DOI QR코드

DOI QR Code

Study on Dangerous Factors and Damage Pattern Analysis of Leaking Water from Water Purifiers

누수가 발생한 정수기의 위험요소 발굴 및 소손패턴 해석에 관한 연구

  • 최충석 (전주대학교 소방안전공학과)
  • Received : 2012.02.02
  • Accepted : 2012.05.23
  • Published : 2012.06.30

Abstract

The purpose of this paper is to find dangerous factors of a water purifier when water leaks due to inappropriate use and analyze the patterns of damaged parts in order to provide data for the examination of the cause of the problem. If the water purifier is inspected and managed by a non-specialist, when the FLC(Float Level Controller) at the top is inclined, water leakage may occur to the water purifier. The leaked water flows onto the cables and hoses and enters the thermostat terminal, heater, PCB, power supply connection connector, etc., becoming a dangerous factor that may cause a system failure, fire, etc. Due to the water that entered the input terminal, low noise and white smoke were generated at first. However, the flame gradually propagated due to the continuous inflow of moisture. It was found that when moisture reached the PCB, a carbonized conductive path was formed at the varistor terminal, input terminal, semiconductor device terminal, etc., and the flame became larger, which might result in a fire. From the metal microscope analysis of a damaged condenser terminal, it was found that the amorphous structure unique to copper cable disappeared, and voids, boundary surface and disorderly fine particles occurred. Also, in the case of the connector into which moisture penetrated, fusion and deformation occurred at the cable connection clips. The result of analysis of the power supply cable connector using a thermal image camera showed that most of the heat was generated from the cable connection clips and the temperature at the connection center was normal.

Keywords

References

  1. 김병희 외, "이화학사전", pp. 382-383, 한국사전 연구사, 1996.
  2. 최충석 외 5, "전기화재공학", 도서출판 동화기술, pp. 189-198, 405-409, 2004.
  3. Ki-Jung Park, Dongsoo Jung, "Performance of Alternative Refrigerant R430A on Domestic Water Purifiers", ELSEVIER Energy Conversion and Management Vol.50, pp. 3045-3050, 2009. https://doi.org/10.1016/j.enconman.2009.07.024
  4. 이기연, 최충석, 김동욱, 김향곤, 김동우, "냉온정수기의 전원 제어 시스템 개선에 관한 연구", 대한 전기학회 논문지, Vol. 56P, No. 1, pp. 45-50, 2007. 3
  5. 김동욱, 길형준, 문현욱, 김향곤, 최충석, "사용 환경에 따른 서모스탯의 발열요소에 관한 연구", 한국안전학회 춘계학술대회, pp. 207-212, 2007. 4. 26-27.
  6. 최충석 외 2, "외부화염에 의해 소손된 비닐코드의 단락 특성에 관한 연구", 한국화재소방학회 논문지, Vol. 18, No. 4, pp. 72-77, 2004.
  7. 최충석, 김향곤, "열 스트레스에 의한 비닐절연전선의 탄화 패턴 및 결정 구조의 변화", 대한전기학회 논문지, Vol. 57P, No. 3, pp. 332-337, 2008.
  8. 최충석, "에너지원의 종류에 따른 비닐평형코드 (VFF)의 소손원인 판정기법에 관한 연구", 한국 화재소방학회 논문지, Vol. 25, No. 6, pp. 83-88, 2011.
  9. 石橋 良男, 岸田 順次, "電線の一次, 二次熔融痕鑑 定方法に關する硏究(その1), (その2)", 日本火災 學會硏究發表會槪要集, pp. 83-90, 1990.
  10. 최충석 외 2, "과전류에 의해 용단된 소선의 특성 해석에 관한 연구", 한국산업안전학회지, Vol. 19, No. 1, pp. 60-65, 2004.