• Title/Summary/Keyword: Wastewater treatment process

Search Result 1,427, Processing Time 0.027 seconds

Diagnosis of Wastewater Treatment Processes through the Wastewater COD Fractionation and Process Simulation I : Wastewater COD Fractionation (유입하수 유기물 분류 및 공정모사를 통한 하수처리공정 진단 I : 유입하수 유기물 분류)

  • Choi, Young-Gyun;Chung, Tai-Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.513-520
    • /
    • 2007
  • The simulation programs used for diagnosis and design of activated sludge process require organic fractions in municipal wastewater as the input variables. However, methods for characterizing organic fractions are still under development, and are not standardized. In this study, total COD of municipal wastewater was experimentally subdivided into readily and slowly biodegradable COD as well as soluble and particulate inert COD. The COD fractionation of the three municipal wastewater for one year shows linear relationship between each COD fraction and TCOD concentration with around 100% COD balance. This result means that the COD fraction do not vary very much with time, although the actual influent concentrations vary significantly with time and day. Therefore, the experimentally subdivided COD fractions can be utilized as wastewater specific parameters for the simulation of activated sludge processes.

The Submerged Biofilm Process using Oyster-Shell Media for Wastewater Treatment and Prediction (굴패각을 담체로 사용한 침적고정 생물막공법 및 예측)

  • 문병현;이택순
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.671-678
    • /
    • 1997
  • This study was conducted to use oyster shell as media for biological wastewater treatment. The comparison between the removal efficiencies of the activated sludge and the submerged biofilm process with oyster shell media (5% of reactor volume) for domestic sewage treatment was made. The contaminant removal efficiencies of the submerged process were higher than that of the activated sludge process. And the removal efficiencies of the submerged biofilm process with oyster shell media of 10% and 18% were Investigated at various loading rate. The removal efficiencies of 10% were higher than that of the 18% during the experimental period. The effluent concentration from the sub- merged bloom process using oyster shell media was prediceted by the Stover-Kincannon model.

  • PDF

Estimation of Greenhouse Gas Emissions and Environmental Assessment of Dye Wastewater Treatment Process (염색폐수 처리공정의 온실가스 배출량 산정 및 환경성 평가)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1881-1888
    • /
    • 2014
  • Greenhouse gas (GHG) emissions from dye wastewater treatment processes were estimated by analysing their mass and energy balances, which were then used as baseline information for environmental assessment. The total GHG emissions from dye wastewater treatment plants were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The amounts of $CO_2$, $CH_4$ and $N_2O$ emissions were calculated according to the Intergovernmental Panel on Clime Change (IPCC) guideline for the GHG target management system. For 3 years between 2011 and 2013, direct and indirect emissions were on average 8,742.7 and 7,892.0 Ton.$CO_2eq/year$, respectively, with the former exhibiting 52.6 %. Also, compared to 2012, in 2013, the eco-efficiency indicator by the GHG emissions was found to be more than 1, suggesting that environmental quality was effectively improved.

Removal of textile dyes in wastewater using polyelectrolytes containing tetrazole groups

  • Caldera-Villalobos, Martin;Pelaez-Cid, Alejandra-Alicia;Martins-Alho, Miriam-Amelia;Herrera-Gonzalez, Ana-Maria
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2394-2402
    • /
    • 2018
  • Textile dyes are some of the pollutants which have received the most attention because of the large volume of wastewater generated by the textile industry. Removal by means of adsorption is one of the most versatile alternatives to treat these effluents. Even though different adsorbents such as activated carbons and mineral materials have been proposed, polymeric adsorbents are a viable alternative. This work reports for the first time the use of polyelectrolyte PTZ and macroelectrolyte MTZ containing tetrazole groups as adsorbents useful in the textile dyes removal present in aqueous solutions and wastewater. Because of the anionic character of the tetrazole group, MTZ exhibits selective adsorption capabilities for cationic dyes of up to $156.25mg{\cdot}g^{-1}$. The kinetic study of the process of adsorption shows that PTZ and MTZ fit a pseudo second-order model. MTZ also shows utility as a flocculant agent in the treatment of wastewater containing dyes Indigo Blue and Reactive Black. The results showed that PTZ and MTZ may be used in the treatment of wastewater in a process of coagulation-flocculation followed by the treatment by adsorption. This two-stage treatment removed up to 95% of the dye present in the wastewater. As well as removing the dyes, the values for COD, suspended solids, pH, and color of the wastewater decreased, thus significantly improving its quality.

