• 제목/요약/키워드: Wastewater treatment

검색결과 3,321건 처리시간 0.029초

화학적 처리에 의한 1차 하수처리장의 처리효과 개선 -현장시험을 중심으로- (Chemically Enhanced Primary Treatment at D Wastewater Treatment Plant)

  • 곽종운;김승현;이찬원
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.99-108
    • /
    • 1997
  • This study examined the feasbility of upgrading D waste water treatment plant which treats incoming wastewater by primary sedimentation only. By adding 20-40 ppm of Hi-PAX into the outlet of the aerated grit chamber, BOD and SS removal efficiences were improved from 29% and 36% to 53 % and 73%,respectively. However, chemically enhanced primary treatment failed to meet the upcoming wastewater quality standard(BOD and SS <20 mg/l) consistently. This was suspected to result from the deteriorated plant return stream. The wastewater treatment by chemical treatment should have increased the amount of the sludge to be removed as the sludge production was increased. Chemically enhanced primary treatment is anticipated to consistently produce effluent of the 1996 standards quality by adjusting the amount of the sludge to be removed. Besides BOD and SS removal, chemically enhanced primary treatment resulted in the improved T-P removal from 30% to 64-74%. However, such benefit was not observed in T-N removal. Improved T-P removal will be expected to help control water pollution in Masan bay.

  • PDF

은 함유 폐수의 연속 순환 전해처리 시 유량변화가 회수 공정에 미치는 영향 (Effect of Flow Rate on the Continuous Cycling Electrolytic Treatment Process for Silver Ion Containing Wastewater)

  • 정원주;김동수
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.577-580
    • /
    • 2007
  • The influence of flow rate has been investigated on the treatment efficiency of continuous cycling electrolytic process employing artificial and actual photographic wastewater which containing silver ion. For artificial wastewater, the treatment efficiency of process was found to rise ca. three times when the flow rate of wastewater was increased from 3 mL/min to 15 mL/min. The process efficiency was doubled under the same condition regarding actual wastewater. The effect of flow rate on the treatment efficiency was observed to be altered according to the metal ionic form and solution composition. The coefficient of mass transfer was estimated using model equation, which verified that the raised treatment efficiency at higher flow rate was due to the increased mobility of ionic species.

하수종말처리장 방류수를 밭작물 관개용수로 처리시 시금치와 배추의 생육, 대장균 분포 및 토양의 질 평가 (Growth Response and Total Coliform Distribution of Spinach and Chinese Cabbage and Soil Quality by Irrigation of Domestic Wastewater)

  • 조재영;박승우;손재권;박봉주;이용근
    • 농촌계획
    • /
    • 제12권2호
    • /
    • pp.57-64
    • /
    • 2006
  • The experiment was carried out to determine the distribution of total coliform the translocation of heavy metals and the salt accumulation in soils following the supply of ground water, the domestic wastewater and the ultraviolet treatment of domestic wastewater during the spinach and the chinese cabbage cultivation. There were not much changes in the Total-N, Total-P and cations in soils following the ultraviolet treatment of the domestic wastewater. However, the density of total coliform was dramatically reduced from 894MPN/100mL to 5MPN/100mL. The diagnosis of composition of soil after the harvest of chinese cabbages and spinach has shown that the concentration of Na$^+$ was 3-4 times higher in plot using domestic wastewater than in plot using ground water. When domestic wastewater and ground water were used in growing spinach md chinese cabbage at 50% each, the application of chemical fertilizers reduced about 25% to 50% compared to the criteria set down by the Rural Development Administration and there was not significant difference in terms of harvest. Using non-ultraviolet treatment of domestic wastewater directly on spinach and chinese cabbage has resulted in excessive density of total coliform at 25,000MPN/100mL. Even when ultraviolet treatment, the density was still high at 2,000MPN/100mL. The high density of total coliform even following ultraviolet treatment of domestic wastewater is considered to be caused by photo-reactivation of micro-organism. When reusing domestic wastewater, the application of sterilization such as ultraviolet, ultrasonic and electron-beam for public health and hygiene reasons may provide safe supply of agricultural water.

화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선 (Saturation curves for chemical coagulation of wastewater treatment)

  • 류재나;오재일;이경종
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

호기성 공동대사작용에 의한 판지폐수처리 - 현장 적용 테스트 - (The Treatment of Box-mill Wastewater Using Aerobic Cometabolism Process - Practical Plant Test -)

  • 조용덕;이상화
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.128-137
    • /
    • 2006
  • This study aims at developing the practical technology in the treatment of box-mill wastewater using the aerobic co-metabolism principle. The conventional activated sludge method exhibited the removal efficiency of $TBOD_5$ and $TCOD_{Mn}$ as 30~50% and 40~50%, respectively. Color was rather increased by 30~130% because the conventional treatment under the aerobic condition did not induce the conversion of molecular structure of dyeing agents. Meanwhile, when the aerobic co-metabolism principle was applied to the same wastewater, the removal efficiency of $TBOD_5$ and $TCOD_{Mn}$ were obtained as 92~97% and 90~94%, respectively. In particular, color was significantly reduced down to 65~85%. The enhancement of treatment efficiency was ascribed to occur not only that the non-degradables were converted to the second substrates, but also that the enzyme activity was increased as MLVSS was kept 3000mg/l or more with the first substrates injected.

