• 제목/요약/키워드: Water Depth

검색결과 4,711건 처리시간 0.031초

원형관에서 상대수심을 고려한 점변류 해석 (Analysis of Gradually Varied Flow Considering Relative Depth in Circular Pipe)

  • 김민환;박정희;송창수
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.287-294
    • /
    • 2007
  • When we use the circular pipes for wastewater and storm water, we should be known the characteristics of the flow for accurate design. To elevate the design accuracy, we want to know the profile of flow. The roughness coefficient in the Manning equation is constant, but in actuality changed with the relative depth in circular pipe. This study was conducted to calculate the relative normal depth in changing the roughness coefficient (named relative roughness coefficient) with the relative depth in the analysis of gradually varied flow in the circular pipe by Newton-Raphson method. We performed the analysis of gradually varied flow using the relative normal depth and the relative roughness coefficient. We presented the 12 flow profiles with the relative depth and the relative roughness coefficient in circular pipe. The flow classification considering relative depth in circular pipe is available to analyse gradually varied flow profiles.

논 담수심 처리에 따른 관개용수량의 분석 (Analysis of water balance for pending depth treatment in paddy fields)

  • 박기중;정상옥;손성호
    • 한국농공학회논문집
    • /
    • 제46권4호
    • /
    • pp.13-21
    • /
    • 2004
  • The purpose of this study was to investigate tile effects of pending depth treatment on water balance in paddy fields. Field experiment was performed in an experimental farm in Taegu, southern part of Korea during the rice growing season In 2001, 2002 and 2003. Experimental plots were three 8m ${\times}$ 80m rectangular plots. Three pending depth treatments, very shallow, shallow, and deep were used. Daily values of water balance components were measured in the field. The irrigation amounts measured at the experimental plots showed that the very shallow and the shallow ponded plots required smaller amount than the deep ponded plot. The shallow ponded plot saved irrigation water about 17.7% compared with the traditional deep ponded plot in 2001 The very shallow ponded plot saved irrigation water about 25.7% compared with the traditional deep ponded Plot in 2002, The shallow ponded plot saved irrigation water about 18% compared with the deep ponded plot in 2003.

알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험 (Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator)

  • 김내현;신태룡;심용섭
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.

수심에 따른 줄(Zizania latifolia) 개체군의 경엽무 생장 비교 (Comparison of Shoot Growth in the Populations of Zizanis latifolia along Water Depth)

  • 조강현;김준호
    • The Korean Journal of Ecology
    • /
    • 제17권1호
    • /
    • pp.59-67
    • /
    • 1994
  • 팔당호 연안대에서 수심에 따른 줄(Zizania latifolia) 개체군의 저토 환경, 경엽부의 밀도, 높이 및 현존량을 조사하였다. 저토의 pH, 유기물함량, 총질소량, 유호태 인량 및 치환성 칼륨량은 수심에 따른 유의한 차이가 없었으나, 모래 함량은 수심이 깊을수록 적었다. 줄 경엽부의 밀도는 수심이 깊을수록 경엽부의 키가 높았고 경엽무 하나의 건물량과 단위면적당 현존량이 많았다. 경엽무 높이의 빈도분포는 줄이 생장함에 따라서 J자형과 첨두형으로 변하였으며, 높이의 불균등도는 감소하였는데, 그 변화는 수심이 깊은 곳에서 보다 빨리 일어났다. 따라서 줄은 수심이 깊을수록 경엽부의 밀도가 낮아지고, 그 높이와 현존량이 증가하여 수면 위로 경엽부를 돌출시키는 생장전략을 가지는 것으로 해석된다.

  • PDF

수심과 퇴적 깊이 변화에 따른 해저배관의 하중지지능력 평가 (Load-Bearing Capacity of Subsea Pipeline with Variation of Sea Water Depth and Buried Depth)

  • 백종현;김영표;김우식
    • 대한기계학회논문집A
    • /
    • 제36권10호
    • /
    • pp.1131-1137
    • /
    • 2012
  • 해저배관은 부력과 외부 충격을 방지하기 위하여 1.2~4m의 매설 깊이로 설치되어 운영된다. 해저배관은 수압과 토하중에 의한 외압으로부터 소성붕괴에 대한 저항성을 가져야한다. 해저배관에 수압과 토하중으로 발생하는 원주응력을 유한요소해석으로 파악하여 배관의 건전성에 미치는 영향을 평가하였다. 내압은 외압에 의한 소성붕괴 저항성을 향상시켜 소성붕괴 발생 깊이를 증가시켰다 동일 수심에서는 매설 깊이 증가에 따라 원주응력은 증가하나, 동일 매설 깊이에서는 수심이 증가함에 따라 배관에서 발생하는 원주응력은 감소한다.

