. 자연경관내(自然景觀內) 인위적(人爲的) 이질요소(異質要素)가 보완적(補完的), 융합적(融合的)으로 작용(作用)하는 공간(空間)에서는 시각적(視覺的) 표현(表現)의 다양성(多樣性)과 양감적(量感的) 요소(要素) 및 주변경관(周邊景觀)과 일관(一貫)된 맥락(脈絡)을 유지(維持)하는 분배(分配)와 연결(連結)의 상호(相互) 관계(關係)를 고려(考慮)하여 도입(導入)한다. 또한 자연(自然)과 인공(人工)의 균형(均衡)이 고려(考慮)되는 시각적(視覺的) 연속성(連續性), 구조물(構造物)의 형태적(形態的) 간결성(簡潔性), 동화성(同化性), 강조성(强調性), 이질요소(異質要素)의 통일성(統一性) 및 비례(比例) 등의 배열미(配列美)에 대(對)한 종합적(綜合的)인 기준설정(基準設定)이 요구(要求)된다 하겠다.

  • PDF

DISEASE DIAGNOSED AND DESCRIBED BY NIRS

  • Tsenkova, Roumiana N.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1031-1031
    • /
    • 2001
  • The mammary gland is made up of remarkably sensitive tissue, which has the capability of producing a large volume of secretion, milk, under normal or healthy conditions. When bacteria enter the gland and establish an infection (mastitis), inflammation is initiated accompanied by an influx of white cells from the blood stream, by altered secretory function, and changes in the volume and composition of secretion. Cell numbers in milk are closely associated with inflammation and udder health. These somatic cell counts (SCC) are accepted as the international standard measurement of milk quality in dairy and for mastitis diagnosis. NIR Spectra of unhomogenized composite milk samples from 14 cows (healthy and mastitic), 7days after parturition and during the next 30 days of lactation were measured. Different multivariate analysis techniques were used to diagnose the disease at very early stage and determine how the spectral properties of milk vary with its composition and animal health. PLS model for prediction of somatic cell count (SCC) based on NIR milk spectra was made. The best accuracy of determination for the 1100-2500nm range was found using smoothed absorbance data and 10 PLS factors. The standard error of prediction for independent validation set of samples was 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. It has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. From the spectral changes, we learned that when mastitis occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk. It was consistent with the results we obtained further when applied 2DCOS. Two-dimensional correlation analysis of NIR milk spectra was done to assess the changes in milk composition, which occur when somatic cell count (SCC) levels vary. The synchronous correlation map revealed that when SCC increases, protein levels increase while water and lactose levels decrease. Results from the analysis of the asynchronous plot indicated that changes in water and fat absorptions occur before other milk components. In addition, the technique was used to assess the changes in milk during a period when SCC levels do not vary appreciably. Results indicated that milk components are in equilibrium and no appreciable change in a given component was seen with respect to another. This was found in both healthy and mastitic animals. However, milk components were found to vary with SCC content regardless of the range considered. This important finding demonstrates that 2-D correlation analysis may be used to track even subtle changes in milk composition in individual cows. To find out the right threshold for SCC when used for mastitis diagnosis at cow level, classification of milk samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two levels of SCC - 200 000 cells/$m\ell$ and 300 000 cells/$m\ell$, respectively, were set up and compared as thresholds to discriminate between healthy and mastitic cows. The best detection accuracy was found with 200 000 cells/$m\ell$ as threshold for mastitis and smoothed absorbance data: - 98% of the milk samples in the calibration set and 87% of the samples in the independent test set were correctly classified. When the spectral information was studied it was found that the successful mastitis diagnosis was based on reviling the spectral changes related to the corresponding changes in milk composition. NIRS combined with different ways of spectral data ruining can provide faster and nondestructive alternative to current methods for mastitis diagnosis and a new inside into disease understanding at molecular level.

