• 제목/요약/키워드: Waste tire

검색결과 158건 처리시간 0.022초

양산시 산업단지에서 측정한 악취물질의 농도 분포 특성 및 대기확산 모델링 (Characteristics of Malodor Pollutants and Their Dispersion Measured in Several Industrial Source Regions in Yangsan)

  • 송상근;손장호;김유근;박흥재
    • 한국환경과학회지
    • /
    • 제18권10호
    • /
    • pp.1103-1114
    • /
    • 2009
  • In this study, the environmental behavior of malodor pollutants (MPs: $H_2S$, $CH_3SH$, DMS, and DMDS) was investigated around areas influenced by strong anthropogenic processes based on observations and modeling study (a CALPUFF dispersion model). The MP emission concentrations were measured from 8 industrial source regions (tire plants (S1-S3), waste water disposal plant (S4), and oil refinery (S5) in an urban center area and paper mill/incineration plant (S6) and livestock feedlots (S7-S8) in Ungsang area) in Yangsan city during a fall period in 2008 (21 October 2008). Overall, the most MPs emitted from the urban center area were found to affect the malodor pollution in their downwind areas during early morning (06:00 LST) and nighttime (18:00 and 21:00 LST), compared with those in the Ungsang area. For malodor intensity, the most MPs in the urban center area (especially S1 and S2) were found to be a significant contributor, whereas $CH_3SH$ and $H_2S$ in the Ungsnag area (especially S6) were the dominant contributor. The model study showed agreement in the spatial distributions of simulated MPs with those of the observations. The largest impact of MPs in the urban center area on the malodor pollution in its residential areas occurred at S1, S2, and S3 sites during nighttime, while that of MPs in the Ungsang area occurred at S6 and S8 sites. This may be caused mainly by the high MP emissions and in part by wind conditions (prevailing northeasterly winds with low wind speeds of 2-3 m/s).

폐타이어 고무분말과 골재를 혼입한 폴리우레탄 복합재료의 감쇠 특성 (Damping Characteristics of Polyurethane Composites Incorporating Recycled Rubber Particles and Aggregates)

  • 박세언;최정일;황재승;이방연
    • 한국건설순환자원학회논문집
    • /
    • 제8권3호
    • /
    • pp.263-268
    • /
    • 2020
  • 이 연구의 목적은 폐타이어 고무분말을 혼입한 폴리우레탄 복합재료와 굵은 골재를 사전채움하고 폴리우레탄을 주입한 폴리우레탄 복합재료의 감쇠성능을 평가하는 것이다. 이를 위하여 총 4 종류의 폴리우레탄 기반 복합재료를 제조하였고, 충격 가진 실험을 실시하였다. 실험을 통하여 시간 영역과 주파수 영역에서의 진동특성을 계측한 후 감쇠비를 계산하였다. 실험 결과, 고무분말을 혼입하여 폴리우레탄의 양이 각각 10.6%와 21.2% 줄어든 실험체들의 감쇠비는 순수한 폴리우레탄 실험체에 비하여 각각 8.4%와 4.6% 낮은 것으로 나타났다. 프리팩트 콘크리트 제조 방법과 유사한 방법으로 제조한 폴리우레탄 복합재료의 감쇠비는 순수 폴리우레탄에 비하여 22% 낮은 것으로 나타났지만 폴리우레탄 혼입량은 50% 감소하였으며, 강성은 25.7배 높은 것으로 나타났다.

