• Title/Summary/Keyword: Waste factor

Search Result 542, Processing Time 0.026 seconds

Evaluation of COD Solubilization and Reduction of Waste Activated Sludge by pH Control (pH 조절을 통한 폐활성 슬러지의 COD 가용화 및 감량화 평가)

  • Kim, Youn Kwon;Moon, Yong Taik;Kim, Ji Yeon;Seo, In Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.551-558
    • /
    • 2007
  • From the view point of biological wastewater treatment, C/N ratio is one of the most important factor in biological nutrient removal process. However, municipal sewage in Korea is characterized by extremely low content of carbon source and relatively higher portion of N source. Accordingly, it is necessary to dose external carbon source in order to obtain higher degree of carbon source within the process. In this study, the effects of pH pretreatment as an alternative plan for increasing carbon source on the cell disruption and COD solubility of waste activated sludge were conducted under well defined experimental conditions. During 5 hours, the value of COD solubilization rate ($S_R$) at pH 11.5 is approximately 4.4 times higher than the value of $S_R$ at pH 9.5. It is expected that the level of SCOD increased due to the result from cell disruption. However, VSS/TSS ratio was not significantly changed after 5 hours. As Alkalinity changes gradually from less than 15, 30 and 60 meq NaOH/L, average RBCOD/SCOD fraction showed 34, 36 and 45%,respectively.

A Study on the Waste Volume Calculation for Efficient Volume Monitoring in a Landfill Facility (매립장의 효율적인 체적 모니터링을 위한 체적 계산 방법에 대한 연구)

  • Lee, Young Dae;Cho, Sung Youn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.153-159
    • /
    • 2012
  • For the enhancement of civilization of a city, the standard landfill facility is needed for the efficient, and computerized management. In this paper, we proposed the waste volume calculation method using the point cloud of the surface of three dimensional object based on stereo camera measurement. This computes the quantity of waste volume for continuos monitoring. It helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, it can be used for the basis of general algorithm of three dimensional object.

Comparison of Land Farming and Chemical Oxidation based on Environmental Footprint Analysis (환경적 footprint 분석을 통한 토양경작법과 화학적산화법의 비교)

  • Kim, Yun-Soo;Lim, Hyung-Suk;Park, Jae-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.3
    • /
    • pp.7-14
    • /
    • 2015
  • In this study, land farming and chemical oxidation of a diesel-contaminated site is compared to evaluate the environmental impact during soil remediation using the Spreadsheet for Environmental Footprint Analysis by U.S. EPA. Each remediation process is divided into four phases, consisting of soil excavation, backfill and transportation (Phase 0), construction of remediation facility (Phase 1), remediation operation (Phase 2), and restoration of site and waste disposal (Phase 3). Environmental footprints, such as material use, energy consumption, air emission, water use and waste generation, are analyzed to find the way to minimize the environmental impact. In material use and waste generation, land farming has more environmental effect than chemical oxidation due to the concrete and backfill material used to construct land farming facility in Phase 1. Also, in energy use, land farming use about six times more energy than chemical oxidation because of cement production and fuel use of heavy machinery, such as backhoe and truck. However, carbon dioxide, commonly considered as important factor of environmental impact due to global warming effect, is emitted more in chemical oxidation because of hydrogen peroxide production. Water use of chemical oxidation is also 2.1 times higher than land farming.

Performance Assessment of PVA Geotextile/HDPE Geomembrane Composites

  • Jeon, Han-Yong;Hong, Sang-Jin;Lyoo, Won-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.1
    • /
    • pp.37-46
    • /
    • 2005
  • PVA geotextile/HDPE geomembrane composites were made to examine the waste landfill related properties. Tensile properties, tear and bursting strengths, AOS(apparent opening size) and permittivity of PVA geotextiles were evaluated, respectively. Ultraviolet stability and chemical resistance to the leachate was evaluated also. Friction property and creep deformation were tested at various loading condition. From this, it was seen that PVA geotextile/HDPE geomembrane composites have more excellent properties than the typically used polypropylene and polyester geotextiles in waste landfill. Finally, creep deformation behaviours of PVA geotextile/HDPE geomembrane composites were more stable than polypropylene and polyester geotextiles through the reduction factor analysis.

