• Title/Summary/Keyword: Waste activated sludge(WAS)

Search Result 129, Processing Time 0.043 seconds

Application of a Thermophilic Aerobic Digestion Process to Industrial Waste Activated Sludge Treatment

  • Kim, Young-Kee;Eom, Yong-Suk;Oh, Byung-Keun;Lee, Won-Hong;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.570-576
    • /
    • 2001
  • Thermophilic aerobic bacteria were applied in the degradation of industrial waste activated sludge (WAS) on a laboratory scale expreiment. The performance of digestion was estimated by measuring the reduction of total suspended solids (TSS), dissolved organic carbon (DOC), and total organic carbon (TOC). Among three strains of Bacillus stearothermophilus and three strains of Thermus species, B. stearothemophilus ATCC 31197 showed the best overall efficiency level for the degradation of industrial WAS, which was collected from a wastewater treatment plant in an oil refinery factory. Industrial WAS coul be successfully detraded in a batch digestion with ATCC 31197. The stability of the digestion process with ATCC 31197 was successfully verified by semi-continuous (fill-and-draw) digestion experiment. From the results of this study, it was shown that the thermophilic aerobic digestion process with ATCC 31197 could efficiently be applied to the degradation of industrial WAS.

  • PDF

Study on the Livestock Waste Water Treatment by the Modified Activated-Sludge Process and Sawdust-Soil Filter Method (變形된 活性汚泥法과 톱밥 土壤濾過法을 利用한 畜産廢水處理에 關한 硏究)

  • Jeon, Byoung-Soo;Kwag, Chung-Hoon;Thak, Tae-Young
    • Journal of Animal Environmental Science
    • /
    • v.1 no.1
    • /
    • pp.77-82
    • /
    • 1995
  • In order to investigate the purification effects of livestock waste water, Modified Activated-Sludge Process(MASP) containing marine silica and volcanic ash-rock as the contact media and Sawdust-Soil Filter Method were used. The results obtained are as follows: 1. MASP which treated two metric tons' livestock waste water a day decreased BOD by 97.5% from 4,400.0mg/I to 108.8mg/I and SS by 98.0% from 5,335.0mg/I to 111.0mg/I. 2. MASP decreased BOD by 93.9% from 2,549.1mg/I to 156.6mg/I and SS by 96.3% from 3,521.9mg/I to 132.0mg/I when ten metric ton's livestock waste water was treated a day. 3. BOD and SS were decreased by 83.4% from 45.1mg/I to 7.5mg/I and by 83.4% from 47.5mg/I to 7.9mg/I when the supernatant layer treated by MASP was purified by Sawdust-Soil Filter Method.

  • PDF

Change in the Characteristics of Waste Activated Sludge after Pretreatment of Grinding, Freezing and Thawing (분쇄, 동결, 해동 등 전처리에 의한 하수슬러지의 성상 변화)

  • Seon, Yong-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.93-100
    • /
    • 2010
  • In this study, ways to help anaerobic digestion were studied and waste activated sludge were pretreated by grinding, thawing after freezing and grinding after freezing. The volumes of grinding sludge, thawing after freezing and grinding after freezing were decreased 2.08 times, 3.37 times, 3.54 times compared to the volume of sludge respectively and the larger decline in the sludge has been grinding after freezing, thawing after freezing, and grinding. In addition, when the concentrations of SCOD, SBOD and protein were compared, the concentration of freezing sludge was higher than others and the grinding after freezing method seems to be the highest concentration. When the TS, VS removal rates were compared, thawing after freezing method seems to be higher than others method. From these results, grinding after freezing method is very effective for the pretreatment of sludge and it can be expected grinding after freezing method can be an alternative method for prohibiting ocean dumping of sludge after 2012.

Kinetic Evaluation of Methane Fermentation of Thermally Disintegrated Wastewater Sludge (열처리한 하수슬러지 메탄발효의 동력학적 해석)

  • Park, Ki Young;Lee, Jae Woo;Chung, Tai Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.927-933
    • /
    • 2007
  • Waste activated sludge (WAS) was thermally pretreated to enhance hydrolysis and ultimately methane yield. Batch and semi-continuous anaerobic digestion were conducted to evaluate the performance of methane fermentation of the hydrolyzed sludge and to investigate the kinetics of sludge fermentation. Thermal pretreatment remarkably enhanced digestion performances particularly the methane fermentation with three times more methane production than before the pretreatment. Gas production and kinetic parameters in the semi-continuous anaerobic digestion were estimated using Chen Hashimoto model. The model simulation fitted well the experimental results and the model was shown to be suitable for evaluating the effects of disintegration of WAS in anaerobic digestion. Three parameters ($B_o$, K, and ${\mu}_m$) determined by model simulation were $0.0807L-CH_4/g-VS$, 0.453 and $0.154d^{-1}$ for control sludge, and $0.253L-CH_4/g-VS$, 0.835 and $0.218d^{-1}$ for thermally pretreated sludge, respectively.