염색산업단지 종합폐수처리용 재순환 통합시스템 (Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.837-845
    • /
    • 2017
  • D염색공단의 폴리에스테르 알카리 감량폐수 및 호발폐수가 혼합된 실제 종합염색폐수를 처리하기 위하여 D염색공단의 종합폐수처리장 반송슬러지를 고정한 폐타이어담체를 충전한 재순환 유동상 바이오필터와 소성된 $TiO_2$ 코팅-glass bead를 광촉매담체로 적용한 UV/광촉매반응기를 결합한 재순환 통합시스템을 구축하여 운전하였다. 그 결과로서 재순환 통합시스템의 총 $COD_{cr}$ 제거율과 총 색도 제거율 추이는 각각 약 81% 및 55% 정도를 유지하였다. 이러한 재순환 통합시스템의 총 $COD_{cr}$ 및 총 색도 제거율의 제고효과는 각각 최대 약 7% 및 3%로 평가되었다. 재순환 통합시스템의 유동상 바이오필터 및 광촉매반응공정은 총 제거율에 대한 상대기여도로서 각각 총 $COD_{cr}$ 제거율의 약 94% 및 6%를 처리하고, 총 색도 제거율의 약 86% 및 14%를 처리하였다. 이와 같이 재순환 통합시스템의 광촉매반응공정에서는 총 제거율에 대한 색도 제거율의 상대기여도가 $COD_{cr}$ 제거율의 상대기여도보다 약 2.4배 정도 컸다. 따라서 본 연구의 재순환 통합시스템에서 광촉매반응공정은 $COD_{cr}$ 제거보다 아조결합과 같이 염료에서 색을 나타내는 화학결합을 깨는 역할에 더욱 효율성이 있었다. 또한 본 연구의 재순환 통합시스템에서 각 단위공정들의 $COD_{cr}$ 및 색도 제거율이, 재순환 통합시스템의 총 $COD_{cr}$ 및 색도 제거율에 미치는 영향에 대한 모델식과 대수적 상관관계를 구하고 분석하였다.

통합 하이브리드시스템의 압력강하 거동 및 바이오필터 담체의 미생물 population 분포 (Pressure Drop of Integrated Hybrid System and Microbe-population Distribution of Biofilter-media)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.116-124
    • /
    • 2022
  • 교대로 운전되는 광촉매반응기 공정, 및 바이오필터 공정(전통적 바이오필터(L 반응기)와 두 개의 유닛(unit)을 가지는 개선된 바이오필터시스템(R 반응기))로 구성된 통합처리시스템에서, 에탄올과 황화수소를 동시 함유한 폐가스 처리를 수행하는데 발생하는 공정 당 압력강하(△p)와 바이오필터 공정의 미생물 population 분포를 관찰하였다. 교대로 운전되는 광촉매 반응기의 △p는, 바이오필터의 △p와 비교할 때에 무시할 정도로 작게 관찰되었다. L 반응기의 △p는, 통합처리시스템의 운전 중에 계속 증가하여 4.0~5.0 mmH2O (i.e., 5.0~6.25 mmH2O/m)로 증가하였다. 한편 R 반응기의 경우에서는 L 반응기의 △p의 약 16~20% 이하인 작은 △p를 나타내었다. 본 연구에서 적용한 공극율이 큰 폐타이어 담체 등의 바이오필터 담체 및 R 반응기 설계의 적용이, 목재 칩(wood chip)과 목재 바크(wood bark)의 50 대 50인 혼합물을 바이오필터 담체로 사용한 전통적 바이오필터의 보고된 압력강하 값의 각각 37~50%와 40~53% 만큼 압력강하 저감에 공헌하였다고 분석되었다. 또한 본 연구의 R 반응기 운전에서 압력강하 값이, 공극율이 큰 화산석(scoria)과 compost를 75 대 25로 혼합한 복합 담체를 충전한 전통적 바이오필터의 보고된 압력강하 값보다 약 80%만큼 저감된 결과는 주로 R 반응기 설계의 적용에 기인하였다고 해석되었다. 한편, 통합처리시스템에서 바이오필터 담체의 microbial population 분포로서 L 반응기 및 R 반응기의 담체 내 미생물 콜로니 수 비교에서는 L 반응기가 제일 밑단에서 다른 윗 단의 콜로니 수보다 거의 두 배로 증가하였으나; R 반응기의 경우는 Rdn 반응기와 Rup 반응기 각각의 상단과 하단에서 고르게 분포하였고 L 반응기보다 콜로니 수가 평균적으로 약 50% 정도 더 컸다. 이러한 현상은 R 반응기의 상단과 하단의 함수율이 50-55%의 고른 분포를 보인 것에 기인하였다. 따라서 개선된 바이오필터시스템이 전통적 바이오필터보다 △p와 미생물 population 분포에서 더욱 우수한 특성을 보였다.

