• Title/Summary/Keyword: Wastewater plants

Search Result 555, Processing Time 0.031 seconds

A Study on the Applicability of ENERWATER for Evaluation of the Energy Consumption Label of WWTPs in Korea (국내 하수처리시설 에너지 등급 평가를 위한 ENERWATER의 적용 가능성에 관한 연구)

  • Park, Minoh;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.5
    • /
    • pp.231-239
    • /
    • 2022
  • In this study, we applied ENERWATER to evaluate the energy consumption labeling of wastewater treatment plants in Korea using the Korea sewerage statistics data. The results showed that the energy label status was excellent in the SBR process for small and medium-scale wastewater treatment plants and the A2O process for large-scale wastewater treatment plants. The energy labeling of wastewater treatment plants of 50,000 tons capacity was excellent. The statuses of metropolitan cities and Jeollanam-do province were excellent. We analyzed the effects of renewable energy on wastewater treatment plants' energy consumption and found out that digestion gas for large-scale plants and photovoltaic energy for small-scale plants were effective in improving energy labeling. In addition, we compared the energy labels of four wastewater treatment plants in "Z" city and wastewater treatment plant "X" had the best energy label, and the wastewater treatment plants "V" and "Y" had to be selected as priorities for the energy diagnosis and improvement project. In a comprehensive conclusion, the applicability of ENERWATER was confirmed based on sewage statistics data and labeling can be used to set priorities for the energy diagnosis and improvement project.

A Study of Optimum Operational Methods for Domestic Wastewater Treatment Plants in Korea (국내 하수종말처리장 최적 운전 방안에 관한 연구)

  • Lee, Byong-hi;Lee, Woung-Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • The optimum operation of domestic wastewater treatment plant can give influence on operational cost and future expansion in Korea where has 93 operational domestic wastewater treatment plants. Also, the study on optimum operation can reduce operation cost and budget of municipalities whom have responsibility of wastewater treatment plant operation. In this study, 9 domestic wastewater treatment plants which can represent 93 plants in Korea have been selected and operational data are gathered. The collected data are inputted to computer simulator based on IAWQ's Activated Sludge Model No.1 and optimum operation methods are developed. Also, the electric power for aeration which has large portion of overall operation cost are calculated based on design and operation conditions and these are compared. In this study, it was found that design wastewater characteristics are 1.6 times higher than those of daily maximum except for E plant and that estimation methods for design wastewater characteristics have to be improved. Based on computer simulation, we found there is no need to operate all aeration tanks due to weak influent overall power for aeration can be reduced to about 43% of design one.

  • PDF

Evaluation of monthly environmental loads from municipal wastewater treatment plants operation using life cycle assessment

  • Piao, Wenhua;Kim, Ye-jin
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.284-290
    • /
    • 2016
  • Life cycle assessment (LCA) methodology can be used to assess impacts on the environment that might be generated during treatment of wastewater and sludge treatment. In this work, LCA methodology was suggested to evaluate monthly environmental impact of wastewater treatment plants (WWTPs). Two field scale WWTPs, A2/O process and conventional activated sludge process (CAS), were selected as target plants and the operational data were collected from those plants. As the function units, the unit volume of treated wastewater of $1m^3$ and 1 kg T-N eq. removed were selected. The environmental effect of target WWTPs operation were assessed as impact categories such as global warming potential, eutrophication potential, and so on. From monthly profiles of each index, it was shown that the environmental impact of WWTPs has seasonal patterns influenced by the influent flow rate variation causing higher impacts in winter than summer. This is due to the fact that there were no significant increase in the electricity consumption and chemical usage during the summer while the treated volume of wastewater was increased.

Investigation of Effluent of Wastewater Treatment Plants for Agriculture Reuse (농업용수재이용을 위한 하수처리장 현황조사)

  • Lee, Gwang-Ya;Kim, Hae-Do;Jeong, Gwang-Geun;Lee, Jong-Nam
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.521-526
    • /
    • 2005
  • Water Quality of effluent from wastewater treatment plants was reviewed to reuse effluent for agricultural water as alternative water resources. Among 2004, wastewater treatment plants, 19 plants are found to be used as wastewater resources applicable to irrigation. The total effluent capacities are 9,293 thousand $m^3$per day, which may be used to irrigate paddy fields. In order to know how much the effluent can be use for agricultural water, we classified the effluent according to the river basin area and evaluated the water quality of the effluent.

  • PDF

Statistics and Probability Distribution of Total Coliforms in Wastewater (하수에서의 대장균수 확률분포 특성 분석)

  • Jun, Sang Min;Song, Inhong;Jeong, Han Seok;Kang, Moon Seong;Park, Seung Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.105-111
    • /
    • 2013
  • Probability distribution of microbes in wastewater is a crucial factor to be determined for microbial risk assessment associated with its reuse. The objective of this study was to investigate probability distribution of an indicator microorganism in wastewater. Daily total coliform counts measured from nationwide wastewater treatment plants in 2010 by the Ministry of Environment were used for statistical analysis. Basic statistics and probability distributions were estimated in the three different spatial scales using the MS Excel software and FARD2006 model. Overall, wastewater from manure and livestock treatment plants demonstrated greater median coliform counts than from sewage and village treatment plants. Generalized logistic (GLO) and 2-parameter Weibull (WBU2) appeared to be the two probability distributions that fitted best for total coliform numbers in wastewater. The study results of microbial statistics and probability distributions would provide useful data for quantitative assessment of microbial risk from agricultural wastewater reuse.