  • PDF

농업용 호소의 조류 발생 진단을 위한 간편 도구의 개발 (Development of simple tools for algal bloom diagnosis in agricultural lakes)

  • 남귀숙;이승헌;조현정;박주현;조영철
    • 환경생물
    • /
    • 제37권3호
    • /
    • pp.433-445
    • /
    • 2019
  • 본 연구는 농업용 호소의 녹조발생을 간편하고, 효율적으로 진단할 수 있는 도구를 개발하고자 하였다. 2018년 4월~10월 동안 15개 농업용 호소에서 채취된 182개의 시료를 이용하여 식물플랑크톤 현존량을 반영할 수 있는 수질 이화학적 항목을 살펴보고자 식물플랑크톤과 TN, TP, Chl-a, SD 등의 상관계수(r)를 분석한 결과, 총 식물플랑크톤 현존량은 Chl-a (r=0.666), SD (r= -0.351)와 높은 상관관계, 남조류와 유해 남조류 현존량 역시 Chl-a과 각각 r=0.664, r=0.353, SD와 각각 r= -0.340, r= -0.338로 유의성 있는 상관관계를 보여주었으나 TN, TP의 항목과는 유의한 상관관계가 나타나지 않았다. Chl-a 농도는 SD와 r= -0.434의 상관관계를 보여주어 식물플랑크톤 현존량보다 높은 유사성을 나타냈으므로, 조류경보제에서 사용하는 유해 남조류 현존량 분석을 대신하여 녹조예찰을 위한 진단 요소항목으로 Chl-a와 SD를 선정하고 실시간 SD 실측 값을 이용하여 진단을 할 경우 그 결과에 대한 유의성이 있는 것으로 판단되었다. 녹조진단 도구는 SD와 탁도 측정방법을 변형한 역원뿔 모양의 용기와 녹조판단조견표로 구성되어 있으며, 현장수를 채취하여 녹조발생 정도에 따라 용기 내에 보이는 원형환의 개수 또는 각 원형환에 표시된 숫자를 관찰하고, 조류의 색도를 녹조판단조견표와 비교하여 최종 녹조단계를 판별할 수 있도록 하였다. 또한, 정확한 진단을 위해 Chl-a 농도와 원형환의 수에 근거한 4단계 진단 기준과 Hexa 코드명이 표기된 부채모양의 조견표를 제시하여 한가지 방법에 따른 변수와 오차를 보완하고 판단의 편리성을 함께 제공하였다. 이를 통해 농업용 호소의 녹조진단을 용이하게 할 수 있을 것으로 기대되며, 녹조관리방안 수립을 효율화하여 녹조로부터 안전하고 건강한 농업용수 확보가 가능할 것으로 판단된다.

초등학생의 보건관리 만족도와 태도에 관한 연구 - 양호교사 유무를 중심으로 - (A Study on the Health Care Satisfaction and Attitude of Elementary School Students - by the presence or absence of nurse teacher -)