Utility Estimation of Pre-filtration on the Membrane Water Treatment Process (막여과 정수처리공정에서 전여과공정의 효용성 평가)

  • Park, Min Koo;Choi, Sang il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.445-448
    • /
    • 2008
  • The application of the membrane filtration process has been increased for the drinking water treatment system because of excellent quality of treated water compared with the sand filtration process. The selection of suitable pre-treatment processes and optimum flux according to the characteristics of raw water are important factors for the design of membrane processes. In this study, the most efficient pre-treatment processes for drinking water was selected by investigating the effects of pre-treatment processes on the operational stability of the membrane filtration process. Both lab-scale and pilot-scale experiments were conducted. In the lab-scale test, the effect of pre-treatment processes on the stability of the membrane filtration process was investigated indirectly by comparing the performance of membrane flux for raw water, pre-treated water, and membrane permeated water. In the pilot-scale test, the usefulness of prefiltration processes was assessed by comparing the performance of single membrane process and hybrid coagulation-membrane process. The results indicated that the coagulation process contributed to the stabilization of trans-membrane pressure (TMP) by removing contaminants on membranes, though the pre-filtration process had little effect on the TMP.

Selection of coagulant using jar test and analytic hierarchy process: A case study of Mazandaran textile wastewater

  • Asadollahfardi, Gholamreza;Zangooei, Hossein;Motamedi, Vahid;Davoodi, Mostafa
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • Textile factories are one of the industries which its wastewater treatment is a challenging issue, especially in developing countries and a conventional treatment cannot treat all its pollutants properly. Using chemical coagulants is a technique for physical and chemical primary treatment of the wastewater. We applied jar test for selection of suitable coagulant among the five coagulants including alum, calcium hydroxide, ferrous sulfate, ferrous chloride and barium chloride for the effluent of wastewater in Mazandran textile factory located in Mazandran Province, Iran. In addition, jar test, we also used analytic hierarchy process (AHP) method considering criteria which included coagulation cost, sensitivity to pH change, the amount of sludge generation and side effects for coagulation. The results of the jar test indicated that calcium hydroxide was proper among the coagulants which it removed 92.9% total suspended solid (TSS), 70% dye and 30% chemical oxygen demand. The AHP analysis presented that calcium hydroxide is more suitable than other coagulants considering five criteria.

A Pilot Study on Air Flotation Processes for Retrofitting of Conventional Wastewater Treatment Facilities (하수처리시설의 Retrofitting을 위한 파일럿 규모 공기부상공정 연구)

  • Park, Chanhyuk;Hong, Seok-Won;Lee, Sanghyup;Choi, Yong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.329-336
    • /
    • 2008
  • The pilot study was conducted to evaluate the applicability of air flotation(AF) processes combined with biological nutrient removal(BNR) for the retrofitting of conventional wastewater treatment facilities. The BNR system was operated in pre-denitrification and intermittent aeration; developed ceramic membrane diffusers were installed to separate the solid-liquid of activated sludge at the bottom of a flotation tank. Before performing a pilot scale study, the size distribution of microbubbles generated by silica or alumina-based ceramic membrane diffusers was tested to identify the ability of solid-liquid separation. According to the experimental results, the separation and thickening efficiency of the alumina-based ceramic membrane diffuser was higher than the silica-based ceramic membrane diffuser. In a $100m^3/d$ pilot plant, thickened and return sludge concentration was measured to be higher than 15,000mg SS/L, therefore, the MLSS in the bioreactor was maintained at over 3,000mg SS/L. The effluent quality of the AF-BNR process was 4.2mg/L, 3.7mg/L, 10.6mg/L and 1.6mg/L for $BOD_5$, SS, T-N and T-P, respectively. Lastly, it was revealed that the unit treatment cost by flotation process is lower than about $1won/m^3$ compared to a gravity sedimentation process.

