• 제목/요약/키워드: Water Purifiers

검색결과 25건 처리시간 0.018초

Evaluation of Microbiological Contamination of Water Purifiers at Two Universities in Chungcheong Region

  • Jin Young Yun
    • 대한의생명과학회지
    • /
    • 제29권4호
    • /
    • pp.256-262
    • /
    • 2023
  • The purpose of this study is to investigate microbial contamination in water purifiers from two universities (A and B) in Chungcheong region and to evaluate about the harmfulness of the isolated bacteria to the human. The degree of microbiological contamination of six water purifiers at university A was investigated three times from July 2018 to September 2019, and nine water purifiers at university B were investigated in 2023. The isolated bacteria were biochemically identified using an API kit and Vitek-2 system, and then the bacteria were identified to the species level using MALDI-TOF MS. In addition, the possibility of human infection of the isolated bacteria was evaluated through a literature search. In July 2018 and September 2019, the number of bacteria isolated inside the faucet was below the acceptable standard for hot water, but exceed for cold water in all water purifiers. In January and September 2019, bacteria exceeding the acceptable standards were isolated nine times from the cold water of six water purifies (a total of 12 water purifiers). Bacteria identified by MALDI-TOF MS included anaerobic bacteria (Clostridium novyi, Clostridium themopalmarium etc.), Gram-positive bacilli (Microbacterium testaceum, Arthrobacter woluwensis etc.), and Gramnegative bacilli (Acinetobacter nosocomialis, Comamonas kerstersii etc.), which are difficult identify by biochemical methods. In conclusion, bacteria exceeding the acceptable standard were isolated from the cold water of most of the water purifiers. Most of the isolated bacteria were low-pathogenic bacteria from natural environment, but opportunistic bacteria that can cause infection in humans were also isolated from some water purifiers.

R435A를 적용한 정수기 냉동시스템의 성능평가 (Performance Evaluation of R435A on Refrigeration System of Water Purifiers)

  • 이요한;강동규;최현주;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2013
  • In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

대체냉매 R430A를 적용한 정수기 냉동시스템의 성능 평가 (Performance of R430A on Refrigeration System of Domestic Water Purifiers)

  • 박기정;이요한;정동수;김경기
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.109-117
    • /
    • 2009
  • In this study, thermodynamic performance of R430A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 76%R152a124% R600a using actual domestic water purifiers. This mixture is numbered and listed as R430A by ASHRAE recently. Test results show that the system performance with R430A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R430A is 13.4% lower than that of HFC 134a. The compressor dome and discharge temperatures and condenser center temperature of R430A are very similar to those of HFC134a at the optimum charge. Overall, R430A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

역삼투막 정수기에서 발생하는 총용존고형물 크리프 현상의 이해 (Understanding on TDS Creep Phenomena of Reverse Osmosis Membranes in Water Purifiers)

  • 강상현;윤성한
    • 멤브레인
    • /
    • 제32권2호
    • /
    • pp.126-132
    • /
    • 2022
  • 정수기는 일반적인 산업용 막여과 수처리 공정과 다르게 운전과 휴지를 반복하는 특성이 있다. 이러한 특징 때문에 역삼투막을 사용하는 정수기의 경우, 재정수시에 정수수의 농도가 정상적인 값보다 높게 나오는 현상(제거율이 정상값보다 낮게 나오는 현상)이 있는데, 이를 "TDS creep"이라고 한다. 본 연구에서는 휴지시간과 농도에 따른 TDS creep 정도를 관찰하였다. 또한, TDS creep 현상을 저감하기 위해 원수 세척, 정수부의 부피 증가 및 정수 세척 방법 등을 시험하였고 이에 대한 실질적인 효과를 관찰하였다. 이러한 방법들 중에 정수수의 세척과 같이 역삼투막의 feed side와 permeate side의 농도차를 최소화하는 것이 TDS creep 현상을 해소하는 궁극적인 해결책임을 확인하였다.

어린이집 급식실 정수기의 미생물학적 오염 평가 (Prevalence of Microbiological Contamination on Water Purifiers at Lunchroom in Child Care Center)

  • 윤미혜;김중범;오혁수
    • 한국식품조리과학회지
    • /
    • 제28권5호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the prevalence of microbiological hazard on water purifiers at lunchroom in child care center was investigated. A total of 49 water purifiers and their purified cold water were sampled to test about the total aerobic bacteria, coliform bacteria, Bacillus cereus, Staphylococcus aureus, and Salmonella spp. Total aerobic bacteria was detected over 2.0 log CFU/mL in 6 out of 49 purified cold water (12.2%), ranged from 2.0 to 2.4 log CFU/mL, and the average number of total aerobic bacteria was showed to be 3.3 log CFU/drain spout. The drain spout turned out to be a major contaminant in water purifier and needs to be improved. Coliform bacteria were also detected in 7 out of 49 cold faucets (14.3%) and 7 out of 49 drain spouts (14.3%), but not detected in purified cold water. All samples were not contaminated with the pathogens tested in this study, except for B. cereus, which was contaminated on 2 out of 49 cold faucets (4.1%) and 4 out of 49 drain spouts (8.2%). All of B. cereus isolates produced enterotoxin, such as heamolysin BL enterotoxin (HBL) or non-heamolytic enterotoxin (NHE). The HBL was detected in 5 out of 6 B. cereus isolates (83.3%), including B. cereus PCF-11 and B. cereus PDS-30 isolate only produced NHE (16.7%). These results showed that the sanitary conditions of cold faucets and drain spouts should be improved promptly.