  • 박동권;박영수
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제1권2호
    • /
    • pp.49-71
    • /
    • 2000
  • The purpose of this study was to serve as a basis for school health care of better quality, by making a comparative analysis of the health care satisfaction and attitude of elementary school students in consideration of their general characteristics and the presence or absence of nurse teacher. The subjects in this study were 919 selected six graders in 16 elementary schools in the city of Tongduchun, Koyang and Euijungbu, Yangju-kun and Yeunchun-kun. A survey was conducted with questionnaire designed for measurement of health care satisfaction and attitude. As a result of analyzing the data collected from June 1 through 15, 2000, the conclusions were as follows. 1) As for the general characteristics of the students investigated, the subjects included 513 boys(55.8%) and 406 girls(44.2%). The schools where 390(42.4%) students attended were located in municipal area, and the schools where 529(57.6%) students attended were located in kun area. 608(66.2%) students had a nurse teacher at their schools, while 311(33.8%) students had no nurse teacher. 498(54.2%) had an experience to use the health room this year, but 421(45.8%) had no such an experience. Their mean school life satisfaction was scored $3.42{\pm}.71$, above the average. And their health condition was rated $3.81{\pm}.87$, which implied they tended to be in good health. 2) The mean satisfaction at the health room operation was scored $3.33{\pm}.71$, above the medium level. What they were most satisfied with($4.02{\pm}1.08$) was, among the health room facilities, that there were beds. But they expressed the least satisfaction($2.83{\pm}1.17$) at the location of health room. The presence or absence of nurse teacher made a significant difference to their satisfactionat health room operation, because the students in schools with nurse teacher showed greater satisfaction($3.42{\pm}.72$) than the others in schools with no nurse teacher did($3.15{\pm}.66$). 3) Concerning their attitude to use the health room in case of disease or accident occurrence, a lot of students in schools with a nurse teacher, who had ever suffered from indigestion, headache or traumatic injury, used the health room. In schools with no nurse teacher, there was a tendency to talk to their class teachers(p<.001). The recognition of the necessity for health counseling was generally on a medium level. The counselor whom they wanted to discuss health problem with was family or friend in the largest cases. Few students discussed with class teachers in case there was a nurse teacher in school. Instead, some of them discussed with friend, family or nurse teacher, and there was a significant difference between them(p<.001). 4) The mean satisfaction at health, sanitation and environmental management was rated $3.20{\pm}.90$, above the average. The classroom lighting gave them the best satisfaction with $3.67{\pm}1.07$, but the satisfaction at toilet cleanness and disinfection was not good with $2.83{\pm}1.19$. By the presence or absence of nurse teacher, those who had a nurse teacher expressed better satisfaction at water supply facilities including hot water than the others who had no nurse teacher did(p<.001). But no significant difference was observed in the other items. 5) The health education satisfaction was rated $3.19{\pm}.99$, which was on a medium level. By item, the mean satisfaction level was $3.36{\pm}1.19$ at nurse teacher's explanation about treatment, $3.13{\pm}1.15$ at the frequency of health education, and $3.08{\pm}1.16$ at the explanation on the cause of disease. By the presence or absence of nurse teacher, the students with nurse teacher showed significantly better satisfaction at every factor0(p<.001). 6) Regarding health education attitude, their recognition of the need for school health education was scored $3.89{\pm}.96$. Those who had a nurse teacher felt it more necessary($3.96{\pm}.92$), yet the others who had no nurse teacher felt its necessity a little less($3.74{\pm}1.01$). The most preferred thing for them to learn in health education was first aid, followed by sex education, obesity prevention, safety accident prevention in school and outdoors, smoking-related health, good use of leisure time, and environmental pollution cause in the order named. According to the presence or absence of nurse teacher, there was a significant difference in sex education(p<.01), but no significant disparities were found in the other factors. The most preferred person who would offer health education was a lecturer from the outside(45.8%) and nurse teacher(45.4%). Their preference for class teacher as a person in charge of health education was just 8.8%. But the presence or absence of nurse teacher didn't produce any differences to their preference for a person in charge of health education.

  • PDF

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

정지궤도 해색탑재체(GOCI) 자료 검정을 위한 사전연구 (Prelaunch Study of Validation for the Geostationary Ocean Color Imager (GOCI))