DRUM impactor를 이용한 대기 입자상 물질 중 원소성분의 입경분포 특성 : 제주도 고산지역의 2002년 봄철 (3.29-5.30) 측정 연구 (Size Distributions of Trace Elements in Airborn Particulates Collected using Drum impactor at Gosan, Jeju Island : Measurements in Springtime 2002)

  • 한진석;문광주;류성윤;안준영;공부주;홍유덕;김영준
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.555-569
    • /
    • 2004
  • Size -segregated measurements of aerosol composition using 8-stage DRUM impactor are used to determine the transport of natural and anthropogenic aerosols at Gosan site from 29 March to 30 May in 2002. Separation of ambient aerosols by DRUM impactor offers many Advantages over other standard filtration techniques. Some of the most important advantages are the ability to segregate into details by particle tire, to better preserve chemical integrity since the air stream doesn't pars through the deposit, to collect samples as a function of time, and to have a wide variety of impaction surfaces available to match analytical needs. Although the transport of Yellow sand is a well-known phenomenon in springtime, the result of measurement shows that not only soil dust but also anthropogenic aerosols, including sulfur, enriched trace metals such as Pb, Ni, Zn. Cu, Cr, As, Se, Br, are transported to Gosan in springtime. This study combines the size- and time-resolved aerosol composition measurements with isentropic, backward air-mass trajectories in order to identify some potential source regions of anthropogenic aerosols. As a result, during the NYS period, the average concentration of PM$_{10}$ was 46$\mu\textrm{g}$/㎥, Si, Al. S, Fe, Cl, K, Ca were higher than 1,000 ng/㎥ and Ti was about 100 ng/㎥. The concentrations of Zn, Mn, Cu. Pb, Br, Rb, V, Cr, Ni. At, Se ranged between 1 and 70 ng/㎥. More than 50% typical soil elements, tuck as Al, Si, Fe, Cd. Ti, Cr, Cu, Br. were distributed in a coarse particle range(5.0-12${\mu}{\textrm}{m}$). In other hand, anthropogenic pollutants, luck as S, N, Vi, were mainly distributed in a fine particle range (0.09-0.56${\mu}{\textrm}{m}$). During the YS period, PM$_{10}$ increased about 8 times than NYS period, and main soil elements, such as Al, Si, S, K, V, Mn, Fe also doubled in coarse particle range (1.15-12${\mu}{\textrm}{m}$). But Zn, As, Pb, Cu and Se, which distributed in the time aerosols (0.09-0.56${\mu}{\textrm}{m}$), were on the same level with or decreased than NYS period. Finally. except the YS Period, coarse particles (2.5-12${\mu}{\textrm}{m}$) are inferred to be influenced by soil, coal combustion, waste incineration, ferrous and nonferrous sources through similar pathways with Yellow Sand. But fine particles have different sources, such as coal combustion, gasoline vehicle, biomass burning, oil or coal combustion, nonferrous and ferrous metal sources, which are transported from China, Korea peninsula and local sources.ces.

실제 혼합염색폐수의 유동상 시스템을 활용한 미생물처리와 하이브리드 재순환시스템처리 (Treatment of an Authentic Textile-dyeing Wastewater Utilizing a Fluidized Biofilter and Hybrid Recirculating System Composed of the Fluidized Biofilter and a UV/photocatalytic Reactor)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제53권1호
    • /
    • pp.71-77
    • /
    • 2015
  • D염색공단의 폴리에스테르 알카리 감량폐수가 혼합된 실제 혼합염색폐수를 처리하기 위하여 Pseudomonas sp. 및 Bacillus cereus/thuringiensis를 고정한 폐타이어담체를 충전한 유동상 바이오필터를 운전하였다. 또한 유동상 바이오필터와 450 W의 UV/광촉매반응기를 결합한 하이브리드 재순환시스템을 구축하여 stage I에서는 UV/광촉매반응기를 바이패스하고 유동상 바이오필터만을, stage II-i, ii, iii에서는 하이브리드 재순환시스템을 각각 운전하였다. 유동상 바이오필터만을 사용하였을 경우에 $COD_{Cr}$ 및 색도 제거효율은 각각 75~80% 및 67%를 나타내었다. 한편 하이브리드 재순환시스템 운전에서 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 $COD_{Cr}$ 제거율이 20~30%에 달하여 총 $COD_{Cr}$ 제거율은 75%로부터 80~85%까지 제고되었다. 한편 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 색도제거율은 0~5%에 불과하였으나 총 색도제거율은 45~65%로부터 65~70%까지 제고되었다. 색도 제거에서는 $COD_{Cr}$ 제거와 다르게 UV/광촉매산화공정에 의하여 유동상 바이오필터의 효율이 제고되어서 하이브리드 재순환시스템의 시너지효과가 나타났다. 또한 색도제거에서는 $COD_{Cr}$ 제거와 다르게 반송비 증가에 따른 광촉매 비활성화가 관찰되지 않았고, $COD_{Cr}$ 제거에서 반송비 증가에 따른 광촉매 비활성화는 비가역적으로 관찰되었다.

