• Title/Summary/Keyword: Wastewater Characteristics

Search Result 1,156, Processing Time 0.023 seconds

Study on Characteristics of Wastewater Flow for Namyangju City (남양주시 하수발생특성 연구)

  • Hwang, Byung-Gi;Lee, Eui-Sang;Kim, Kyung-Won;Son, Jung-Eun
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.2
    • /
    • pp.73-86
    • /
    • 2003
  • In this study, we performed 8 times of water quality sampling and continuous measurement of flow to identify wastewater flow characteristics for wastewater treatment basins of Namyangju city. The field survey has been conducted 6 times in dry weather period and 2 times in wet weather period. Each survey conducted 24-hr water quality sampling in the interval of 2-hr. From the analysis of flow data and water quality data, the following conclusions can be drawn. For Namyangju-1 station, which represents residential and commercial mixed area, flow rises early in the morning before office-going hour and moves up and down within narrow range, and lasted after office-leaving hour, resulting from continuous commercial activity. In case of Namyangju-5 station representing community and Namyangju- 6 station representing residential area, the flow immediately falls down after rising early in the morning and later rises again at the office-leaving hour, and arrives at peak flows around late evening. In the analysis of wastewater characteristics for weekdays and weekends, without landuse types the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period.

Nitrogen removal characteristics of pigment wastewater using PAC-A/O process (PAC-A/O 공정을 이용한 안료폐수의 질소 제거 특성)

  • Jeong, Jongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2018
  • The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading $0.86kgBOD/m^3/day$, mean F/M ratio 0.072~0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3~8.7 and mean temperature $34.1{\sim}44.0^{\circ}C$. The ORP bending point knee was eventually appeared in the ORP -107 mV and $NO_3{^-}-N$ removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and $NO_3{^-}-N$ was 92.3~95.0% and 98.5~99.7%. Denitrification rate was calculated to be 1.581~1.791 mg $NO_3{^-}-N/gMLSS/hr$. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.

Evaluation of influent changing effect on the STP performance using Dr. Wastewater (Dr. Wastewater program의 적용을 통한 하수처리장 운전에 미치는 유입수 변동 영향평가)

  • Kim, Youn Kwon;Kim, Hong Suck;Seo, In Seok;Kim, Byung Goon;Han, In Sun;Kim, Jin Sang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.647-655
    • /
    • 2008
  • Sewer Rehabilitation Project (SRP) is planed, designed and constructed to perform its intended performance as sewerage delivery systems. Recently, a subject of performance evaluation methodology development for SRP has become a great deal of concern among researchers in Korea. From the view point of Sewage Treatment Plant (STP), however, the estimation of improvement efficiency for SRP is in lack of reliability due to the fact that affections for the treatment efficiency and operating condition are not reflected on SRP design and construction. In this study, statistical methodology was used in the analysis of data, which are taken during 1,186 days ($1^{st}$ Jan. 2005 - $31^{th}$ Mar. 2008) from the influent, effluent and operating conditions of full-scale STP($25,000m^3/d$). Then the effect of SRP on the influent characteristics and operating conditions changing was compared and evaluated. Results from the statistical evaluation show that SRP causes characteristic changes in influent and exerts a significant effect especially on the performance of STP.

A study on the characteristics of wastewater flowrate in land-use of Sogwipo-city in Cheju (제주도 서귀포시지역의 용도지역별 하수발생량 특성에 관한 연구)

  • Jeong, Gwang Ok;Ryu, Seong Pil
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.251-262
    • /
    • 2004
  • To identify the characteristics of wastewater flow generated in treatment basins of Seogwipo-city, we selected 3 stations representing the basin and performed 7 times of field survey including 5 times in dry periods and 2 times in wet periods from Feb. 25 to May 27, 2002 for the selected stations. From the analysis of flow data measured for more than 60 days in the interval of 5 minutes and concentration data obtained from laboratory analysis, we can draw several conclusions. First, in the analysis of diurnal variation of wastewater flow for land-use types, we could find the following results: in the residential area, it is observed that wastewater flow rates rise early in the morning for the office-going hour and fall gradually and rise again after the office-leaving hour, showing typical residential wastewater flow pattern, while for the residential and commercial area flow rates rise early in the morning at the office-going hour and move up and down repeatedly within wide range and last till the office-leaving hour, which can be resulted from wastewater that is generated by tourists activated after early in the afternoon, while for the touristy area flow rates rise early in the morning and fall gradually and rise again within wide range. Second, in the analysis of temporal variation of wastewater flow for monthly, it can be observed that in the residential area, in the residential and commercial areas the flow rate of May is higher than that of Feb., March, while for the touristy area flow rate is without monthly because it reflects the movement of population, Third, in wet periods concentration of water-quality item such as SS, BOD, and COD_{cr}$ is high in the beginning of rainfall by first flush, and falls down gradually to reach the steady state, which is the level of wastewater in dry periods after the cease of storm water due to diluting effect resulting from additional runoff water through storm sewers.