Influence of Water Depth on Microalgal Production, Biomass Harvest, and Energy Consumption in High Rate Algal Pond Using Municipal Wastewater

  • Kim, Byung-Hyuk;Choi, Jong-Eun;Cho, Kichul;Kang, Zion;Ramanan, Rishiram;Moon, Doo-Gyung;Kim, Hee-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권4호
    • /
    • pp.630-637
    • /
    • 2018
  • The high rate algal ponds (HRAP) powered and mixed by a paddlewheel have been widely used for over 50 years to culture microalgae for the production of various products. Since light incidence is limited to the surface, water depth can affect microalgal growth in HRAP. To investigate the effect of water depth on microalgal growth, a mixed microalgal culture constituting three major strains of microalgae including Chlorella sp., Scenedesmus sp., and Stigeoclonium sp. (CSS), was grown at different water depths (20, 30, and 40 cm) in the HRAP, respectively. The HRAP with 20cm of water depth had about 38% higher biomass productivity per unit area ($6.16{\pm}0.33g{\cdot}m^{-2}{\cdot}d^{-1}$) and required lower nutrients and energy consumption than the other water depths. Specifically, the algal biomass of HRAP under 20cm of water depth had higher settleability through larger floc size (83.6% settleability within 5 min). These results indicate that water depth can affect the harvesting process as well as cultivation of microalgae. Therefore, we conclude that water depth is an important parameter in HRAP design for mass cultivation of microalgae.

취수 수심이 합천호의 수온성층과 방류 수온에 미치는 영향 모델링 (Modeling the Effect of Intake Depth on the Thermal Stratification and Outflow Water Temperature of Hapcheon Reservoir)

  • 정선아;김혜지;이혜숙
    • 환경영향평가
    • /
    • 제32권6호
    • /
    • pp.473-487
    • /
    • 2023
  • 1970~1980년대 준공된 우리나라의 다목적댐 저수지에는 발전방류를 위한 고정식 취수구가 심층에 설치되어 있어 일부 댐 하류에서는 냉수 방류에 의한 농작물 냉해, 안개 일수 증가 등의 문제점이 제기된 바 있다. 본 연구에서는 고정식 취수구를 통해 심층 취수가 이루어지고 있는 합천호를 대상으로 취수 수심이 저수지의 수온 성층 구조와 방류 수온에 미치는 영향을 분석하였다. 3차원 수리수질모형인 AEM3D를 이용하여 합천호의 연직 수온 분포를 재현하고 계절별 수온성층 구조를 분석하였으며, 수문 조건에 따른 수온성층 변화를 비교 분석하기 위하여 풍수해와 갈수해를 대상으로 모델링 하였다. 또한 취수심 변경 시나리오를 적용함으로써 취수 수심이 수온성층 구조에 미치는 영향을 분석하였다. 모의 결과 심층 취수를 표층 취수로 변경할 경우 수온약층의 형성 위치가 풍수해 6.5 m, 갈수해 6.8 m 감소하여 더 얕은 수심에 형성될 것으로 분석되었다. 또한 수체 안정도 지수인 Schmidt Stability Index (SSI)와 Buoyancy frequency (N2)가 증가하여 수온성층 강도가 증가하는 것으로 나타났다. 표층 취수시 연평균 방류수온이 풍수해 3.5℃, 갈수해 5.0℃ 증가하여 하류하천의 영향은 감소하나, 호내의 저수온층 수체적과 수온성층 강도가 증가하므로 추후 수질관리를 위해 취수심을 댐 운영의 주요인자로 고려해야 할 것으로 판단된다.