Porous polymer membranes used for wastewater treatment

  • Melita, Larisa;Gumrah, Fevzi;Amareanu, Marin
    • Membrane and Water Treatment
    • /
    • 제5권2호
    • /
    • pp.147-170
    • /
    • 2014
  • This paper focuses on the study of the most recent ultra-filtration techniques, based on porous polymer membranes, used for the treatment of wastewater from oil, mine and hydrometallurgical industries. The performance of porous membranes used in separation and recovery of oil and heavy metals from wastewater, was evaluated by the polymer composition and by the membrane characteristics, as it follows: hydrophobicity or hydrophilicity, porosity, carrier (composition and concentration), selectivity, fouling, durability, separation efficiency and operating conditions. The oil/water efficient separation was observed on ultra-filtration (UF) techniques, with porous membranes, whereas heavy metals recovery from wastewater was observed using porous membranes with carrier. It can be concluded, that in the ultra-filtration wastewater treatments, a hybrid system, with porous polymer membranes with or without carrier, can be used for these two applications: oil/water separation and heavy metals recovery.

화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구 (A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater)

  • 박선구;고오석;신대윤
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

산업폐수처리장 방류수의 내분비계 장애작용 평가 (Endocrine Disrupting Effects of the Industrial Wastewater Effluents Discharged from the Treatment Plant)

  • 오승민;김기서;유병택;장형석;이희성;정규혁
    • Environmental Analysis Health and Toxicology
    • /
    • 제19권4호
    • /
    • pp.375-382
    • /
    • 2004
  • This study was designed to investigate potential endocrine disrupting effects of several industrial wastewater effluents discharged from cosmetic, plaiting, paint, textile industry using EROD bioassay and E-Screen assay. The results of E-screen assay showed that textile industrial wastewater could act as a full agonist and cosmetics and plaiting industrial wastewater could act as a partial agonist. On the contrary, the wastewater discharged from paint industry did not show any estrogenic effect. Estrogenic activity in the effluents of cosmetic and paint industrial wastewater was lower than that in the influents indicating that the wastewater treatment process minimized the effects of discharges on water quality. Despite of these results, it was recognized that wastewater treatment was not always minimize toxic impact. In this study, increased estrogenic effect was observed in the effluents of plating and textile wastewater, and EROD activity was increased in the effluents of cosmetic and plating wastewater.

The Effect of Photocatalysis using $TiO_2$ and UV for COD Degradation of Wastewater in Linerboard Mill

  • Kang, Kwang-Ho;Kim, Hyoung-Jin
    • 펄프종이기술
    • /
    • 제40권5호
    • /
    • pp.53-59
    • /
    • 2008
  • This study was carried out to investigate the effect of photocatalysis using $TiO_2$ and UV applied for the COD reduction of wastewater in linerboard mill. Trials were done to obtain the optimum addition amounts of $TiO_2$ and $H_2O_2$ to the wastewater and find an appropriate pH condition for photocatalysis on $TiO_2$ for degrading COD. The photocatalytic reaction was applied to the wastewater collected after secondary activated sludge treatment in WWTP of linerboard mill. The optimum application of photocatalysis reaction was obtained under the addition conditions of 2 g/L of $TiO_2$ and 200 mg/L of $H_2O_2$ at pH 3.0, respectively. The removal efficiency of $SCOD_{Cr}$ by photocatalytic treatment was 86.4 % and higher than Fenton treatment in which removal efficiency was 67.4 %. It was concluded that the photocatalytic process using $TiO_2$ and UV could be applied to the wastewater treatment in linerboard mill and also to the dramatic drop-off in NBDCOD load from wastewater of tertiary treatment in WWTP.

제올라이트와 감마선을 이용한 축산 폐수 처리 (Livestock Wastewater Treatment by Zeolite Ion Exchange and Gamma-ray Irradiation)

  • 이상률;김탁현;이면주
    • 방사선산업학회지
    • /
    • 제2권1호
    • /
    • pp.9-14
    • /
    • 2008
  • Livestock wastewater containing high concentrations of organic matters and ammonia-nitrogen has been known as one of the recalcitrant wastewater. It is difficult to treat by conventional wastewater treatment techniques. This study was carried out to evaluate the feasibility of zeolite ion exchange and gamma-ray irradiation treatment of livestock wastewater. The removal efficiencies of $SCOD_{Cr}$ and $NH_3-N$ were significantly enhanced by gamma-ray irradiation after zeolite ion exchange as a pre-treatment. However, the effects of zeolite particle size on the $SCOD_{Cr}$ and $NH_3-N$ removal efficiencies were insignificant. These results indicate that the combined process of zeolite ion exchange and gamma-ray irradiation has potential for the treatment of livestock wastewater.