  • PDF

Environmental Consciousness and Environmental Preservation Behavior of Textile Producers (섬유제품 생산자의 환경의식과 환경보전행동)

  • 김용숙
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.5
    • /
    • pp.183-196
    • /
    • 1996
  • The purposes of this study were to review the effects of textiles production on the environment, and to investigate the environmental consciousness and environmental preservation behavior of textile producers. This study was conducted by reference analysis and empirical research. To develope theoretical framework of dimensions of environmental behavior, references concerned were analyzed. And for empirical study, researcher developed a questionnaire based on the free writing by producers and references. The questionnaire included problems about environmental consciousness, environmental behavior, demographic variables, and environmental variables. 135 questionnaires were used for final data analysis. ANOVA and factor analysis were used. The results were as follows: First, the level of global environmental problem consciousness was relatively high. The conscious level of water pollution caused by the waste water from textile mills was the highest, and that of desertation of mountain caused by timber cutting was the lowest. The effects of textile dyers and finishers on the environment were the highest, and that of designers were the lowest. Second, the results of reference analysis showed that the dimensions of textile producers environmental behavior were resource and energy saving, solid waste reduction, and green product production. And the results of empirical study were resource and energy saving, resource reuse or recycling, solid waste reduction, and green product production, and total variances was 62.3%. The practice was the lowest. Third, global environment problem consciousness, environment problem consciousness caused by the textile life-cycle concerned, and clothing seperate-collection or not at residing place were effective on environmental behavior, and 52.45% of environmental behavior was explained with above variables.

  • PDF

Disinfection Efficiency of the Waste Stabilization Ponds Coupled with Aquatic Plant Ponds (산화지와 수생식물 처리지를 결합한 통합 처리 시스템의 살균효율에 관한 연구)

  • Kim, Youngchul;Jeong, Ha-Young;Lee, Rae-Bum;Lim, Gyeongeun
    • Journal of Wetlands Research
    • /
    • v.4 no.2
    • /
    • pp.23-41
    • /
    • 2002
  • In this paper, changes of the coliform bacteria were investigated when aquatic plant pond was used for separating algal particles from waste stabilization ponds(WSPs). Three different types of integrated natural systems were operated. It was found that there were no significant interferences for the disinfection efficiency of two integrated systems (WSPs coupled with water hyacinth ponds) used for treating domestic sewage and upgrading the secondary effluent as well. However, when constructed wetland (CW) was combined with the shallow algal ponds and used for the secondary effluent, it seriously interfered with the disinfection efficiency due to the regrowth and/or after-growth of the coliform bacteria, which can readily metabolize the amino acids and sugars leached from plants. In order to find out the primary disinfection parameters, several sets of the batch test were run. It was found that sunlight is the most predominant factor for the coliform decay. During the night, algal toxicity partly supports the decay but during the day, deteriorates it by attenuating the sunlight. The pH in the range of 4 to 10 did not affect the decay in the dark.

  • PDF

On the use of flyash-lime-gypsum (FaLG) bricks in the storage facilities for low level nuclear waste

  • Sidhu, Baltej Singh;Dhaliwal, A.S.;Kahlon, K.S.;Singh, Suhkpal
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.674-680
    • /
    • 2022
  • In the present study, radiation shielding and protection ability of prepared Flyash-lime-Gypsum (FaLG) bricks has been studied in terms of energy exposure build up factors and dose parameters. The energy exposure build up factors of Flyash-lime-Gypsum (FaLG) bricks have been calculated for the energy range of 0.015 MeV-15 MeV and for penetration depth upto 40 mfp directly using a new and simplified Piecewise Linear Spline Interpolation Method (PLSIM). In this new method, the calculations of G.P fitting parameters are not required. The verification and accuracy of this new method has been checked by comparing the results of exposure build up factor for NBS concrete calculated using present method with the results obtained by using G.P fitting method. Further, the relative dose distribution and reduced exposure dose rate for various radioactive isotopes without any shielding material and with Flyash-lime-Gypsum (FaLG) bricks have been calculated in the energy range of 59.59-1332 keV. On the basis of the obtained results, it has been reported that the prepared Flyash-lime-Gypsum (FaLG) bricks possess satisfactory radiation shielding properties and can be used as environmentally safe storage facilities for low level nuclear waste.

