• Title/Summary/Keyword: Wastewater recycling

Search Result 304, Processing Time 0.045 seconds

Anaerobic digestion for food wastewater using HADS Pilot Plant and analysis of microbial community in the digester (HADS Pilot Plant를 이용한 음폐수의 혐기성 소화 및 미생물 군집 변화 분석)

  • Ju, Dong-Hun;Lee, Jung-Min;Park, Seong-Bum;Sung, Hyun-Je;Bae, Jae-Sang;Sang, Byoung-In
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2010
  • We(Hansol EME Co. Ltd.) proceeded anaerobic digestion test for domestic food wastewater applying to two operating method for increasing of OLR. The methods are as follows. One was the rapidity operating method which was increasing the OLR continuously and rapidly and the other was the terraced operating method which was increasing the OLR having adaptation period for each step. As a result of this tests, the ratio of VFA/Alkalinity of the process was very unstable under the rapidity operating method then the volume of produced biogas was dramatically decreased. However the process was shown stable performance under the terraced operating method maintaining the ratio of VFA/Alkalinity less than 0.4. Also, the process was performing the biogas recovery of $0.8Nm^3/kgVS_{rem}/d$ and the VS removal ratio of 85%. T-RFLP analysis about the community of bacteria and methanogen is also conducted to check the change of the microbial community according to the methods of OLR increasing operation. The microbial community was changed by the methods of OLR increasing operation according to the result of T-RFLP analysis. Although the anaerobic digestion test was executed by same pilot plant, the reactivity and the tolerance of microbial community for surrounding environment could be considerably changed by the operating method for the process.

Reduction of Salt Concentration in Food Waste by Salt Reduction Process with a Rotary Reactor (로터리식 저염화 공정설비에 의한 음식물 쓰레기의 염분농도 저감)

  • Kim, Wi-sung;Seo, Young-Hwa
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • In order to reduce salt(as NaCl) contents in food waste and to improve the quality of discharged wastewater produced during the recycling process of food waste for the purpose of compost and feed stuff, a salt reduction process by added water into food waste was developed. The pilot plant with a rotary type salt reduction equipment to manage continuously 0.5 ton food waste per hour was constructed and the efficiency was tested. The amount of added water was calculated by the water content and the efficiency of dewatering process of food waste. Approximately 0.8 liter water per a kilogram of food waste was injected into the reactor in which food waste was pouring simultaneously, then diluted/mixed in a rotary reactor. About 1.1 liter of leachate including added water was generated, but the leachate contained a very high content of organic particles, so most particles were recovered by two step solid-liquid separation process. The first step was a gravitational filtering process using screens with a pore diameter of 1mm, and the second separation process was centrifugal process. Organic quality of food waste which had been desalted was maintained by inputting the entirely recovered organic particles. The efficiency of salt reduction of food waste was estimated by measuring a chloride anion by titration and salinity by a probe. The results by the two different measuring methods were always over 50%, and the quality of final wastewater was improved up to $200mg/{\ell}$ as TS(total solid) by an additional settling process after the two step solid-liquid separation process.

  • PDF

Characteristics of Air Stripping for Recycling of Ammonia in Aqueous Solutions (수용액중 암모니아 Recycling을 위한 Air Stripping 특성에 관한 연구)

  • Lee Hwa-Yaung;Oh Jong-Kee;Kim Sung-Gyu
    • Resources Recycling
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 2003
  • A study on the characteristics of ammonia desorption from aqueous solutions has been performed by air stripping as the first stage of ammonia recycling for the preparation of ammonium sulfate from it. For air stripping experiments, a stripping column made with acrylic tube of 40 mm diameter was employed and compressed air was injected into solutions through air sparger equipped at the bottom of stripping column. As a result of experiments, the stripping efficiency was increased with the aqueous pH and it was found that the appropriate pH for air stripping of ammonia was between pH 10 and 12. As far as the effect of air flow rate on ammonia stripping was concerned, ammonia stripping was not proportional to the air flow rate although it was affected by the air flow rate to some extent. Moreover, when more than 20 cm of water height was maintained, total ammonia desorbed from solution was not varied with the water height. Stripping temperature was also found to play an important role in ammonia desorption and about 90fo of initial ammonia was desorbed in 14 hours at pH 12.8 and at $60^{\circ}C$ Finally, it was believed that stripping temperature as well as the aqueous pH was one of the most important factors in air stripping of ammonia.

