• 제목/요약/키워드: Water Cycle

검색결과 2,172건 처리시간 0.026초

Overexpression of the Small Heat Shock Protein, PtsHSP19.3 from Marine Red Algae, Pyropia tenera (Bangiales, Rhodophyta) Enhances Abiotic Stress Tolerance in Chlamydomonas

  • Jin, Yujin;Yang, Sungwhan;Im, Sungoh;Jeong, Won-Joong;Park, EunJeong;Choi, Dong-Woog
    • Journal of Plant Biotechnology
    • /
    • 제44권3호
    • /
    • pp.287-295
    • /
    • 2017
  • Water temperature is one of the major factors that impacts the growth and life cycle of Pyropia tenera, one of the most valuable and cultivated marine red algae belonging to Bangiales (Rhodophytes). We analyzed transcriptome from gametophyte of P. tenera under normal and high temperature conditions, and identified four small heat shock proteins (sHSPs). They have no significant amino acid sequence homology with known proteins in public databases except PhsHSP22 from Pyropia haitanensis. PtsHSP19.3 gene responded to high temperature but slightly or not to desiccation, freezing or high salt condition. When the PtsHSP19.3 gene was overexpressed in Chlamydomonas reinhardtii, transformed Chlamydomonas lines revealed much higher growth rate than that of control cells under heat stress condition. Transformed cells also grew well in those of the control cell onto the medium containing high salt or $H_2O_2$. When the PtsHSP19.3 was fused to GFP and introduced into tobacco protoplast, fluorescence was detected at several spots. Results indicate that PtsHSP19.3 may form super-molecular assembles and be involved in tolerance to heat stress.

Roles of Ascospores and Arthroconidia of Xylogone ganodermophthora in Development of Yellow Rot in Cultivated Mushroom, Ganoderma lucidum

  • Kang, Hyo-Jung;Chang, Who-Bong;Yun, Sung-Hwan;Lee, Yin-Won
    • The Plant Pathology Journal
    • /
    • 제27권2호
    • /
    • pp.138-147
    • /
    • 2011
  • Xylogone ganodermophthora, an ascomycetous fungus, is known to cause yellow rot in the cultivated mushroom Ganoderma lucidum. In this study, we investigated the dissemination of this fungal pathogen in G. lucidum grown in cultivation houses. To determine the role of ascospores produced by X. ganodermophthora in disease development, we constructed a green fluorescent protein-labeled transgenic strain. This X. ganodermophthora strain produced a number of ascomata in the tissues of oak logs on which G. lucidum had been grown and on the mushroom fruit bodies. However, the ascospores released from the ascomata were not able to germinate on water agar or potato dextrose agar. Moreover, less than 0.1% of the ascospores showed green fluorescence, indicating that most ascospores of X. ganodermophthora were not viable. To determine the manner in which X. ganodermophthora disseminates, diseased oak logs were either buried in isolated soil beds as soil-borne inocula or placed around soil beds as air-borne inocula. In addition, culture bottles in which G. lucidum mycelia had been grown were placed on each floor of a five-floor shelf near X. ganodermophthora inocula. One year after cultivation, yellow rot occurred in almost all of the oak logs in the soil beds, including those in beds without soil-borne inocula. In contrast, none of the G. lucidum in the culture bottles was infected, suggesting that dissemination of X. ganodermophthora can occur via the cultivation soil.

원자력 구조재 신뢰성 향상을 위한 열피로 균열 시험편 제작 기법 개발 (Development the Technique for Fabrication of the Thermal Fatigue Crack to Enhance the Reliability of Structural Component in NPPs)

  • 김용;김재성;이보영
    • Journal of Welding and Joining
    • /
    • 제26권2호
    • /
    • pp.43-49
    • /
    • 2008
  • Fatigue cracks due to thermal stratification or corrosion in pipelines of nuclear power plants can cause serious problems on reactor cooling system. Therefore, the development of an integrated technology including fabrication of standard specimens and their practical usage is needed to enhance the reliability of nondestructive testing. The test material was austenitic STS 304, which is used as pipelines in the Reactor Coolant System of a nuclear power plants. The best condition for fabrication of thermal fatigue cracks at the notch plate was selected using the thermal stress analysis of ANSYS. The specimen was installed from the tensile tester and underwent continuos tension loads of 51,000N. Then, after the specimen was heated to $450^{\circ}C$ for 1 minute using HF induction heater, it was cooled to $20^{\circ}C$ in 1 minute using a mixture of dry ice and water. The initial crack was generated at 17,000 cycles, 560 hours later (1cycle/2min.) and the depth of the thermal fatigue crack reached about 40% of the thickness of the specimen at 22,000 cycles. As a results of optical microscope and SEM analysis, it is confirmed that fabricated thermal fatigue cracks have the same characteristics as real fatigue cracks in nuclear power plants. The crack shape and size were identified.

