• Title/Summary/Keyword: Wastewater Pump

Search Result 70, Processing Time 0.02 seconds

Effect of cake resistance by first-aggregation of in-line injection system (인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향)

  • KIM, Taeyoung;PARK, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

Leakage Control and Application Using the Pressure Reducing Valve (압력제어밸브를 통한 누수량의 추정과 활용)

  • Kim, Shin-Geol;Kim, Youn-Hwan;Kim, Kyoung-Pil;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

Influence of Different Mixing Types on the Removal of Natural Organic Matter in Water Treatment (정수처리시 천연유기물질의 제거에 대한 급속혼화유형의 영향)

  • Kim, Hyun-Chul;Yu, Myong-Jin;Lee, Seock-Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.370-377
    • /
    • 2005
  • Dispersion of coagulant should be completed in a fraction of a second before the metal hydroxide precipitate has form. For the reason so-called pump diffusion flash mixing (PDFM) have been proposed, and PDFM is one of reasonable methods to quickly disperse the hydrolyzing metal salts. In this study, therefore, we attempt to understand the difference of removal characteristics of natural organic matter (NOM) between pump diffusion flash mixing (PDFM) and conventional rapid mixing (CRM) for coagulation in a water treatment system, and to enhance the removal of NOM through the improved mixing process. DOC and turbidity removal by PDFM higher than those by CRM, while SUVA value of water treated by PDFM was high as compared with that by CRM. Hydrophilic NOM was more effectively removed by PDFM than CRM, since charge neutralization effect increased by quick dispersion of coagulant. The DBP formation potentials due to NOM was effectively reduced by the improved mixing (i.e., PDFM) for coagulation and could be controlled through decrease in concentration of precursor rather than reduction of activity with disinfectant.

Design of Multi-Regional Water Supply System Based on the Optimization Technique (최적화 기법을 이용한 광역상수도 관로시스템 설계)

  • Kim, Ju Hwan;Kim, Zong Woo;Park, Jae Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.95-112
    • /
    • 1999
  • In this research, it is proposed that optimization method is introduced and applied to the design of pipeline system in multi-regional water supply project, which has been constructed to settle the regional unbalance problems of available water resources. For the purpose, interface programs are developed to integrate linear programming model and KYPIPE model which is used for optimization and hydraulic analysis, respectively. The developed program is applied to the pipeline system design of multi-regional water supply project. The optimal diameters from the application of linear programming technique are compared with those from conventional method that is time-consuming and tedious trail and error process. Since the conventional design largely depends upon the experience of designers and the results of general hydraulic analysis, it can not be reasonable and consistent. The application of linear programming technique can make it possible to design pipeline system optimally by using same design factors of general hydraulic models. The model can select commercial discrete pipe diameter as optimal size by using pipe length as decision variables. The developed model is applied to Pohang multi-regional water supply system design with two different objective functions, which are initial construction cost and annual cost including electric cost. As results, it is calculated that the initial construction cost of 1,449,740 thousand won is saved and annual cost of 128,951 thousand won is saved for a year within study year. Also, the optimal site of pump station is selected on 5th pipe, which is located between the diverging junction to Kangdong(2) province and the diverging junction to Cheonbuk province. It is explained that pump cost is less than pipe cost in this application case study due to little pump station scale. In the case of water supply with large pump capacity, it is reasonal that the increase of pipe size is more efficient instead the increase of pump station capacity to save annual cost.

  • PDF

Development of the Monitoring System for maintaining On-site Wastewater Treatment Plants (소규모 현장 오수처리시설의 유지관리를 위한 Monitoring System 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.417-420
    • /
    • 2001
  • The monitoring system for maintaining on-site wastewater treatment plants(Biofilter) was developed. Proposed system applied PLC(Programmable Logic Controller) technique. In process of development, the research against the monitoring parameters which will be able to represent condition and operation of the plants was accomplished. These parameters are ORP(Oxidation-Reduction Potential), Water Level, Pump and Power on/off. Also, to measure, collect, transfer and display these parameters, DMU(Data Measurement Unit), MCU(Main Controller Unit) and Display Board were produced.