군산지역 초등학교 정수기 물의 미생물학적 수질 (Microbiological Water Quality of Water Purifiers at Elementary Schools in Gunsan Area)

  • 서란주;박석환;이건형
    • 미생물학회지
    • /
    • 제45권1호
    • /
    • pp.74-81
    • /
    • 2009
  • 2007년 7월부터 12월까지 총 5회 전라북도 군산에 위치한 초등학교의 정수기 물을 대상으로 미생물학적 수질에 대하여 조사하였다. 조사기간 중 정수기 물의 종속영양세균의 분포는 $0{\sim}1.2{\pm}0.2{\times}10^4CFU/ml$의 범주에서 나타났는데, 이 중 최대값은 우리나라 먹는 물 수질기준을 120배 초과하는 값을 나타냈다. 월별 수질기준을 초과하는 정수기 물의 백분율은 7월과 9월에 90%, 10월과 11월에 87.2%, 12월에 93.7%로 조사되었다. 한편 총대장균군과 병원성 세균인 Salmonella와 Shigella는 정수기 물과 수돗물에서 모두 검출되지 않았다. 총 5회의 실험 중 정수기 물에서 분리한 세균을 분자생물학적인 방법으로 동정한 결과, Sphingomonas, Methylobacterium, Caulobacter, Novosphingobium, Bosea, Brevundimonas, Aminobacter, Ralstonia, Mitsuaria, Variovorax, Acidovorax, Massilia, Pseudomonas, Acinetobacter, Aeromonas, Bacillus, Staphylococcus, Brevibacillus, Microbacterium, Lapillicoccus, Micrococcus, Arthrobacter, Janibacter, Flavobacterium, Chryseobacterium, Hymenobacter 등 26개 속이 동정되었다. 검출된 세균의 대부분은 일반 환경에서 다량 존재하는 세균들로서 병원성이 없으나, Pseudomonas fluorescens, Staphylococcus epidermidis, Flavobacterium johnsoniae, Acinetobacter johnsonii 등은 기회감염균으로 면역력이 낮은 초등학교 학생들의 경우 감염의 가능성이 있다.

가정용 정수기 폐필터 재활용 동향에 관한 연구 (A Study on Current Status and Trends of Recycling Used Water Purifier Filters)

  • 신유정;김용인;김정건;염성일;이도균
    • 한국물환경학회지
    • /
    • 제37권5호
    • /
    • pp.398-404
    • /
    • 2021
  • The use of water purifiers has been increasing every year due to increased drinking water safety concerns raised by the water pollution accidents occasionally reported. Currently, more than 10 million water purifiers have been distributed in Korea, and the estimation of the purifier sales reaches two million units per year. As a result, the number of used water purifier filters that must be replaced on a regular basis has gradually increased. However, regardless of the considerations for the capacity of used filters remaining, water purifier filters were replaced and collected at regular intervals. The high cost of disposal of the used filters by landfill or incineration were required. Thus, in this study, the current status and trends of recycling technologies for used water purifier filters were reviewed. It is noted that there was insufficient statistical data to understand the current status of the difference between the number of used water filters discarded and the number of those recycled. Most studies on the recycling of old water purifier filters have concentrated on pretreatment and cleaning methods for sediment filters and membrane filters, with the goal of extending the lifespan of used filters. Further, the study suggested future study directions on the recycling of used water purifier filters, which could be useful information on establishing environmental policy to promote the recycling of used filters.

누수가 발생한 정수기의 위험요소 발굴 및 소손패턴 해석에 관한 연구 (Study on Dangerous Factors and Damage Pattern Analysis of Leaking Water from Water Purifiers)

  • 최충석
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.57-62
    • /
    • 2012
  • The purpose of this paper is to find dangerous factors of a water purifier when water leaks due to inappropriate use and analyze the patterns of damaged parts in order to provide data for the examination of the cause of the problem. If the water purifier is inspected and managed by a non-specialist, when the FLC(Float Level Controller) at the top is inclined, water leakage may occur to the water purifier. The leaked water flows onto the cables and hoses and enters the thermostat terminal, heater, PCB, power supply connection connector, etc., becoming a dangerous factor that may cause a system failure, fire, etc. Due to the water that entered the input terminal, low noise and white smoke were generated at first. However, the flame gradually propagated due to the continuous inflow of moisture. It was found that when moisture reached the PCB, a carbonized conductive path was formed at the varistor terminal, input terminal, semiconductor device terminal, etc., and the flame became larger, which might result in a fire. From the metal microscope analysis of a damaged condenser terminal, it was found that the amorphous structure unique to copper cable disappeared, and voids, boundary surface and disorderly fine particles occurred. Also, in the case of the connector into which moisture penetrated, fusion and deformation occurred at the cable connection clips. The result of analysis of the power supply cable connector using a thermal image camera showed that most of the heat was generated from the cable connection clips and the temperature at the connection center was normal.

Fabrication and Characterization of Onggi Filter for Appropriate Water Treatment Technology

  • Park, Joon-Hong;Kim, Jin-Ho;Cho, Woo-Seok;Han, Kyu-Sung;Hwang, Kwang-Taek
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.114-120
    • /
    • 2017
  • In underdeveloped countries, many people suffer from water shortage due to the absence of water supply service. Although water purifiers have provided support in such situations, it is not easy to maintain water filters without a continuous supply of consumable filters. To obtain a sustainable drinking water source, appropriate technology of water treatment is necessary. Herein, a low cost water purification system was developed using natural raw materials. A non-electric water treatment system was developed using filtration through an Onggi filter, which is a type of Korean traditional earthenware with a microporous surface. The porosity and flux of the prepared Onggi filter were 29.06% and 31.63 LMH, respectively. After purification of water with total dissolved solids of 10.4 mg/L and turbidity of 100 NTU, the total dissolved solids and turbidity of the water treated using the Onggi filter decreased by 12% and 99.8%, respectively.