A Study on the Foam Wastewater Treatment and Foam Collection by Inhalation Force at the Outlet of Power Plants  

Jang, Heui-Su (Korea Southern Power co. LTD Hadong thermal power site Division)
Mun, Gyeng-Seok (Korea Southern Power co. LTD Hadong thermal power site Division)
Publication Information
Abstract
Power Plant is requested, by environmental bodies and fisherman, to correct the pollution of coastal area due to the outflow of foam from the outlet of the power plants. Foam wastewater cause a lot of environmental problems, expecially in aesthetic points of view. Therefore, It is needed to be collect from the stream into nearby ocean, and the collected foams should be treated before being discharged into nearby ocean. The most effective and feasible treatment method researched for the effective treatment of foam wastewater generated at the power plants. The result of the test is confirmed with collecting Foam wastewater by inhalation force. The treatment pilot ($3m^3/hr$) collected wastewater was operated by Biological degradation method(Aerobic/anaerobic Processes) for approximately two months. It was removed SS, COD, nutrient(T-P, T-N), etc. The System is expected successfully by Minimizing the operating costs such as electricity, repair expenses, chemicals and supplies expenses.
Keywords
Foam wastewater; Foam collect; Inhalation force; Degradation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 임영환, 배복규, 발전소 가동시 발생되는 해수거품의 성질과 거품저감 대책, 전력기술, pp. 6-17 (1995)
2 한국전력기술주식회사, 발전소 가동시 배수구 주위에 발생되는 거품저감대책, pp. 35-40 (1994)
3 Wood, I. R., Air Entrainment in Free Surface Flows, IAHR Hydraulic Structure Design Manual, A, A. Balkema, pp. 20-22 (1991)
4 이대수, 강금석, 이해균, 발전소 방류구의 수리학적 거품저감방안 연구(최종보고서), 전력연구원, pp. 15-21 (2002)