• Title/Summary/Keyword: Water Distribution Systems

Search Result 545, Processing Time 0.028 seconds

Distribution of Foodborne Pathogens from Garlic Chives and Its Production Environments in the Southern Part of Korea (남부지방 부추와 재배환경의 식품매개병원균의 분포)

  • Jung, Jieun;Oh, Kwang Kyo;Seo, Seung-Mi;Yang, SuIn;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.5
    • /
    • pp.477-488
    • /
    • 2020
  • Recently, foodborne illness outbreaks linked to fresh produce are being increasingly reported in the United States, the EU, and Korea as well. Some of this increase may be due to improved surveillance, increase in consumption, change in consumers' habits, and complex distribution systems. Garlic chive is a green, fresh-cut vegetable consumed year-round as a nutrition-rich herb in Korea. It is also prone to contamination with foodborne pathogens during pre-harvest, as amendment with high amounts of livestock manure or compost to soil is required in its cultivation. Our aim in this study was to evaluate microbial contamination of garlic chives, garlic chives cultivation soil, compost, and irrigation water in the southern part of Korea. Samples were collected in A, B, and C regions in 2019 and 2020, and 69, 72, 27, and 40 of garlic chives, soil, compost, and irrigated water, respectively, were analyzed for the presence of sanitary indicator bacteria (total aerobic bacteria, coliforms and Escherichia coli), Bacillus cereus, Staphylococcus aureus, pathogenic E. coli, E. coli O157:H7, Listeria monocytogenes, and Salmonella spp. In A, B, and C regions, levels of total aerobic bacteria, coliform, B. cereus, and S. aureus on all samples were between 1.14 and 8.83 log CFU/g, 0.43 and 5.01 log CFU/g, 0.41 and 5.55 log CFU/g, and 1.81 and 6.27 log CFU/g, respectively. B. cereus isolated from garlic chives and environmental samples showed β-hemolysis activity. Incidence of S. aureus in garlic chive and its production environments in 2020 was different from 2019. In this study, B. cereus and S. aureus were the only pathogenic microorganisms detected in all samples. As a result, this work suggests that continuous monitoring in the production and pre-harvest environment is required to improve hthe hygiene and safety of garlic chive.

Comparison of Wind Vectors Derived from GK2A with Aeolus/ALADIN (위성기반 GK2A의 대기운동벡터와 Aeolus/ALADIN 바람 비교)

  • Shin, Hyemin;Ahn, Myoung-Hwan;KIM, Jisoo;Lee, Sihye;Lee, Byung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1631-1645
    • /
    • 2021
  • This research aims to provide the characteristics of the world's first active lidar sensor Atmospheric Laser Doppler Instrument (ALADIN) wind data and Geostationary Korea Multi Purpose Satellite 2A (GK2A) Atmospheric Motion Vector (AMV) data by comparing two wind data. As a result of comparing the data from September 2019 to August 1, 2020, The total number of collocated data for the AMV (using IR channel) and Mie channel ALADIN data is 177,681 which gives the Root Mean Square Error (RMSE) of 3.73 m/s and the correlation coefficient is 0.98. For a more detailed analysis, Comparison result considering altitude and latitude, the Normalized Root Mean Squared Error (NRMSE) is 0.2-0.3 at most latitude bands. However, the upper and middle layers in the lower latitudes and the lower layer in the southern hemispheric are larger than 0.4 at specific latitudes. These results are the same for the water vapor channel and the visible channel regardless of the season, and the channel-specific and seasonal characteristics do not appear prominently. Furthermore, as a result of analyzing the distribution of clouds in the latitude band with a large difference between the two wind data, Cirrus or cumulus clouds, which can lower the accuracy of height assignment of AMV, are distributed more than at other latitude bands. Accordingly, it is suggested that ALADIN wind data in the southern hemisphere and low latitude band, where the error of the AMV is large, can have a positive effect on the numerical forecast model.

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Evidence for Hydrothermal Plume in Manus Basin, SW Pacific: Distribution of Transparency and Hydrogen Sulfide (남서태평양 마누스분지 해역의 열수 plume 증거: 투명도 및 황화수소 분포)

  • Lee, Kyeong-Yong;Park, Yong-Chul;Son, Seung-Kyu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.363-373
    • /
    • 2000
  • To understand and investigate chemical characteristics of thermal environment in the southwestern Paciflc, we have measured hydrological and chemical parameters such as temperature, salinity, transparency, pH, nutrients and hydrogen sulfide (H$_2$S). Samples were collected with CTD-casting at 12 station, in Manus Basin including PACMANUS, DESMOS and Susu Knolls, Hydrothermal systems consist of circulation zones where seawater interacts with rock, thereby changing chemical and physical characteristics of both the seawater and the rock. The altered seawater, called hydrothermal fluid, is injected back into the ocean from the hydrothermal vent fields and forms hydrothermal plumes. Consequently, we detected hydrothermal plume with transparency and sulfide anomalies at PACMANUS and Susu Knolls. Sulfide, as geochemical tracer of hydrothermal plume, ranged 0-3.31 ${\mu}$M, and averaged 0.63 ${\mu}$M in the study area. The height, flux and activity of the plume are affected by circulations in the deep water and the spread of plume follows along the isopycnal surface. Therefore the observed H$_2$S anomaly can provide important clue for the source location and it appears that the targestsource in the PACMANUS is aligned in the north-south direction.

