• Title/Summary/Keyword: Wastewater treatment system

Search Result 998, Processing Time 0.024 seconds

Removal and Decomposition of Impurities in Wastewater From the HyBRID Decontamination Process of the Primary System in a Nuclear Power Plant (원전 일차계통 HyBRID 제염공정 발생 폐액 내 불순물 제거 및 분해)

  • Eun, Hee-Chul;Jung, Jun-Young;Park, Sang-Yoon;Park, Jeong-Sun;Chang, Na-On;Won, Hui-Jun;Sim, Ji-Hyoung;Kim, Seon-Byeong;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.429-435
    • /
    • 2019
  • Decontamination wastewater generated from the HyBRID decontamination process of the primary system in a nuclear power plant contains impurities such as sulfate ions, metal ions containing radioactive nuclides, and hydrazine (carcinogenic agent). For this reason, it is necessary to develop a technology to remove these impurities from the wastewater to a safe level. In this study, it has been conducted to remove the impurities using a decontamination wastewater surrogate, and a treatment process of the HyBRID decontamination wastewater has been established. The performance and applicability of the treatment process have been verified through 1 L scale of replicates and a pilot scale (300 L/batch) test.

Seasonal Effects of Livestock Wastewater Treatment by a Constructed Wetland (인공습지에 의한 축산폐수의 처리시 계절적 영향)

  • Park, Jae-Hong;Kwon, Soo-Youl
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.33-39
    • /
    • 2005
  • Constructed wetlands are considered as an important tool for wastewater treatment, wastewater management and flooding control. In addition, one of the most promising technologies for application in many countries seems to be constructed wetlands due to their properties such as utilization of natural processes, simple construction, operation and maintenance, process stability, cost effectiveness, etc. This research is performed to find the possibility for treating livestock wastewater using a constructed wetland. The removal efficiencies of CODcr, TN, TP, SS, and color were 97.9%, 97.8%, 97.2%, 99.1%, and 84.9%, respectively. In particular, SS was completely removed. In conclusion, constructed wetlands could be applied to livestock wastewater treatment. Further, it needs time for stabilization to reduce the pollutants accumulated in soil.

  • PDF

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.

Quantification of Bacillus Species in a Wastewater Treatment System by the Molecular Analyses

  • Mori Koji;Iriye Ryozo;Hirata Mutsunori;Takamizawa Kazuhiro
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.482-489
    • /
    • 2004
  • Bacillus species were observed and quantified by molecular approaches, using the 16S rDNA primers/probes, in a wastewater treatment plant designed for the purpose of stimulating the growth of Bacillus species. The plant has been operating as a test plant since 1997 in the city of Ina, Japan, with excellent treatment performance. Observations by in situ hybridization, using Bacillus-specific probes, indicated that Bacillus strains were inhabited in the plant and their num­bers decreased during the treatment process. Similar results were obtained from a quantitative PCR analysis using a Bacillus-specific primer set, and the amount of DNA originating from various Bacillus species was maximally $1.91%\$ of the total DNA in the wastewater treatment tank. Clone library analysis using the Bacillus-specific primers suggested that, while the population was no­ticeably increased, the phylogenetic diversity of the increasing Bacillus species was very low.

Efficiency evaluation of MBR, A/O processes utilizing self-sufficient energy (에너지 자립형 MBR, A/O 공정의 효율 평가)

  • Lim, Setaek;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.305-314
    • /
    • 2014
  • A pilot plant (Q=5 $m^3/d$) study was implemented for small and medium sized personal wastewater treatment plant effluent to evaluate MBR and A/O processes utilizing self-sufficient energy composed of wind and solar energy. The removal efficiencies of BOD, SS, turbidity and color were sufficient for legal water quality standards for gray water. However, those of nitrogen and phosphorus could not meet legal regulations which suggested that further removal of those contaminants were needed for reuse of the treated water. Self-sufficient energy rate was 100 % for the pilot plant due to excessive design capacity. In this research, wind and solar energy system was applied considering geological characteristics, which significantly improved energy self-sufficiency. Substantial improvement on energy self-sufficiency can be obtained by optimized investment and operation at a full scale wastewater treatment plant.