Sludge Disposal Analysis of Sanitary Paper Manufacturing Wastewater Treatment Plant (위생용지 생산 제지공장 폐수슬러지의 처리 현황)

  • Jung, Yong-Jun;Lee, Hong-Tae
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.471-476
    • /
    • 2013
  • The operating conditions of sludge disposal for sanitary paper manufacturing wastewater treatment plant were monitored on the basis of daily check sheets during the 3 years of operation. Generated wastes were mainly composed of 79% of sludge, 14% of ash, 5% of waste synthetic resin and 2% of etc. Maximum sludge was produced to 233 ton and the average was 113 ton daily, where the primary sludge occupied 85% and 15% for the secondary sludge. The concentration of coagulant for sludge dewatering was extremely exceeded and the additional experiment such as jar-test was required for the establishment of proper dosage. Presently, the generated sludges were partially treated outside and were also partly handled inside. In the future, most sludges will be expected to be treated to recycling material for the iron industry.

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.7
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

Recovery of High Concentrated Phosphates using Powdered Converter Slag in Completely Mixed Phosphorus Crystallization Reactor (완전혼합형 정석탈인반응조에서 미분말 전로슬래그를 이용한 고농도 인의 회수)

  • Kim, Eung-Ho;Yim, Soo-Bin;Jung, Ho-Chan;Lee, Eok-Jae;Cho, Jin-Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.59-65
    • /
    • 2005
  • A phosphate recovery system from artificial wastewater was developed using a completely mixed phosphorus crystallization reactor, in which powdered converter slag was used as a seeding crystal. In preliminary test, the optimal pH range for meta-stable hydroxyapatite crystallization for high phosphorus concentration was observed to be 6.0 to 7.0, which was different from the conventionally known pH range (8.0~9.5) for effective crystallization in relatively low phosphorus concentration less than 5 mg/L. The average phosphorus removal efficiency in a lab-scaled completely mixed crystallization system for artificial wastewater with about 100 mg/L of average $PO_4-P$ concentration was shown to be 60.9% for 40 days of lapsed time. XRD analysis exhibited that crystalline of hydroxyapatite formed on the surface of seed crystal, which was also observed in SEM analysis. In EDS mapping analysis, composition mole ratio (=Ca/P) of the crystalline was found to be 1.78, indicating the crystalline on the surface of seed crystal is likely to be hydroxyapatite. Particle size distribution analysis showed that average size of seed crystal increased from $28{\mu}m$ up to $50{\mu}m$, suggesting that phosphorus recycling from wastewater with high phosphorus concentration can be successfully obtained by using the phosphorus crystallization recovery system.

Effects of Magnetite(Fe3O4) as Electrical Conductor of Direct Interspecies Electron Transfer on Methane Yield of Food Wastewater (종간직접전자전달 전도체로서 Magnetite(Fe3O4)가 음폐수의 메탄생산에 미치는 영향)

  • Jun-Hyeong Lee;Tae-Bong Kim;Chang-Hyun Kim;Young-Man Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.15-26
    • /
    • 2023
  • Methane production by anaerobic digestion occurs through interspecies electron transfer (DIET), a synthetic metabolism between acetic and methanate bacteria through hydrolysis and acid production steps. In this study, to improve methane yield, the effect of addition of magnetite (Fe3O4), a conductor promoting DIET on methane production in food wastewater was investigated, and the effect on methane yield was assessed by methane potential (Bu) and maximum methane production rate [Rm(t0)] by the operation of batch type anaerobic reactor adding Fe3O4. The Bu and Rm(t0) of food wastewater without Fe3O4 were 0.496 Nm3/kg-VSadded and 38.24 mL/day, respectively. The t0 which reached to Rm appeared at 21.06 days during the operation of the anaerobic reactor. The Bu of food wastewater with Fe3O4 was 0.502, 0.498, 0.512, 0.510, 0.518, 0.523, 0.524, 0.540, and 0.549 Nm3/kg-VSadded in the treatment of 5, 10, 15, 20, 25, 30, 40, 70, and 100mM-Fe3O4, respectively, and the Bu significantly increased to 36.95% with the addition of magnetite in the addition of 15mM-Fe3O4. And, the addition of Fe3O4 shortened the duration to reach Rm from 21.06 days to the maximum of 14.67 days by the addition of Fe3O4. Therefore, the methane yield and production rate of food wastewater significantly improved with the addition of Fe3O4.