Characteristics of Eleclrolytic Treatment of Dye Wastewater (염색폐수의 전해처리 특성)

  • 전법주;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.37-46
    • /
    • 1996
  • In this study, the effect of pH, Temp, dye concentration, distance of electrode, and the potential on the removal efficiency of dye-wastewater using electrochemical reaction were investigated. Optimum conditions for the electrochemical treatment of dye-wastewater were obtained that pH;7, 8V, electrode distance; 1cm and the reaction time for obtaining above 99% removal efficiency were 10 - 40min at each conditions, From this result, we can determine the instantaneous current efficiency and specific energy consumption, and we can provide the effective data for economical treatment of industrial dye-wastewater.

  • PDF

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

The Characteristics of the Ozonation of phenol wastewater by the variation of pH using the continuous PCR and BCR (연속식 PCR과 BCR에서 pH 변화에 따른 페놀 폐수의 오존처리특성에 관한 연구)

  • 안재동;김민수;김용대;최석규
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.74-80
    • /
    • 1997
  • This study was performed to estimate the ozonation characteristics of phenol wastewater with increasing pH in the continuous packed column reactor (PCR) and the bubble column reactor (BCR). Among various influencing factors that affect phenol on decomposition through the ozonation, pH was chosen as reaction parameter. Upon increasing pH from 3 to 9, the phenol removal efficiency in PCR was improved approximately by 17% while in BCR approximately by 19.2%. The improvements in the phenol removal efficiency by increasing pH caused the enhancements in ozone utilization efficiency reaching almost 100% in PCR at pH 9. In conclusions, ozone has latent power for phenol wastewater treatment, and the performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

Performance Anaysis of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant (하수처리장 방류수를 이용한 소수력발전 성능분석)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.494-497
    • /
    • 2012
  • A methodology to predict the output performance of small hydro power using treated effluent in wastewater treatment plant has been studied. Existing plant located Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in wastewater treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed.

  • PDF

A Study on the Wastewater Treatment Characteristics according to Operating Condition of the Indirectly Aerated Fluidized Bed (간접(間接) 포기식 유동상(流動床)의 운전조건(運轉條件) 변화에 따른 처리(處理) 특성(特性)에 관한 연구 -오니전환율 및 산소이용속도를 중심으로-)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.79-86
    • /
    • 1997
  • The characteristics of wastewater treatment according to operating condition of indirectly aerated fluidized bed filled with sand media were studied experimentally, and the obtained results were as follows; 1. During be operated under the BOD loading rate, $4.5kg-BOD/m^3{\cdot}day$, effluent SS according to the increase of recirulation velocities was gradually decreased. 2. According to the increase of media concentration, sludge convertion rate was gradually increased. 3. Under the same BOD loading rate, according to the increase of recirulation velocities, F/M ratio was gradually increased, however, sludge convertion rate was greatly decreased. On the other hand, inffluent BOD concentration has not an important effect. 4. Under the constant recirulation velocities, according to the increase of BOD loading rate, sludge convertion rate was gradually increased. 5. Under the same BOD loading rate, according to the increase of recirulation velocities, oxygen consumpion rate of microorgnism was gradually increased.

  • PDF

Reaction Characteristics and Kinetics for Treatment of Wastewater Containing Phenol (Phenol 함유 폐수의 처리를 위한 반응 특성과 속도론)

  • Kang, Sun-Tae;Kim, Jeong-Mog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.124-130
    • /
    • 1997
  • Wastewater containing phenol was treated using Pseudomonas sp. B3 in continuous reactor, reaction characteristics and kinetics according to variation of volumetric loading rate in continuous reactor were studied. The removal efficiencies of phenol were more than 99% at the whole range of experiment, and those of COD were 97% at the volumetric loading rate, $0.96kg/m^3{\cdot}d$ and 88% at $3.0kg/m^3{\cdot}d$, respectively. Kinetics constants of $q_m$, $K_s$, Y and $K_d$ were obtained 0.901 l/d, 0.620mg/l, 0.659 and 0.219 l/d, respectively. As compared with to constants of standard activated sludge process, these constants were remarkably different because of toxicity and inhibition of phenol to microbes. And also, kinetics constants of oxygen utilization, a, and b, were shown 0.384 kg $O_2/kg$ phenol and 0.029 l/d.

  • PDF