• Title/Summary/Keyword: Water Characteristics

Search Result 17,662, Processing Time 0.046 seconds

A Study on Moisture Related Properties and Human Sensations of Underwear (1) -A Study on Water and Water Vapor Transport characteristics of Underwear Fabrics- (시판 내의류소재의 수분특성 및 착용감에 관한 연구 (I) -시판 내의류 소재의 수분특성-)

  • 이순원
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.4
    • /
    • pp.1-13
    • /
    • 1988
  • The purpose of this study is to investigate water and after vapor transport characteristics of underwear fabrics. Experimental materials were cotton woven fabric and cotton knitted fabric, nylon tricot (untreated and hydrophilic finished) and cotton/polyester/cotton triple layer. Cotton knitted fabric have three types of knit structure (interlock, rib, plain stitch) and knit with either 38's or 60's combed yarn. And cotton woven fabric have plain weave with 60's combed yarn. As experimental methods, vapor cup test, dynamic method, vertical wicking test and transplanar uptake test were used. The results are as follows. 1) In cotton specimens, the order of water vapor transpiration (wvt) was plain > rib > interlock in the same yarn diameter. The knit fabric of thinner yarn showed the better wvt among the same knit structure. 2) In cotton specimens, the order of water absorbency was interlock > rib > plain in the same yarn diameter. the knit fabric of thicker yarn showed the better absorbency among the same knit structure. 3) When knit fabric (60's plain) is compared with woven fabric 960's plain), knit fabric showed faster rate of wvt, more amount of uptake and slower rate of water uptake than woven fabric did. 4) When compared untreated nylon with hydrophilic finished nylon, hydrophilic finished nylon showed much more water absorbency than untreated nylon did, but showed same rate of wvt. 5) The water transport characteristics of triple layer underwear fabric showed that the thinner and the lighter one, the better wvt and absorbency did.

  • PDF

Dynamic Model of Water Electrolysis for Prediction of Dynamic Characteristics of Cooling System (냉각계통 동적 예측을 위한 수전해 시스템 동적 모사 모델)

  • YUN, SANGHYUN;YUN, JINYON;HWANG, GUNYONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Water electrolysis technology, which generates hydrogen using renewable energy resources, has recently attracted great attention. Especially, the polymer electrolyte membrane water electrolysis system has several advantages over other water electrolysis technologies, such as high efficiency, low operating temperature, and optimal operating point. Since research that analyzes performance characteristics using test bench have high cost and long test time, however, model based approach is very important. Therefore, in this study, a system model for water electrolysis dynamics of a polymer electrolyte membrane was developed based on MATLAB/Simulink®. The water electrolysis system developed in this study can take into account the heat and mass transfer characteristics in the cell with the load variation. In particular, the performance of the system according to the stack temperature control can be analyzed and evaluated. As a result, the developed water electrolysis system can analyze water pump dynamics and hydrogen generation according to temperature dynamics by reflecting the dynamics of temperature.

Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems (수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안)

  • Seo, Dae-Keun;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Varietal Difference in Water Absorption Characteristics of Milled Rice, and Its Relation to the Other Grain Quality Components

  • Hae Chune, Choi;Jeong Hyun, Chi;Soo Yeon, Cho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • Nineteen japonica and Tongil-type rices were selected from seventy nine Korean and Japanese rice cultivars grown in 1989 based on the water uptake behavior of milled rice under the room temperature and boiling conditions. The selected rice cultivars were investigated for water absorbability and some physicochemical characteristics of milled rice, proper water amount for cooking and sensory evaluation of cooked rice. The relationships among the tested grain properties were also examined. The highest varietal variation of water uptake rate was observed at twenty minutes after soaking in water. The maximum water uptake of milled rices at room temperature occurred mostly at about eighty minutes after soaking in water. Newly harvested rices showed a significantly lower water uptake rate of milled rice at 20 minutes after soaking, a relatively higher maximum water absorption ratio under the room temperature, and the less water uptake and volume expansion of boiled rice compared with the one-year old rice samples. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice ansd the palatability of cooked rice. The water/rice ratio(in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was averaged to 2.63(in v/v basis). The water amount needed for optimum cooking was the lowest in Cheongcheongbyeo (Tongil-type rice) and the highest in Jinbubyeo, and the amount could be estimated with about 70% fittness by the multiple regression formula based on some water uptake characteristics, ADV and amylose content of milled rice as the independent variables. Nineteen rice cultivars were classified into seven groups based on scatter diagram projected by principal component analysis using eight properties related to water uptake and gelatinization of milled rice.

