• 제목/요약/키워드: Water Flux

검색결과 1,887건 처리시간 0.034초

Organic fouling in forward osmosis (FO): Membrane flux behavior and foulant quantification

  • Xia, Shengji;Yao, Lijuan;Yang, Ruilin;Zhou, Yumin
    • Membrane and Water Treatment
    • /
    • 제6권2호
    • /
    • pp.161-172
    • /
    • 2015
  • Forward osmosis (FO) is an emerging membrane technology with potential applications in desalination and wastewater reclamation. The osmotic pressure gradient across the FO membrane is used to generate water flux. In this study, flux performance and foulant deposition on the FO membrane were systematically investigated with a co-current cross-flow membrane system. Sodium alginate (SA), bovine serum albumin (BSA) and tannic acid (TA) were used as model foulants. Organics adsorbed on the membrane were peeled off via oscillation and characterized by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). When an initial flux of $8.42L/m^2h$ was applied, both flux reduction and foulant deposition were slight for the feed solution containing BSA and TA. In comparison, flux reduction and foulant deposition were much more severe for the feed solution containing SA, as a distinct SA cake-layer was formed on the membrane surface and played a crucial role in membrane fouling. In addition, as the initial SA concentration increased in FS, the thickness of the cake-layer increased remarkably, and the membrane fouling became more severe.

DAF 슬러지의 부상식 농축; 고형물 플럭스법 적용과 영향인자 (Thickening of Sludge from DAF process by Flotation; Application of Solid Flux Theory and Effective Factors)

  • 박상철;한무영;독고석;권순범
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.617-626
    • /
    • 2006
  • Compared with the sludge from gravity sedimentation, it is difficult for operations to settle the sludge occurred from dissolved-air-flotation (DAF). Even though there are some problems in treating DAF sludge with conventional gravity thickeners, those has been used until now. In this study, Solid Flux theory for gravity thickening was applied to the Solid Flux of DAF sludge through flotation in order to develop new methodology for treatment of DAF sludge. Also, characteristics of DAF sludge were investigated. From the experiment results, it was revealed that the higher the polymer dosage, at fixed the solid concentration, the greater the rising velocity becomes. When we applied solid flux theory, the relationship, which is similar to that of gravity thickening, has been achieved. Also, we could find the proper polymer dosage from the rising velocity is about 50 mg/L. Consequently, the limiting solid flux can be derived from the relationship between the total solid flux and the withdrawal velocity of DAF sludge. Furthermore, the factors, such as solid concentrations, bubble volume, pH, zeta potential, and temperature, have effects on the flotation and sedimentation for DAF sludge treatment.

Effect of membrane deformation on performance of vacuum assisted air gap membrane distillation (V-AGMD)

  • Kim, Yusik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.51-62
    • /
    • 2022
  • Vacuum-assisted air gap membrane distillation (V-AGMD) has the potential to achieve higher flux and productivity than conventional air gap membrane distillation (AGMD). Nevertheless, there is not much information on technical aspects of V-AGMD operation. Accordingly, this study aims to analyze the effect of membrane deformation on flux in V-AGMD operation. Experiments were carried out using a bench-scale V-AGMD system. Statistical models were applied to understand the flux behaviors. Statistical models based on MLR, GNN, and MLFNN techniques were developed to describe the experimental data. Results showed that the flux increased by up to 4 times with the application of vacuum in V-AGMD compared with conventional AGMD. The flux in both AGMD and V-AGMD is affected by the difference between the air gap pressure and the saturation pressure of water vapor, but their dependences were different. In V-AGMD, the membranes were found to be deformed due to the vacuum pressure because they were not fully supported by the spacer. As a result, the deformation reduced the effective air gap width. Nevertheless, the rejection and LEP were not changed even if the deformation occurred. The flux behaviors in V-AGMD were successfully interpreted by the GNN and MLFNN models. According to the model calculations, the relative impact of the membrane deformation ranges from 10.3% to 16.1%.

Numerical Study on Simultaneous Heat and Mass Transfer in a Falling Film of Water-Cooled Vertical Plate Absorber

  • Phan, Thanh-Tong;Song, Sung-Ho;Moon, Choon-Geun;Kim, Jae-Dol;Kim, Eun-Pil;Yoon, Jung-In
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.41-47
    • /
    • 2002
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber was developed. The model can predict temperature and concentration profiles as well as the absorption heat and mass fluxes, the total heat and mass transfer rates and the heat and mass transfer coefficients. Besides, the effect of operating condition on absorption mass flux has been investigated, with the result that the absorption mass flux is increased as the inlet cooling water temperature decreases, the system pressure increases and the inlet solution concentration increases. And among the effects of operating parameters on absorption mass flux, the effect of inlet solution concentration is dominant.

  • PDF

비등을 수반하는 발열면에 충돌하는 수분류의 임계열유속에 관한 연구 (Critical Heat Flux of an Impinging Water Jet on a Heated Surface with Boiling)

  • 이종수;김희동;최국광
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.485-494
    • /
    • 2000
  • The purpose of this paper is to investigate a critical heat flux(CHF) during forced convective subcooled and saturated boiling in free water jet system impinged on a rectangular heated surface. The surface is supplied with subcooled or saturated water through a rectangular jet. Experimental parameters studied are a width of heated surface, a height of supplementary water and a degree of subcooling. Incipient boiling point is observed in the temperature of 6${\~}8^{\circ}C$ of superheat of test specimen. CHF depends on jet velocity for various boiling-involved coolant system. CHF also is proportional to the nozzle exit velocity to the power of n, where n is 0.55 and 0.8 for subcooled and saturated boiling, respectively. CHF is enhanced with a higher jet velocity, higher degree of subcooling and smaller width of a heated surface.