  • 유주형;문정언;손영백;조성익;민지은;양찬수;안유환;심재설
    • 대한원격탐사학회지
    • /
    • 제26권2호
    • /
    • pp.251-262
    • /
    • 2010
  • GOCI(Geostationary Ocean Color Imager) 표준자료의 지속적인 품질관리를 위해서는 위성 운용기간 중 궤도상 복사보정, 대기보정 단계를 거쳐야 되며 해수환경 분석 알고리즘에 대한 검보정도 지속적으로 이루어져야 한다. GOCI의 복사, 대기, 해양환경 자료에 대한 검보정은 부이나 고정 플랫폼을 이용한 수온, 염분, 해수 광특성, 형광, 및 탁도 관측과, 주기적으로 해양환경 자료 수집을 통하여 실시한다. 이를 위하여 동중국해에 위치하고 있는 이어도 종합해양과학기지에 설치된 광학 관측 장비와 현장 관측의 복사자료를 상호 비교해 보았으며, GOCI 표준자료의 검정에 앞서 SeaWiFS 복사량과 비교하여 검정하였다. 해수출 광량은 현장관측에서 얻어진 광과 광량과는 약간의 차이를 보였지만, 흡광영역이 매우 잘 일치하고 있으며 스펙트럴 이동은 없는 것으로 판단된다. 이어도 종합해양과학기지의 분광측정기와 SeaWiFS의 전 밴드에서 얻어진 해수출 광량을 비교한 결과 평균 25% 정도의 에러가 발생했지만, 대기보정 밴드를 제외하면 절대오차가 11% 정도로 상당히 낮아진다. 이것은 SeaWiFS 표준 대기보정 방법의 문제점으로 GOCI 검보정 연구에서 고려되어 보완 되어야 할 것으로 판단된다. 이와 더불어 독도 지역의 표준 관측치(Reference Target Site) 구축을 통한 검보정 연구를 위하여, 독도 주변 해수의 광 특성과 해양환경 자료는 2009년 8월과 2009년 10월 2차례에 걸쳐서 현장관측을 실시하였다. 독도 주변 해역의 해양 광 특성은 원격반사도의 스펙트럼형태를 기준으로 Case-1 Water 성향이 강한 해수에서 나타나는 특성과 매우 유사하였다. 식물플랑크톤, 부유물질, 용존유기물의 흡광계수 스펙트럼의 형태들은 대체적으로 각 성분별 흡광 스펙트럼 특성을 잘 보여주었다. 또한 MODIS Aqua로부터 산출된 엽록소 농도와 현장관측을 통한 검증에서 위성자료 값들은 잘 일치한다. 위와 같이 현재 진행되고 있는 GOCI 검보정 연구를 통해서 복사, 대기, 해양환경 알고리즘에 대한 문제점이 도출되었고, 차후 검보정 계획에 반영하여 이 부분들에 대한 개선 및 보완이 이루어질 것으로 판단된다.

하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안 (Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant)

  • 김길정;김래현
    • 에너지공학
    • /
    • 제28권2호
    • /
    • pp.18-35
    • /
    • 2019
  • 한국지역난방공사에서 난지 물재생센터의 하수처리 설비로 부터 발생하는 $45,300m^3$/일의 바이오가스를 연료로 1,500 kW, 2대 규모의 엔진 발전기를 운영하고 있다. 그러나 바이오가스 발전 플랜트의 실제 운영 경험이 미미하고, 축적된 기술 및 노하우 부족으로 가스엔진의 잦은 고장과 정지로 많은 경제적 손실이 발생하고 있다. 따라서 이 발전 플랜트의 안정적인 운영을 위한 기술적 근본 대책 마련이 필요한 실정이다. 본 연구에서는 난지 물재생센터의 하수처리장에서 발생하는 바이오가스를 이용한 가스엔진 플랜트의 일련의 공정상의 문제점을 확인하고, 각 단계별 문제점을 최소화 하여 실제 운전의 최적화 방안을 마련하였다. 먼저 고장 정지의 주요 원인인 발생가스의 정제를 위해 현재 사용 중인 활성탄에 대한 성분분석 및 흡착실험을 통해 활성탄의 흡착능력 품질 기준 마련을 위한 여건을 조성하였다. 또한, 불순물을 최소화하기 위한 활성탄의 교체주기의 기준수립, 황화수소 측정주기 강화, 활성탄 국산화, 설비개선 등 바이오플랜트 운영기준 강화 및 개선방안을 적용하여 실제운전에 적용하였다. 그 결과 가스엔진 1호기는 530%, 2호기는 250%의 정상운전 가동시간이 증가되는 운영실적을 보였다. 또한 통풍구의 설비개선을 통해 작업공정을 줄이고, 정상 운전시간과 가동률을 높일 수 있었다. 경제적으로도 77,000천원/년의 매출증대 효과를 나타냈다, 이와 같이 운영기준의 강화 및 개선방안을 적용하여, 바이오가스 플랜트의 고장 정지를 줄이고 가동률을 높여, 안정적인 운영을 하는 것이 현실적인 바이오가스 플랜트의 최적 운영방안으로 판단된다.