Treatment of milking parlor wastewater containing tetracycline by magnetic activated sludge and contact oxidation process

  • Gaowa, Gaowa;Sakai, Yasuzo;Xie, Xiaonan;Saha, Mihir Lal;Ihara, Ikko
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.32-36
    • /
    • 2021
  • Milking parlor wastewater contains not only high concentrations of organic compounds, but often animal antibiotics. To discharge the antibiotics to public water area cause problem of antibiotics resistant bacteria. Magnetic separation was applied into improvement of milking parlor wastewater treatment process. A new process, composed of a magnetic activated sludge (MAS) process and a contact oxidation (CO) process, was proposed in this study. This process was evaluated by the simulated milking parlor wastewater (4500 mg/L CODCr and 10 mg/L tetracycline) using a bench scale experimental setup. As a result, the process was able to removed 97% CODCr as well as 94% tetracycline. The MLVSS (mixed liquor volatile suspended solids) concentration of MAS was maintained at 12000 mg/L without excess sludge drawing. This process was considered to be useful as treatment process for milking parlor wastewater in which waste-milk including antibiotics is often discharged.

Impact of Irradiation Time on the Hydrolysis of Waste Activated Sludge by the Dielectric Heating of Microwave

  • Byun, Imgyu;Lee, Jaeho;Lim, Jisung;Lee, Jeongmin;Park, Taejoo
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The effects of initial solid concentration and microwave irradiation (MWI) time on the hydrolysis of waste activated sludge (WAS) were investigated. MWI time strongly influenced WAS hydrolysis for all initial solid concentrations of 8.20, 31.51, and 52.88 g VSS/L. For all WAS, the volatile suspended solids (VSS) solubilization degree ranged from 35.6% to 38.4% during a total MWI time of 10 min. Soluble chemical oxygen demand (SCOD) concentration increased at a rate proportional to the decrease of VSS during the MWI. However, the clearly different VSS solubilization patterns that were observed during the MWI were explained by the 2-step hydrolysis of WAS, consisting of the initial disintegration of the easily degradable part of the sludge, followed by the subsequent disintegration of the hardly degradable part of the sludge. WAS hydrolysis rates for 3 to 6 min of MWI were significantly lower than those for less than 3 min, or more than 6 min. From these results, 3 min MWI time and WAS of 31.51 g VSS/L (centrifugal thickener WAS) showed the most efficient hydrolysis of WAS at 36.0%. The profiles of total nitrogen (T-N) concentrations corresponded well to the SCOD increases in terms of the empirical formula of bacterial cell mass ($C_5H_7O_2N$). The negligible T-N increase and pH decrease during WAS hydrolysis by MWI will allow the application of this process to subsequent biological processes, such as anaerobic digestion.

Biosorption and Flotation of Lead and Chromium using Waste Activated Sludge (폐 활성슬러지를 이용한 납과 크롬의 생체흡착 및 부상)

  • Lee, Chang-Han
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.444-450
    • /
    • 2009
  • We have investigated biosorption kinetics and equilibrium of $Pb^2+$ and $Cr^2+$ using waste sludge, and separation efficiency of waste sludge by dissolved air flotation was evaluated in the various A/S ratio. The biosorption capacity and contact time were shown as a simulation of biosorption equilibrium and kinetics models. Biosorption equilibrium of the $Pb^2+$ and $Cr^2+$ onto the waste sludge could be fitted by the Langmuir, Freundlich, Redlich-Peterson, and Koble-Corrigan equation. The kinetics could be fitted by a pseudo-second-order rate equation more than a pseudo-first-order rate equation. The separation efficiency of waste sludge using DAF was kept above 90%.

The evaluation of T-P removal and dewaterability under the operation change in KIDEA process (-기술정보- 연속유입 KIDEA에서 공정변화에 따른 인제거 및 탈수 함수율 상관관계)

  • Yeon, seung jun;Her, hee seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.179-182
    • /
    • 2008
  • The KIDEA process, occurred in single reactor, is operated by three consequential steps, i.e., aerobic, settling, and discharge while introducing wastewater into the bottom of reactor continuously. It could accomplish biological oxidation (BOD), nitrification, denitrification (T-N), phosphate removal (T-P), and solid separation (SS) through the operational mode mentioned. Especially, this system has removed the T-P by wasting certain amount of sludge at the end of aeration phase during 5~10 minutes and not returned the activated sludge into the reactor, that is, no RAS (Return Activated Sludge). All running mode and instrumentation were controlled by the PLC equipment automatically. In this study, therefore, we have evaluated T-P removal efficiency and moisture content (MC) performance under the different excess sludge wasting mode. T-P track study and MC with TS concentration were analyzed during aerobic and settling phase. It has revealed that there was no significant difference of released T-P concentration between the first case which waste the sludge at the end of aerobic phase (0.2mg/L) and the second case which waste the sludge at 40 min of settling phase (0.25mg/L). Also, dewatering duration and MC have decreased 1.7% when TS concentration was increased from 0.31% to 0.5% during aerobic condition. Hence, it has concluded the system performance was less influenced by the operation time change of PLC program.