EXPERIMENTAL STUDY OF CRITICAL HEAT FLUX WITH ALUMINA-WATER NANOFLUIDS IN DOWNWARD-FACING CHANNELS FOR IN-VESSEL RETENTION APPLICATIONS

  • Dewitt, G.;Mckrell, T.;Buongiorno, J.;Hu, L.W.;Park, R.J.
    • Nuclear Engineering and Technology
    • /
    • 제45권3호
    • /
    • pp.335-346
    • /
    • 2013
  • The Critical Heat Flux (CHF) of water with dispersed alumina nanoparticles was measured for the geometry and flow conditions relevant to the In-Vessel Retention (IVR) situation which can occur during core melting sequences in certain advanced Light Water Reactors (LWRs). CHF measurements were conducted in a flow boiling loop featuring a test section designed to be thermal-hydraulically similar to the vessel/insulation gap in the Westinghouse AP1000 plant. The effects of orientation angle, pressure, mass flux, fluid type, boiling time, surface material, and surface state were investigated. Results for water-based nanofluids with alumina nanoparticles (0.001% by volume) on stainless steel surface indicate an average 70% CHF enhancement with a range of 17% to 108% depending on the specific flow conditions expected for IVR. Experiments also indicate that only about thirty minutes of boiling time (which drives nanoparticle deposition) are needed to obtain substantial CHF enhancement with nanofluids.

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • 제1권4호
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.

시변 고자기장 발생 장치 및 검출회로 (High Magnetic Flux Generator and Detector)

  • 허준;신한호;전성즙
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.167-168
    • /
    • 2018
  • Recently high magnetic flux is used for water treatment and medical treatment. The magnetic flux density reaches up to several Tesla. In this paper, high magnetic flux generator and detector are investigated. The target flux density is 7 Tesla. Proto-types are made and tested.

  • PDF

Steatite 자기의 전기적 특성에 미치는 알칼리 토금속 산화물의 영향 (Effects of Alkaline Earth Oxides on Electrical Characteristics of Steatite Porcelain)

  • 이종근;이병하;전승관
    • 한국세라믹학회지
    • /
    • 제16권1호
    • /
    • pp.31-37
    • /
    • 1979
  • The middle point of composition within the system $MgO-Al_2O_3-SiO_2$ has been studied for applicability as ceramics dielectrics. A Kyul Sung Tale of high purity, magnesia clinker of Sam-wha chemical company, C.P. aluminium oxide, calcium carbonate, red lead, barium carbonate which was made into frit were used the raw materials. A number of steatite ceramics were prepared under carefully controlled condition and the water absorption, linear shrinkage, power factor, dielectric constant and dielectric loss were measured at elevated temperature. When we used magnesia clinker as flux, the quantity of this flux was 0.05mole, sintering temperature was continued for 2 hrs. at 1, 27$0^{\circ}C$. From this conditions, we could get the data whose power factor was 0.142%, water absorption was zero, linear shrinkage was 8.76%, dielectric constant was 5.63, dielectric loss was 0.00799. When we used red lead as flux, the quantity of this flux was 0.033mole and 0.066mole, sintering temperature was continued for 2hrs. at 1, 26$0^{\circ}C$. From this conditions, we could get the data whose water absorption was zero, linear shrinkage was 8.03%, and 8.48%, power factor was 0.136% and 0.062%, dielectric loss was 0.0072 and 0.0037. When we used barium carbonate made into frit as flux, the quantity of this flux was 0.02mole, sintering temperature was continued for 2hrs. at 1, 27$0^{\circ}C$. From this conditions, we could get the data whose water absoption was zero, linear shrinkage was 8.44%, power factor was 0.138%, dielectric constant was 5.69, dielectric loss was 0.0074.

  • PDF

NaA 제올라이트 분리막의 물/에탄올 투과증발 특성 (Pervaporation Characteristics of NaA Zeolite Membrane for Water/Ethanol Mixture)

  • 안효성;이혜련;이용택
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.243-248
    • /
    • 2005
  • 분리막 투과증발은 증류에 비하여 낮은 에너지를 요구하기 때문에 물/유기물 혼합물의 분리에 이용될 수 있으며 공비 혼합물이나 이성질체의 분리에 선호되는 방법이다. 제올라이트 분리막은 고분자 분리막에 비하여 열적, 기계적, 화학적 안정성이 우수하며 NaA 제올라이트 분리막은 큰 친수성을 나타내므로 물/유기물 혼합물로부터 효율적인 물 분리에 적합하다. 본 연구에서는 NaA 제올라이트 분리막을 이용한 투과증발 막분리 공정을 이용하여 물/에탄올 혼합물에서 선택적으로 물을 분리하고자 하였다. 에탄올의 공급 농도가 증가함에 따라 총투과플럭스는 감소하였으며 선택도는 증가한 후 높은 에탄올 농도에서 감소하는 것을 관찰할 수 있었다. 실험 온도의 증가에 따라 총투과플럭스는 증가하였으며 선택도 또한 증가하였지만 높은 에탄올 농도에서는 감소하였다. 160시간 이상의 장기간 실험을 통하여 총투과플럭스와 선택도가 안정적으로 일정함을 확인할 수 있었다. 또한, 본 연구를 통하여 얻어진 NaA 제올라이트 분리막은 증류 및 PVA 계열 고분자 분리막보다 우수한 성능을 나타냄을 알 수 있었다.