과기능적 음성장애 환자의 물저항발성: 튜브 직경과 물 깊이가 물거품 높이 및 최대발성지속시간에 미치는 영향 (Tube phonation in water for patients with hyperfunctional voice disorders: The effect of tube diameter and water immersion depth on bubble height and maximum phonation time)

  • 김민경;최성희;윤종인
    • 말소리와 음성과학
    • /
    • 제15권2호
    • /
    • pp.31-40
    • /
    • 2023
  • 목적: 물 속에서 튜브 발성은 semi-occluded vocal tract(SOVT) 연습 중 하나로 환자가 튜브를 물 속에 잠기게 하여 거품을 내면서 발성을 하는 것으로 음성 훈련에 널리 사용되어 왔다. 본 연구는 과기능성 음성장애 환자를 대상으로 물저항발성 동안 튜브 직경과 튜브를 담그는 물 깊이가 물거품 높이와 최대발성지속시간(maximum phonation time, MPT)에 미치는 영향을 조사하는 것을 목적으로 한다. 방법: 과기능성 음성장애 환자 17명에게 튜브 직경(5, 7, 10 mm), 튜브를 담그는 물 깊이(4, 7, 10 cm)에 따라 지속적인 /u/발성을 하면서 거품을 내도록 하였다. 물거품 높이 및 MPT 기록을 위해 수위 센서를 이용한 물저항발성 바이오피드백 시스템을 사용하였다. 결과: 물거품 높이는 튜브 직경에 의해 유의하게 변화한 반면 MPT는 튜브 직경과 깊이에 따라 유의하게 변화하였다. 직경이 더 넓을수록 주어진 깊이에 대해 유의하게 낮은 물거품 높이를 나타냈지만, 상대적으로 일관된 버블 높이가 유지되었다. 물의 깊이에 따라 주어진 튜브 직경에서 물거품 높이는 유의한 차이가 없었으나, 물의 깊이에 따라 MPT는 유의하게 감소하였고 튜브가 넓을수록 MPT가 유의하게 감소하였다. 결론: 수위 센서 방식의 물저항 바이오피드백 시스템은 튜브 직경 및 수심에 따른 기포 특성 및 성대 진동에 대해 유용한 정보를 제공하였다. 또한, 수위센서를 이용한 물저항발성 바이오시스템은 과기능적 음성장애가 있는 환자의 물저항 발성 중 호흡 지지를 모니터링하는 데 유용하게 사용될 수 있다.

선택취수 수심에 따른 취수탑 유입유동 특성 (Inflow Patterns Around a Water Intake Tower for Selective Withdrawal Depth)

  • 조용;김용열
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.63-70
    • /
    • 2010
  • Shallow water withdrawal systems have been replaced with a selected withdrawal system to keep stable raw water quality in spite of occurrence of algae and muddy inflow. Before reconstruction of the water intake tower in Yongdam reservoir supplying water to Gosan water treatment facility, we have predicted flow patterns of inflowing water into the water intake tower for various withdrawal conditions. It has been predicted that the water in the withdrawal layer is significantly inflowed from the front with fast velocity into the water intake tower irrespective of withdrawal depth, while the water away from the withdrawal layer is withdrawed a little from the side with slow velocity.

삼각형 래버린스 위어의 수심유지 효과 (Effect on Maintenance of Vertical Profile of Stream for Triangle-Type Labyrinth Weir)

  • 이승오;김영호;임장혁
    • 한국방재학회 논문집
    • /
    • 제9권3호
    • /
    • pp.107-115
    • /
    • 2009
  • 일반적으로 래버린스 위어는 월류부의 평면형상을 변화시켜 월류 길이를 증가시킨 위어이다. 래버린스 위어는 월류량 증대 및 수심유지에 활용될 수 있으며, 수질개선에도 효과가 있다. 그러나 수공구조물로써 기능 및 설계조건을 고려할 수 있는 수심유지 효과에 관한 연구는 상대적으로 부족한 실정이다. 본 연구의 목적은 삼각형 래버린스 위어의 수심유지효과 범위를 제시하여 보다 효율적인 삼각형 래버린스 위어 설계가 가능토록 하는데 있다. 또한, 수심유지 효과는 수리모형실험 및 3차원 수치모형인 FLOW-3D를 이용하여 분석하였다. 이러한 결과, 본 연구에서는 삼각형 래버린스 위어는 시점부까지 전 범위에서 수심유지효과가 나타났으며, 위어 종점부까지 수심이 유지되는 범위($H_t/P=0.08\sim0.27$)를 정량적으로 제시하여 효율적인 설계가 가능하도록 하였다.