Salt and NH$_4^+$-N Tolerance of Emergent Plants for Constructed Wetlands (정수식물의 내염성 및 NH$_4$^+$-N 흡수제거능 평가)

  • 이충일;곽영세
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.45-49
    • /
    • 2000
  • Tolerances of aquatic plants (emergent plants) of cattail (Typha orientalis), water oats (Zizania latifolia), reed (Phragmites communis), and bulrush (Scirpus nipponicus) to salts and high NH₄/sup +/-N cone. of industrial wastewater were evaluated. Evapotranspiration of cattail and water oats plants was not affected when the wastewater containing 130 ppm NH₄/sup +/-N with electrical conductivity of 3.0 dS/m was supplied for 5 months. Shoot and root dry wt. of cattail and water oats were rather increased by irrigation of the wastewater while the biomass production of bulrush was greatly reduced. Storage nitrogen concentration in tissues of water oats and reed plants were higher than those in cattail and bulrush. Thus, water oats and reed plants were found to be the better aquatic plants to use in constructed wetlands for treating industrial wastewater of high salt and NH₄/sup +/-N.

  • PDF

Wastewater Characteristics for Slaughtering Plants in Seoul (서울시 도축폐수의 오염 특성에 관한 연구)

  • Lee, Sang Ho;Kim, Young-Ran;Chung, Jae-Chun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.5 no.2
    • /
    • pp.1-6
    • /
    • 1997
  • Three plants for slaughtering cattle and hogs are located within 13 km away from Ithe downtown of Seoul. They are Woosung at Majang-dong, Hyubjin at Doksan-dong and Chookhyup at Garak-dong. The Objectives of this research are 1) to investigate the current status of three plants 2) to investigate wastewatrer characteristics for slaughtering platns, 3) to find out the pollution loadings to the Han river. The conclusions drawn from this research are given below: (1) The ratio of BOD/COD from the wastewater for three plants is 0.8~0.9. Most components of watewater can be biodegradable. (2) The pollution unit of BOD/cattle hog was the 726 g for Chookhyup, 777 g for Woosung and 797 g for Hyupjin plant. The average pollution unit of wastewater was 767 g BOD/cattle hog for slaughtering plant and $112.6g/m^2{\cdot}d$ for meat markets wastewater. (3) The total pollution loading was 5,050 kg/day for three wastewater plants and this amount can be affected as much as 1 % of total pollution loading of the Han River.

  • PDF

A Study on Current Energy Consumption and Recycling at Public Wastewater Treatment Plants in Korea (국내 공공하수도 시설의 에너지 사용 및 자원화실태 조사연구)

  • Park, Seungho;Kim, Byongjoo;Bae, Jae-Ho;Lee, Cheol Mo;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.539-549
    • /
    • 2007
  • To establish effective and prompt measures for energy conservation in public wastewater treatment plants in Korea, energy consumption rates in 233 utilities in 9 provinces and 7 metropolitan cities are investigated and compared to the rest of the world. Mean load factor for wastewater treatment utilities is 74.9% and those for influent pumps and aeration blowers are 56.2% and 61.0%, respectively. Mean electrical energy usages as the key performance indicators are $0.243kWh/m^3$ for overall sewage treatments and 2.07 kWh per unit kg BOD removal. Digester gas as one of major byproducts in the process amounts to $382,000m^3/day$ nationwide. While major part of the digester gas is used for sludge heating, only 7.3% of the gas is utilized for electricity generation. Both efficiencies for BOD removal and digestion gas generation are considerably lower than those in USA and EU utilities due to low concentration of organic material in influent wastewater. Such low energy regeneration, in turn, results in significantly higher energy consumption in Korean plants, compared to that in USA and EU ones.

A Study on the Foam Wastewater Treatment and Foam Collection by Inhalation Force at the Outlet of Power Plants (발전소 방류구의 흡입력을 이용한 거품수거 및 거품액 처리 연구)

  • Jang, Heui-Su;Mun, Gyeng-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.496-499
    • /
    • 2005
  • Power Plant is requested, by environmental bodies and fisherman, to correct the pollution of coastal area due to the outflow of foam from the outlet of the power plants. Foam wastewater cause a lot of environmental problems, expecially in aesthetic points of view. Therefore, It is needed to be collect from the stream into nearby ocean, and the collected foams should be treated before being discharged into nearby ocean. The most effective and feasible treatment method researched for the effective treatment of foam wastewater generated at the power plants. The result of the test is confirmed with collecting Foam wastewater by inhalation force. The treatment pilot ($3m^3/hr$) collected wastewater was operated by Biological degradation method(Aerobic/anaerobic Processes) for approximately two months. It was removed SS, COD, nutrient(T-P, T-N), etc. The System is expected successfully by Minimizing the operating costs such as electricity, repair expenses, chemicals and supplies expenses.