제조공정상 발생하는 비산분진의 화재·폭발 위험성에 대한 열적특성 비교에 관한 연구 (Study on the Thermal Characteristic Comparison of Fire.Explosion Hazard of Fugitive Dust Generated in the Manufacturing Process)

  • Sun, Ko Jae
    • 한국재난정보학회 논문집
    • /
    • 제10권1호
    • /
    • pp.71-83
    • /
    • 2014
  • 본 연구에서는 잠재적인 화재 및 폭발 위험성이 있는 밀가루 제조공정에서의 분진 및 기능성 비누제조공정에서의 살리실산분진, 합판 제조공정에서 목분, 폐타이어 처리공정에서 발생하는 분진들을 채집하여 열적특성을 비교하기 위해 실험을 수행하였다. DSC 실험결과 대상시료 모두 활석의 첨가량이 증가할수록 열 유속은 감소하고 온도는 감소상태인 것으로 분석되었다. 이는 분해속도가 줄어드는 것이고, 위험성이 감소하고 있는 것을 나타내는 것이다. 그러나 대상시료 모두 승온속도가 증가 할수록 흡열개시온도가 낮은 온도 부분으로 이동하고 있으며, 흡열량도 크게 증가하였다. 이는 승온속도가 증가할수록 시료의 분해위험성이 증가하는 것으로 분석되었다. 아울러TGA 실험결과 대상시료 모두 무게감량의 비율은 활석의 양이 증가할수록 전체 무게감량이 줄어들어 열적 안정성을 확보하는 것으로 나타났다. 향후 분진폭발메커니즘의 지속적 연구와 보완이 효과적인 분진폭발예방 대책수립에 기여할 것으로 기대된다.

혐기-무산소-호기 반응조내 질화세균군의 변화 (Changes of Nitrifying Bacterial Populations in Anaerobic-Anoxic-Oxic Reactors)

  • 박종웅;이영옥;고준혁;라원식;임욱민;박지은
    • 대한환경공학회지
    • /
    • 제27권2호
    • /
    • pp.138-144
    • /
    • 2005
  • 본 연구는 질화작용에 관여하는 Nitrosomonas sp. 등의 암모니아산화세균과 Nitrobacter sp. 등 아질산산화세균이 $A^2/O$ Pilot 장치의 혐기조, 무산소조, 호기조에서 어떤 양상으로 변화하는지를 조사하는데 있다. 혼합액의 부유 질화세균군과 폐타이어로 성형 제조된 입상담체에 부착된 질화세균군은 FISH법으로 분석하였다. Pilot 장치의 질산화속도는 $1.97{\sim}2.98mg\;N/g\;MLVSS{\cdot}hr$의 값을 보였다. 각 반응조에서 총 부유 세균수중 암모니아 산화세균군 (NSO로 검출된 세균군)이 차지하는 비율은 호기조 < 무산소조 < 혐기조 순이었으나, 이와 반대로 아질산 산화세균(NIT로 검출된 세균)이 차지하는 비율은 혐기조 < 무산소조 < 호기조 순이었다. 생물막의 두께와 건조밀도 및 담체 무게당 부착된 미생물량은 각각 $180{\sim}188\;{\mu}m$, $38.5{\sim}43.9\;mg/cm^3$, $29.4{\sim}32.5\;mg/g$ 이었고, 담체에 부착된 총세균수 중 질화세균이 차지하는 비율은 NSO(3.2%)와 NIT(2.8%)가 거의 비슷하였으나, 각 반응조에 존재하는 부유성 질화세균, 즉 NSO($22.8{\sim}28.4%$)와 NIT($17{\sim}26%$)에 비해서는 부착성 질산화 세균의 비가 현저히 낮았다.