A Study on Volume Reduction of Waste Sludge by Aerobic Thermophilic Bacteria (호기성 호열미생물에 의한 하수슬러지 감량화 효율에 관한 연구)

  • Bae, Yoon-Sun;Kim, Soon-Young;Nam, Duck-Hyun;Park, Chul-Hwi;Kim, Jin-Su;Takada, Kazu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.497-505
    • /
    • 2005
  • Domestic Sewage Treatment Plants are mostly based on biological treatment, in which large amounts of excess sludge are generated and occupy about 40 ~ 60% of the total sewage treatment costs. Several methods for sludge treatment has been so far reported as upgrading biodegradation of sludge; heat treatment, chemical treatment, including thermo-alkali and ozone, mechanical treatment including ultrasonic pulverization. But, it has a limitation in case of reducing the amount of excess sludge which are already producted. In this study, application of excess sludge reduction process using thermophilic aerobic bacteria for activated sludge was examined. The research was carried out two different stage. one for a biological wastewater treatment and the other for a thermophilic aerobic solubilization of the waste sludge. A portion of excess sludge from the wastewater treatment step was into the thermophilic aerobic sludge solubilization reactor, in which the injected sludge was solubilized by thermophilic aerobic bacteria. The solubilized sludge was returned to the aeration tank in the wastewater treatment step for its further degradation. Sludge solubilization reactor was operated at $63{\pm}2^{\circ}C$ with hydraulic retention time(HRT) of 1.5 ~ 1.7 day. Control group was operated with activated sludge process(AS) and experiment group was operated with three conditions(RUN 1, RUN 2, RUN3). RUN 1 was operated with AS without sludge solubilization reactor. RUN 2 were operated with AS with sludge solubilization reactor to examine correlation between sludge circulation ratio and sludge reduction ratio by setting up sludge circulation ratio to 3. RUN 3 was operated with sludge circulation ratio of 3 and MLSS concentration of 1,700~2,000mg/L to examine optimum operation condition. The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge solubilization ratio and sludge reduction ratio were 53. 7%, 95.2% respectively. After steady state operation, average concentration of TBOD, SBOD, $TCOD_{Cr}$, $SCOD_{Cr}$, TSS, VSS, T-N, T-P of effluent were 4.5, 1.7, 27 .8, 13.8, 8.1, 6.2, 15.1, 1.8mg/L in the control group and were 5.6, 2.0, 28.6, 19.1, 9.7, 7.2, 16.1, 2.0mg/L in the experimental group respectively. They were appropriate to effluent standard of Sewage Treatment Plants.

Sludge Thickening Performance of the Filtration Bio-reactor Equipped with Shadow Mask Filter Module (Shadow mask 여과 모듈을 이용한 슬러지 농축 특성)

  • Jung, Yong-Jun;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • In order to recycle the waste material and to develop the thickening unit of waste activated sludge from wastewater treatment facilities, the filtration bio-reactor equipped with a shadow mask filter module was employed for this work from which the operating properties and parameters were drawn. The sludge thickening and filtration unit is made of cylindrical acryl tank(12cm i.d. ${\times}$ 58cm height: working volume of 6L), where the flat-sheet type of shadow mask filter module(pore size: 220~250um, opening area: 34.8~39.6%) was installed and the effluent was withdrawn from the effluent port at the lowest point of the reactor, and the filtration was performed only by the hydraulic pressure. For evaluating the operating performance of this reactor, some parameters such as the solid-liquid separation of different biomass concentrations, the water quality of filtrate, the aeration cleaning time and the cleaning effect were investigated. Depending on the MLSS concentrations, the different time to withdraw 3L of filtrate was required in which the longer filtration time was necessary for the higher MLSS concentrations caused by the thicker formation of cake layer: 40 minutes for 5,000 mg/L, 70 minutes for 10,000 mg/L and 100 minutes for 15,000 mg/L, where the concentrations of SS were 8.9, 6.7 and 6.5 mg/L, respectively. Under the same operating conditions (the intensity of aeration cleaning: 80 L/min, MLSS: 10,000 mg/L), the proper aeration cleaning time was revealed 30 seconds, and the stable formation of cake layer was in the range of 10 to 15 minutes. Therefore, the shadow mask considered as a waste material can be of use as a filter material for the sludge thickening system.