A Management Plan of Wastewater Sludge to Reduce the Exposure of Microplastics to the Ecosystem (미세플라스틱의 환경노출을 최소화하기 위한 하·폐수 슬러지 관리방안)

  • An, Junyeong;Lee, Byung Kwon;Jeon, Byong-Hun;Ji, Min-Kyu
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • Due to the negative impacts of microplastics (MPs) on the ecosystem, the investigation of its occurrence and its treatment from sewage and wastewater treatment plants (WWTPs) have received a lot of attention in the recent years. Most MPs are precipitated and removed with the sludge during the treatment process. Proper sludge management is immensely necessary to avoid MP exposure in the environment. However, the domestic research on this aspect is limited. This study reviews appropriate sludge management approaches to decrease environmental MP exposure. This can be achieved through investigating sludge generation and treatment, regulation laws and government policy trends with an emphasis on WWTPs. The ratio of sludge in sewage treatment plants has been observed to be highest in recycling followed by incineration and landfills. Recycling is the highest in fuel followed by construction materials and composting. For WWTPs, the highest ratio is in recycling followed by fuel and landfills, and recycling is confirmed in the following order: incineration > after composting > after solidification > earthworm breeding. Treatment approaches that can increase the exposure of MPs to the ecosystem are considered to be used in landfills and agricultural fields. However, this method is not appropriate given the insufficient capacity of domestic landfills and the sufficient supply of existing chemical and animal manure fertilizers. Instead, it would be rational in terms of environmental preservation to expand the use of fuel and energy in connection with the new and renewable energy policy, and to actively seek the use of sub-materials for construction materials. In order to secure the basic data for the effectiveness of future planning and revision of related laws, it is required to perform an in-depth investigation of the sludge supply and demand status along with the environmental and economic effects.

Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process (음폐수 부하량에 따른 고온호기성 공정의 처리 양상)

  • Jang, Hyun Min;Choi, Suk Soon;Ha, Jeong Hyub;Park, Jong Moon
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • In this study, the feasibility of a single-stage thermophilic aerobic process for the treatment of high-strength food wastewater produced from the recycling process of food wastes was examined to substitute anaerobic digestion process. Also, the removal and stability of thermophilic aerobic process were assessed according to the changes of hydraulic retention times (HRTs) and organic loading rates (OLRs). When the OLR increased from 9.2 to $37.2kgCOD/m^3d$, a pH value in R1 (HRT : 5 d) significantly decreased to 5.0, due to the organic acid accumulation. On the other hand, the pH value in R2 (HRT : 10 d) was stable and R2 showed the high removal of COD, organic acid and lipid, even though the OLR increased from 4.6 to $18.6kgCOD/m^3d$. In R1, the COD loading rates for COD removal was suddenly dropped, as the COD loading rate increased from 18.6 to $28.4kgCOD/m^3d$. In contrast, R2 showed that the COD loading rates for COD removal increased with regard to increment in the loading rates of 3.61, 7.05, 9.43 and $12.2kgCOD/m^3d$, indicative of the high COD removal efficiency. Therefore, the results demonstrated that over 10-d HRT, the high concentration of raw food wastewater was efficiently treated in the single-stage thermophilic aerobic process.

A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process (질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon;Song, Su-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • This study was performed under four operational conditions for nitrogen removal in metal finishing wastewater. The conditions include electrode gap, reducing agent, the recycling of treated wastewater in 1st step and the simultaneous treatment of nitrate and other materials. Result showed that the removal efficiency of $NO_3{^-}-N$ was highest at the electrode gap of 10 mm. As the electrode gap was shorter than 10 mm, the removal efficiency of $NO_3{^-}-N$ decreased due to increasing in concentration polarization on electrode. And, in case that the electrode gap was longer than 10 mm, the removal efficiency of $NO_3{^-}-N$ increased with an increase in energy consumption. Because hydrogen ions are consumed when nitrate is reduced, reducing reaction of nitrate was effected more in acid solution. As 1.2 excess amount of zinc was injected, the removal efficiency of $NO_3{^-}-N$ increased due to increasing in amount of reaction with nitrate. As the effluent from 1st step in the reactor was recycled into the 1st step, the removal efficiency of $NO_3{^-}-N$ increased. Because the zinc were detached from the cathode and concentration-polarization was decreased due to formation of turbulence in the reactor. The presence of $NH_4{^+}-N$ did not affect the removal efficiency of $NO_3{^-}-N$ but the addition of heavy metal decreased the removal efficiency of $NO_3{^-}-N$. As chlorine is enough in wastewater, the simultaneous treatment of nitrate and ammonia nitrogen may be possible. The problem that heavy metal decrease the removal efficiency of $NO_3{^-}-N$ may be solved by increasing current density or using front step of electrochemical process for heavy metal removal.