Conversion of Organic Carbon in Food Processing Wastewater to Photosynthetic Biomass in Photo-bioreactors Using Different Light Sources

  • Suwan, Duangkamon;Chitapornpan, Sukhuma;Honda, Ryo;Chiemchaisri, Wilai;Chiemchaisri, Chart
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.293-298
    • /
    • 2014
  • An anaerobic photosynthetic treatment process utilizing purple non-sulfur photosynthetic bacteria (PNSB) was applied to the recovery of organic carbon from food processing wastewater. PNSB cells, by-product from the treatment, have high nutrition such as proteins and vitamins which are a good alternative for fish feed. Effects of light source on performance of anaerobic photosynthetic process were investigated in this study. Two bench-scale photo-bioreactors were lighted with infrared light emitting diodes (LEDs) and tungsten lamps covered with infrared transmitting filter, respectively, aiming to supply infrared light for photosynthetic bacteria growth. The photo-bioreactors were operated to treat noodle-processing wastewater for 323 days. Hydraulic retention time (HRT) was set as 6 days. Organic removals in the photo-bioreactor lighted with infrared LEDs (91%-95%) was found higher than those in photo-bioreactor with tungsten lamps with filter (79%-83%). Biomass production in a 150 L bench-scale photo-bioreactor was comparable to a 8 L small-scale photo-bioreactor in previous study, due to improvement of light supply efficiency. Application of infrared LEDs could achieve higher treatment performance with advantages in energy efficiency and wavelength specifity.

Studies on the Wastewater of General Hospital and It에s Treatment -Effects of Disinfectants on Activated Sludge Process- (病院廢水의 特性과 處理에 關한 硏究 -消毒劑가 활성스러지법에 미치는 영향-)

  • Ra, Kyu Hwan;Ok, Chi Sang
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.1
    • /
    • pp.13-20
    • /
    • 1984
  • The hospital wastewaters have to be so disposed as to prevent disease and to protect water resources from hazardous substances disinfectants, medicines, and chemicals. Polyvinylpyrrolidone-iodine complex (povidone-iodine) is widely used in the hospital as one of disinfectants. This study was carried out to manifest the effect of disinfectants in growth of activated sludge in treatment of the hospital wastewater by the activated sludge process. The results are as follow. 1. An average water quality of the hospital wastewater showed 7.2 in pH, 3.2 ppm in DO, 293.3 ppm in SS, 96.0 ppm in BOD, 151.1 ppm in COD, 0.4 ppm in povidone-iodine, 0.5 ppm in phenols, 5.4 ppm in surfactants, 1.6 ppm in o-phosphate, 4.6 ppm in $NH_3-N, 249\times 10^4$ counts/100 ml in coliform group organisms, and $1,369\times 10^2$ counts/ml in general counts of bacteria. And wastewater amounts discharged per bed was calculated 70 l/d/bed. 2. In batch culture activated sludge process, each of cresol and povidone-iodine was not effected in less than 0.1 ppm concentration, but the more concentration, the more inhibit the growth rate of activated sludge. In the mixture of two disinfectants, the growth was more inhibited the effect of single disinfectants. So that this reaction is considered as addition effect of two disinfectants. 3. The removal rates of the disinfectants-by continuous culture activated sludge process were 77.6% in 0.4 ppm povidone-iodine, and in BOD was 85.6%. 4. It is desirable that the hospital wastewater is planed in order to be discharged to two system separately, sewer from life system and wastewater from medical system. From those results, it has been concluded that the hospital wastewater has to be treated safely by the activated sludge process.

  • PDF

The Treatment of Animal Wastewater by the Combination of Trickling Filter System and Activated Sludge Process (살수여상 활성오니 연계방법에 의한 축산뇨요수 처리)

  • Ryoo J. W.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.81-86
    • /
    • 2004
  • This experiment was conducted to evaluate combination system of wood chip trickling system and activated sludge process. The results obtained are summarized as tallows. The trickling filter system using wood chip was used as a biological pre-treatment system for treating piggery wastewater. At pre-treatment the removal efficiencies were BOD $91\%$ CODmn $65\%$, SS $75\%$ T-N $73\%$, T-P $69\%$. After pre-treatment the removal efficiencies in activated sludge process were BOD $99\%$ CODmn $94.6\%$, SS $97.8\%$ T-N $91.1\%$, T-P $91\%$. This study shows a very stable method with pre-treatment of trickling filter using wood chip. These combined treatment system was very useful for piggery wastewater.

  • PDF