  • PDF

Establishment of Landfill Site Preliminary Assessment Model Based on Contamination Characteristics of Water Resources (수자원(水資源) 오염 특성에 의한 불량매립지(不良埋立地) 예비평가모형(豫備評價模型) 정립)

  • Hong, Sang-Pyo;Kim, Jung-Wuk
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 1995
  • To assess preliminarily the contamination potential of water resources including groundwater owing to the hydrogeological characteristics of landfill site and the potential impact to humans and animals through contamination of water resources by leachate, "Landfill Site Preliminary Assessment Model(LASPAS)" was contrived. LASPAS could help them proritization of remediation of landfil sites by the convenient and relatively simple evaluation method of landfill site features. LASPAS was designd to aliot numerical ratings to landfill site related factors undermentioned; 1) hydrogeological factors such as hydraulic conductivity of aquifer, thickness of confining layer over aquifer, topographical slope, net recharge, and subsurface containment 2) water resources contamination factors of impacts on receptors such as proximity to drinking water supply, substitutability of drinking water supply, type of use of water resources, known impact on drinking water supply, and flood potential.

  • PDF

Observation of local water content and current density in the PEMFC system (고분자 전해질 연료전지의 전류밀도와 국소 함수량 관찰)

  • Ko, Dong-Soo;Moon, Cheor-Ron;Choi, Gyung-Min;Kim, Duck-Jool;Jung, Ji-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.69-72
    • /
    • 2008
  • The local water contents and water transfer characteristics in the PEMFC system were investigated by numerical simulations and experiments. The performance of a lab-scale PEMFC is measured for fully humidified gases conditions and non-humidified ones. In order to observe the local water contents and water transfer characteristics inside PEMFC, the numerical simulation using CFD module on STAR-CD(es-pemfc) were conducted. The results show that the water content was increased as increasing current density, whereas it was decreased in high current density region. Then there was close correlation between high water content and internal temperature inside of MEA, and high current density was observed when internal temperature was dramatically increased.

  • PDF

Comparison of water quality of domestic natural mineral water (국내 먹는샘물의 수질특성비교)

  • Doo, Yong-Kyoon;Kim, Jun-Hwan;Kim, Chang-Su;Chang, Duk
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.88-94
    • /
    • 2000
  • The purpose of this study was to analyze and compare the contents of minerals and ionic components in domestic commercial natural mineral waters, and to investigate the relationship between water quality and characteristics of suspended and rocks there of its source. All mineral waters tested in this study met the korean mineral water quality guideline, although chemical components varied widely depending upon the geological characteristics and degree of urbanization of the source area or physical water treatment method. The water quality of commercial bottled water was different from that of source water, especially in cationic components, and showed a tendency to become worse with time elapsed. The water quality on the bottle was also different from the measured quality.

  • PDF

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

Relationship between rural watershed characteristics and stream water quality (농촌유역특성과 하천수질과의 관계)

  • 홍성구;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.3
    • /
    • pp.56-65
    • /
    • 2001
  • In interpreting stream water quality data, scientific or statistical mehtods should be employed. Classical parametric statistical methods may not be adopted in analyzing water quality data, due to the violation of normality. In this study, nonparametric statistical methods, such as Kruskal-Wallis test and Mann-Whitney test, were used in comparing water quality data from several monitoring stations. Water quality data used are those collected Bokha watershed, located in Ichon-city, Kyonggi province. Based on the test results, domestic sewage is the major pollution source. A couple of sub-watersheds with a large number of livestock do not show significant differences in water quality parameters. It should be noted that comparison of mean values of water quality parameters is difficult to relate water quality with watershed characteristics. The results also indicate that livestock farming does not significantly affect the water quality.

  • PDF

Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil (체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성)

  • Son, Young-Hwan;Bong, Tae-Ho;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.5
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.