Treatment of Fish Processing Wastewater Using Sequencing Batch Reactor (SBR) (연속회분식 반응기를 이용한 수산물 가공폐수 처리)

  • Paik, Byeong Cheon;Shin, Hang Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.18-26
    • /
    • 1994
  • This research investigated efficient operation mode for the successful performance of SBR(sequencing batch reactor) treating fish processing wastewater, and the effect of sodium chloride (NaCl) on treatment efficiency. 2-hour-annerobic, 6-hour-aerobic and 3-hour-anoxic operation during reaction period was found an effective operating method for organic and nitrogen removal from fish processing wastewater in SBR system. The average removal efficiencies of COD, BOD, and total nitrogen in SBR operated continuousely were 91%, 95%, and 67.1%, respectively. The estimated values of biomass yield coefficient(Y), microbial decay coefficient($K_d$), and bioreaction rate constant(K) were $0.35gMLSS/gCOD_{removed}$, $0.015day^{-1}$, and $0.209hr^{-1}$, respectively. As NaCl concentration increased from 5 to 30g/L, sludge settleability was cnhanced but organic removal in the reactor was decreased. NaCl of influent had considerable relationship with COD removal, whereas it did not significant affect nitrogen removal.

  • PDF

Treatment of Textile Wastewater by Anaerobic Sludge and Aerobic Fixed-Bed Biofilm Reactor (혐기성 슬러지 공정과 호기성 고정생물막 공정을 이용한 염색폐수 처리)

  • 박영식;문정현
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.55-63
    • /
    • 2002
  • This study was carried out to treat textile wastewater using anaerobic sludge and aerobic fixed-bed biofilm reactor immobilized with Bacillus sp. dominated activated sludge(Bacillus sp. fraction : 81.5%). The range of influent con-centration of SCOD and soluble color were 1032-1507 mg/1, and 1239-1854 degree, respectively. Continuous treatment experiments were performed with variation of textile wastewater ratio at a same HRT. When textile wastewater ratio was 100%(HRT : 24 hours), The removal efficiency of SCOD and soluble color were 88% and 78%, respectively. When compare aerobic reactor of this study that was immobilized with Bacillus sp. dominated activated sludge to other study that was immobilized with activated sludge, SCOD and soluble color removal efficiency of this study showed a little higher efficiency than immobilized with activated sludge. The Bacillus sp. fraction of initial condition was 81.5%), but the fraction after operation was decreased to 31.8%).

A study about treatment for water treatment residual sludge using submerged membrane system (침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구)

  • Kim, Jun-Hyun;Lee, Ju-Hyung;Moon, Baek-Su;Kwak, Young-Ju;Jang, Jung Woo;Kim, Jinho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.181-193
    • /
    • 2014
  • Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

Application Study of small-scale sewage treatment system with A2/O precess in Mongolia (A2/O 공법을 이용한 소규모 하수처리시스템의 몽골 현지 적용에 관한 연구)

  • Yeo, Yeongki;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.431-440
    • /
    • 2017
  • The small-scale sewage treatement system with $A^2/O$ process was applied to evaluate applicability for Mongolian sewage, It was designed to have 10 m3/d flowrate and installed in Ulaanbaatar, Mongolia. During over 6month operation BOD, COD, TN, TP removal efficiency were measured and operation condition was optimized. In addition, MLSS concentration its internal circulation rate and DO were adjusted properly. BOD, COD showed average 88 perecent of removal and TN and TP achieved 81 percent and 88 percent removal efficency, respectively. Maxium influent concentration of BOD, COD, TN and TP was 214 mg/L, 300 mg/L, 24.3 mg/L and 5 mg/L respectively, which were decreased to 4.1 mg/L, 5.6 mg/L, 1.3 mg/L and 0.15 mg/L by the test system. This study show possibility tham small-scale sewage treatment system could be a useful system for scattered sewage wastewater treatment.

Suggestions for Cost Improvement of High concentration Linked Treatment in Municipal Wastewater Treatment Plant (하수처리장에서의 고농도 연계처리수에 대한 요금 개선 제안)

  • Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.92-99
    • /
    • 2020
  • Linked treatment refers to a system that relieves the burden of the business by linking high concentrations of wastewater such as human waste, manure, leachate, and other industrial wastewater to nearby municipal wastewater treatment plants(MWTPs). In 2018, 187 MWTPs, which are about 4.5% of the total domestic MWTPs, have implemented a linked treatment system, but local governments are having difficulties in operating sewage treatment due to lack of reasonable cost estimation standards. Therefore, we proposed an improvement plan to solve the problem in the calculation method that currently imposes linked wastewater. To this end, the effects and correlations of the linkage treatment system on the sewage treatment unit were analyzed, and among them, the main factors with the highest correlation were applied to the improvement plan. As a result, an improvement plan that improved three parts of the existing calculation method was presented, and the calculation method and the calculation case using the existing literature values were also presented. This can be used as a basis for future reference by local governments to implement linkage treatment, and to revise local sewerage ordinance and is believed to be helpful in operating a rational linkage system.