  • PDF

Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater (Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징)

  • 심영대;신규호;좌성훈;김용준
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • In this project, the efficiency of localized heating for micro systems packaging is developed by using a forced potential scheme microheater. Less than 0.2 Mpa contact pressure was used for bonding with a 200 mA current input for $50{\mu}m$ width, $2{\mu}m$ height and $8mm{\times}8mm$, $5mm{\times}5mm$, $3mm{\times}3mm$ sized phosphorus-doped poly-silicon microheater. The temperature can be raised at the bonding region to $800^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3 minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional microheaters. For performing the gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for conducting a gross leak check. The pass ratio of bonded dies was 67%, for conventional localized heating, and 85% for our newly developed FP scheme. The bonding strength was more than 25Mpa for FP scheme packaging, which shows that FP scheme can be a good candidate for micro-scale hermetic packaging.

  • PDF

Distribution Characteristics of DEHA, Carbaryl, and Amitrole in the Fishes and Amphibians from the Major River Systems of Korea (우리나라 주요 수계에 서식하는 어류 및 양서류 체내에 함유된 DEHA, Carbaryl, Amitrole의 분포특성)

  • Joo, Yeo Jeong;Kim, Hye Sook;Kim, Young Bok;Moon, Ji Yong;Jeong, Gi Ho
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.149-156
    • /
    • 2002
  • In this study, the levels of DEHA, carbaryl, and amitrole contained in the fresh water fishes and amphibians were determined. The 31 sampling sites were selected including 29 sites along the several rivers and 2 sites from the well-known wet lands. The rivers consists of the Han, Nakdong, Kum, Youngsan, and other small scaled rivers. DEHA was detected from 10 sites, but carbaryl and amitrole were not detected at any sites. The highest average concentration of DEHA was determined from the Kum River by $52.7{\mu}g/kg$. In the detected 10 sites, the average concentration of DEHA from fishes was $40.0{\mu}g/kg$, and that from amphibians was $8.90{\mu}g/kg$ which indicates that 5 times more DEHA was observed from fishes than amphibians. The detection frequency from fishes was 10/62 while that from amphibians was 2/62, and the highest concentration from fishes was $95.5{\mu}g/kg$ (crucians from Kongjoo) and that from amphibians was $12.1{\mu}g/kg$ (bullfrog from Najoo). Among the 10 detected sites, 6 sites were agricultural area and the other 4 sites were semi-urban area.

Correlation Analysis of Signal to Noise Ratio (SNR) and Suspended Sediment Concentration (SSC) in Laboratory Conditions (실험수로에서 신호대잡음비와 부유사농도의 상관관계 분석)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.775-786
    • /
    • 2017
  • Monitoring sediment flux is crucial especially for maintaining river systems to understand morphological behaviors. Recently, hydroacoustic backscatter (or SNR) as a surrogate to empirically estimate suspended sediment concentration has been increasingly highlighted for more efficient acquisition of sediment dataset, which is difficult throughout direct sediment sampling. However, relevant contemporary researches have focused on wide range solution applicable for large natural rivers where H-ADCPs with relatively low acoustic frequency have been widely utilized to seamlessly measure streamflow discharge. In this regard, this study aimed at investigating hydroacoustical characteristics based on a very recently released H-ADCP (SonTek SL-3000) with high acoustic frequency of 3 MHz in order to capitalize its capacity to be applied for suspended sediment monitoring in laboratory conditions. SL-3000 was tested in a laboratory flume to collect SNR in conjunction with LISST-100X for actual sediment concentration and particle distribution in both sand and silt sediment injection in various amount. Conventional algorithms to correct signal attenuations for water and sediment were carefully tested to validate whether they can be applied for SL-3000. As result of analyzing the SNR-SSC correlation trand, through further study in the future, it is confirmed that SSC can be observed indirectly by using the SNR.

A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas- (제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로)

  • 엄병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

Preparation of Seaweed Calcium Microparticles by Wet-grinding Process and their Particle Size Distribution Analysis (초미세습식분쇄공정의 공정변수에 따른 해조칼슘의 입자크기 분석)

  • Han, Min-Woo;Youn, Kwang-Sup
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.269-274
    • /
    • 2009
  • The main objective of this study was to establish optimum condition of wet grinding process for manufacturing microparticulated seaweed calcium. Process parameters such as concentration of forming agent, rotor speed, bead size, feed rate, and grinding time were adapted during wet-grinding of seaweed calcium. The particle size range of the raw seaweed calcium was 10-20 $\mu$m. The calcium particles were reduced to under 1 $\mu$m as nano scale after grinding. Gum arabic was suitable for forming agent and 5%(w/v) concentration was the most effective in grinding efficiency. A wet-grinding process operated at 4,000 rpm rotor speed, 0,4 mm bead size, and 0.4 L/hr feeding rate, respectively, produced less than 600 mm(>>90%)-sized particles. In batch systems, 8 cycles of grinding showed higher efficiency, but 20 min of grinding time in continuous processing was more efficient to reduce particle size than the batch processing. Based on the result, the optimum conditions of the wet grinding process were established: operation time of 20 minutes, rotor speed of 4,000 rpm, bead size of 0.4 mm, feed rate of 40 mL/min and 30% mixing ration with water. The size of the resulting ultra fine calcium particles ranged between 40 and 660 mm.