  • PDF

Removal of Malodorous Gases Emitted from a Wastewater Pumping Stations by Biological Methods (생물학적 방법에 의한 하수 중계펌프장의 악취제거)

  • 류희욱
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.3
    • /
    • pp.265-270
    • /
    • 2004
  • To select a promising technologies for removal of odorous gases emitted from a wastewater pump station, four methods such as activated carbon (A/C) adsorption, chemical absorption (acid and alkali scrubber), and two biofilters (polyurethane (PU) and worm cast) were investigated. The average odor removal efficiencies in the PU biofilter and A/C column was over 98%, but in a worm cast biofilter and chemical absorption were below 60-80%. The removal efficiency of PU biofilter was very stable (about 98-99%) in the range of retention times of 4-36s, and a maximum elimination capacity was $1.6${\times}$10^{ 7}$ $OUm^{-3}$$h^{-1}$ Deodorization costs for an activated carbon adsorption and a biofiltration method were investigated. With increasing odor intensity, the operating cost of the A/C column increased linearly, but the operating cost of the biofilteration increased slightly. The capital cost in a biofilter is about two times higher than that in an A/C column, but the operating cost is very lower than that of in A/C column. In conclusion, the biofiltration was evaluated one of the most promising technologies to control odor in a wastewater pump station.

A Study on the Ozoflotation Process for Drinking Water Treatment (Ozoflotation 공정의 정수처리 적용에 관한 연구)

  • Kang, Tae Hee;Oh, Byung Soo;Lee, Hoon;Byun, Kyu Sik;Kwon, Soon Buhm;Sohn, Byeong Yong;Ahn, Hyo Won;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.528-534
    • /
    • 2005
  • Ozone, a powerful oxidant, is widely used to remove microorganisms, pesticides, taste and odor compounds effectively. Dissolved air flotation (OAF) has been known as an economical process for treating algae and low turbid water quality. An ozoflotation system, combining ozone and OAF processes, has a merit which can operate the ozonation and flotation process simultaneously in a single compartment. This study investigated the application of the ozoflotation process for advanced water treatment by carrying out the pilot-plant experiment. During the test, ozone microbubbles were generated through a OAF pump and many kinds of parameters were evaluated under several conditions, such as raw water flow rate and ozone dose. As a result of the test, the optimum operating conditions of ozoflotation were decided to be 1.2 mg/L ozone dose and about 34 minute Hydraulic retention time (HRT). Finally, it could be demonstrated that the ozoflotation system can effectively improve the drinking water quality.

Effect of Surface Roughness on Performance Analysis of Centrifugal Pump for Wastewater Transport (폐수 이송용 원심펌프의 성능해석에서 표면 거칠기의 영향)

  • Yun, Jeong-Eui;Kim, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.147-153
    • /
    • 2014
  • This study was performed to evaluate the effect of surface roughness on pump performance. To this end this, using commercial codes, ANSYS CFX and BladeGen, we simulated pump performance in terms of efficiency, head and shaft power, both with and without surface roughness. Finally simulation and experiment results were compared for a quantitative analysis. The results of this comparison showed that surface roughness led to an about 7% reduction in pump efficiency.

Experimental and mathematical evaluation of solar powered still equipped by nano plate as the principle stage of zero discharge desalination process

  • Jadidoleslami, Milad;Farahbod, Farshad
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.147-161
    • /
    • 2016
  • To start with, finding a sustainable method to produce sweet water and electricity by using renewable energies is one of the most important issues at this time. So, experimental and theoretical analysis of the performance of a closed solar powered still, which is jointed to photovoltaic cells and vacuum pump and equipped by nano plate, as the principle stage of zero discharge desalination process is investigated in this project. Major goal of this work is to reuse the concentrated brine of the Mobin petrochemical complex in order to produce potable, sweet water from effluent saline wastewater and generating electricity in the same time by using solar energy instead of discharging them to the environment. It is observed the increase in brackish water temperature increases the average daily production of solar desalination still considerably. Therefore, the nano plate and vacuum pump are added to augment the evaporation rate. The insolation rate, evaporation rate, the average brackish temperature, ambient temperature, density are investigated during a year 2013. In addition to obtain the capacity of solar powered still, the highest and lowest amount of water and electricity generation are reported during a twelvemonth (2013). Results indicate the average daily production is increased 16%, which represents 7.78 kW.h energy saving comparing with traditional solar still.