Phenol-Formaldehyde (PF) Resin Bonded Medium Density Fiberboard

  • Park, Byung-Dae;Riedl, Bernard;Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권1호
    • /
    • pp.64-71
    • /
    • 1999
  • 본 연구는 통상적으로 충밀도 섬유판 제조에 사용되고있는 요소수지를 페놀수지로 대체함으로써 그 장단점을 찾아 보기 위해 실행되었다. 페놀수지을 이용해 제조한 중밀도 섬유판의 성능은 표준 요건을 충족시켰으며 높은 내구성을 보였다. 아울러 24 시간 냉수 침적후 두께팽창은 2 퍼센트 이하로 낮게 나타났다. 요소수지를 페놀수지로 대체했을 경우 단점들은 비교적 높은 수지함량 (8% 섬유전건종량기준)과 긴 열압시간 (7 분)으로 판명되었다. 이러한 결과들은 페놀수지을 사용한 중밀도 섬유판제조시 열압공정의 최적화가 되어야함을 시사하였다.

  • PDF

PCM 함유된 축열석고보드의 열환경특성 (Thermal Environment Characteristic of the Heat Storage Gypsum Board Included with Phase Change Material)

  • 권오훈;윤희관;한성국;안대현;심명진;조성운;박종순;김재용
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.570-574
    • /
    • 2010
  • 기존 단열재의 주된 기능은 단지 열전달을 차단하는 기능과 건물로부터 열손실을 줄여주는 기능만을 수행했다. 반면, 축열재는 특정온도 범위 내에서 열에너지를 저장 또는 방출함으로써 건물에너지 사용량을 절감할 수 있다. 축열 건자재는 실내 공기온도 변화주기를 효과적으로 조절하여 일정하게 온도를 유지시킬 수 있다. 결과적으로 냉난방시스템 기능을 효율적으로 향상시킬 수 있다. 본 연구는 건축자재로 많이 이용되고 있는 석고보드에 상변화잠열물질을 축열재로 첨가하여 그 물성과 열환경 특성을 파악하였다. 또한 축열 건자재를 활용할 때 발생가능한 문제점을 확인하였다. 마지막으로 TVOC와 HCHO 함량 분석으로부터 오염물질의 배출가능성을 조사하여 축열 건자재의 환경 친화도를 검토하였다.

대두유 첨가 도정 쌀의 특성 및 저장성에 관한 연구 (Studies on the Qualities and Storability of Soybean Oil-Added Milled Rice)

  • 이병영;김영배;손종록;윤인화;한판주;민용규
    • 한국식품과학회지
    • /
    • 제23권2호
    • /
    • pp.248-250
    • /
    • 1991
  • 대두유 첨가 도정쌀의 품질과 저장성을 규명하기 위하여 현백과정 중 도정이 거의 완료된 마지막 순환 도정단계에 대두유를 0.07 및 0.10% 첨가 도정하여 생산된 쌀에 대한 지방함량, 취반특성, 외관(색) 및 저장성을 조사하였다. 대두유 첨가 도정쌀의 지방함량은 무첨가가 0.65%인데 비하여 첨가 도정쌀은 $0.70{\sim}0.72%$였으며, 취반특성 즉 가열흡수율, 팽창용적, 용출고형물 및 요오드 정색도는 첨가 도정쌀이 무첨가 도정쌀 보다 낮았다. 그리고 색 즉 Hunter L, a, b값 및 백도는 무첨가 도정쌀에 비해 첨가 도정쌀이 낮아 ${\Delta}E$값이 높았다. 대두유 첨가 도정쌀의 저장 중 지방산도는 증가하였으나 첨가 및 무첨가 간에 큰 차가 없었다.