A Study on the Optimization of Power Transformer in Apartment Housing (아파트의 동력변압기 용량 최적화 연구)

  • 이기홍;성세진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.78-83
    • /
    • 2001
  • To establish the optimized capacity of power transformer, this paper proposed the total demand factor of power supply facility. For this purpose, it was measured and analysed the operating pattern of power supply acility Installed in the apartment. As a result, it is found that the demand factor of each facility is following that : i) In case of [Xlwer water suwly facility ; 47[%], ii) In case of waste water facility ; 44[%]. Also, it was analysed that the optimized total demand factor of power load is proper 42[%1 than 52[%] to lead the efficiency operation.ration.

  • PDF

Disposal Process Improvement of Construction Waste through Identifying Factors Obstructing Reduction and Recycle of Construction Wastes (주요 건설폐기물의 재활용 저해요인 도출을 통한 현장 건설폐기물 처리 프로세스 개선 방안)

  • Kim, Jae-Moon;Kim, Jee-Hye;Cha, Hee-Sung;Shin, Dong-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.1
    • /
    • pp.77-86
    • /
    • 2008
  • On account of increasing interest of substantiality in these day, it is needed to make an effort to establish an environmentally sustainable production system for the construction works. Although practical affairs and researches are in progress to reduce and recycle construction wastes, as a result of a research, there are still obstructive factors on waste reduction and recycling which they don't interact efficiently between waste disposal process of the construction area and waste disposal company. As a plan to revitalize reduction and recycling of construction wastes, this research focuses on finding obstructive factors and giving solutions to reduce and recycle construction wastes which comes from construction process and construction industries. To meet the needs of the research, firstly relatively significant construction wastes (concrete, soil, brick, block, asphalt, plastic, lumber) were identified. On site level interviews with management of disposal companies and construction sites were conducted as well, focusing on typical waste disposal process. Throughout this interviews, obstructive factors were conducted. A result of the research, the authors suggest an improved approach on disposal and recycling for construction waste by prioritizing the identified factors and ranking the importance level of each factor. And, by identifying factors obstructing reduction and recycle of construction wastes, this research suggests improved disposal process of construction waste.

Biological Hydrogen Production from Mixed Organic Waste of Food and Activated Sludge by Pre-treatment (음식물쓰레기와 전처리한 폐활성슬러지의 혼합비율에 따른 생물학적 수소생산)

  • Lee, Jun-Cheol;Kim, Jae-Hyung;Choi, Kwang-Keun;Pak, Dae-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1044-1050
    • /
    • 2007
  • In this study, Bio-hydrogen is produced from organic waste mixtures containing food waste and waste activated sludge (WAS). The effects of different operational factor on hydrogen production, including various solubilization methods for pretreatments of WAS, pH and different ratios of food waste and WAS, were investigated. The highest hydrogen production values are obtained as 4.3 mL $H_2/g$ $VS_{consumed}$ in the case of applying the mixed pre-treatments of alkali and ultrasonic. The pH value in bio-reactor increased from 4 to 8 after the ultrasonic treatment with alkali and the hydrogen yield touched its highest value in the pH range of 5.0 to 5.5. Similarly, the hydrogen production reached the level of 13.8 mL $H_2/g$ $VS_{consumed}$ using the same pre-treatment method from the mixture of food waste and WAS. The ratio of 2 : 1 produced a maximum amount of hydrogen of 5.0 L $H_2/L/d$. The amount of volatile fatty acids(VFAs) including acetate, propionate and butyrate, were also varied considerably. Propionate decreased consistently with rising of hydrogen while butyrate comparing to acetate relatively increased in the effluent.