  • PDF

금속 시편 형태에 따른 PEC 초음파 제염 성능 (PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens)

  • 원휘준;김계남;정종헌;박진호;오원진
    • 방사성폐기물학회지
    • /
    • 제3권4호
    • /
    • pp.293-300
    • /
    • 2005
  • Type 304 stainless steel 시편에 느슨하게 붙어있는 $Eu_2O_3$ 분말에 대한 초음파 제염 거동을 조사하였다. 매질을 물, PFC 및 $0.1\;vol\%$의 음이온 계면활성제를 함유한 PFC 용액으로 변화시킴에 따라 제염계수는 20, 50 및 200으로 증가하였다. 제염계수에 차이가 생기는 이유를 초음파 매질의 표면장력 및 양으로 하전된 산화물 표면과 음이온 계면활성제 사이의 상호작용에 기인한 것으로 설명할 수 있었다. 음이온 계면활성제를 함유한 PFC 용액 내에서 $Eu_2O_3$ 분말로 오염된 평면 시편, 파이프 시편, 틈새 시편 및 용접 시편에 대한 초음파 제염 효과를 관찰하였다. 연구된 모든 시편에 대해, 대부분의 오염물이 완벽하게 제거되는 것으로 나타났다. 길이가 6cm인 파이프 시편에 대해서는 오염물의 $98.5\%$가 제거되었다.

  • PDF

비모수통계방법을 이용한 원자력발전소 작업자 반복성 고피폭작업 도출 (Use of Non-Parametric Statistical Method in Identifying Repetitive High Dose Jobs in a Nuclear Power Plant)

  • Young-Ho Cho;Young-Hoi Herr
    • 방사성폐기물학회지
    • /
    • 제2권1호
    • /
    • pp.41-51
    • /
    • 2004
  • 원전 작업자 방사선량의 효과적인 저감을 위해서는 발전소 내에 축적된 작업자 피폭선량자료들을 분석하는 것이 반드시 필요하다. 자료의 분석을 통해, 발전소에서 수행되는 방사선작업들 중 반복적으로 고피폭을 유발하는 작업들을 파악하는 것이 필요하며, 본 연구에서는 이러한 반복성고피폭작업들을 도출하기 위한 방법론으로 백분위수 순위합 방법을 제안한다. 이는 비모수통계학 이론에 근거한 방법론으로, 본 연구에서는 이 방법을 이용하여 고리 3,4 호기 작업자 피폭선량 자료를 분석, 고피폭작업들을 도출하였다. 도출 결과는 통계적으로 검증되며, 그 결과 백분위수 순위합 방법의 효과 및 타당성을 입증하였다.

  • PDF

CRUDTRAN을 이용한 국내 PWR 1차계통내 부식생성물 거동예측에 관한 연구 (A Study on Corrosion Product Behavior Prediction for Domestic PWR Primary System by using CRUDTRAN)

  • 송종순;윤태빈;이상헌
    • 방사성폐기물학회지
    • /
    • 제13권4호
    • /
    • pp.253-262
    • /
    • 2015
  • 원자력 발전소 내 외부 계통의 표면에 침적된 방사성핵종은 원자로 구조재 및 핵분열생성물의 부식생성물 활성화에 의해 생성된다. 특히, 1차계통 내부에서 물과 부식된 표면 사이의 지속적인 마찰은 냉각재와 부식생성물을 혼합하게 만든다. 그리고 이것들은 계통을 따라 순환한다. 본 논문에서는 설계단계에서 사용되는 1차 계통의 부식생성물과 방사성 핵종의 양을 예측하는 CRUDTRAN, DISER, MIGA-RT 및 CPAIR 코드를 분석하였다. 또한, CRUDTRAN을 이용하여 국내 경수로 1차계통내 부식생성물 거동을 예측하였다. 본 연구목적은 웨스팅하우스형 원전의 실제 데이터로 계산된 값을 측정값과 비교하여 부식생성물 평가 모델의 신뢰도를 향상시키는데 있다.

사용후핵연료 습식저장 시설의 중대사고 안전성 검토 (Safety Review of Severe Accident Senario for Wet Spent Fuel Storage Facility)

  • 신태명
    • 방사성폐기물학회지
    • /
    • 제9권4호
    • /
    • pp.231-236
    • /
    • 2011
  • 지난 2011년 3월의 후쿠시마 원전 사고시 원자로 건물에서의 연쇄적인 수소폭발이 발생하였을 때 관계자들은 제1원전 4호기의 폭발에 더욱 놀랐었는데 이는 그 당시 4호기는 정기보수를 위하여 원자로내 모든 핵연료를 저장조에 보관중이었기 때문이다. 저장조내 냉각수 유실로 노심에서 옮겨진 핵연료가 공기 중에 노출되어 수소가 발생하고 임계가 도달하였다면 더욱 심각할 수도 있기 때문이었는데 다행히 추후에 양호한 냉각수 상태가 확인되어 우려할 상황을 피할 수 있었다. 본 논문에서는 후쿠시마 원전 사고를 계기로 국내 원자력 발전소내 핵연료 임시 저장시설의 안전성과 관련하여 중대사고 관점에서 검토해 보고자 한다.