• Title/Summary/Keyword: Washing System

Search Result 487, Processing Time 0.03 seconds

A Study on the Improvement Strategy of Reuse and Recycling of Home Appliances Waste (폐가전제품의 재이용 및 재활용 활성화 방안에 관한 연구)

  • Park, Chan-Hyuk;Chung, Jae-Chun;Lee, Jae-Woong;Kim, Young-Jun;Choi, Suk-soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.74-85
    • /
    • 2003
  • The purpose of this study is to investigate present situation of recovery and treatment of waste home appliances, and to supply basic data for active reuse and recycling of waste home appliances. Among waste home appliances, refrigerator comprise 30.7%, television 37.8%, washing machine 22.9% and air conditioner 0.3%. Local government collected 46.2% of waste home appliances, producer and agent collected 49.7%, recycling center 4.1%. Seventeen percentage of waste home appliances are reused, 65% are recycled, and 18% are landfilled or incinerated. To improve the recycling activity of waste of home appliances, it is important to establish private reuse and recycling organization. It is also necessary to improve waste deposit and refund system for efficient recycling by decent financial support. Extension of a term of usage is another method to minimize waste home appliances. Finally, intensive education for consumer is necessary for waste minimization. Some portion of recycling and treatment cost can be allocated to the local government and large private business can shred and recycle waste home appliances.

  • PDF

Outbreak Pattern Forecasting of Food-borne Disease in Group Food Services in Korea (미래 집단급식 식중독 발생 양상 예측)

  • Jo, Seo-Hee;Kim, Cho-Il;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.1
    • /
    • pp.19-26
    • /
    • 2009
  • This study was undertaken to analyze the hygienic problems of group food services and to predict the outbreak patterns of future food-borne diseases. A delphi survey with 20 experts identified the main causes of food-borne outbreaks in group food services as improper hygienic management of raw food materials, washing of worker's hands, dividing the spaces and unsanitary retail storage. Vibrio parahaemolyticus, Escherichia coli (EPEC), non-typhoid Salmonella serotypes, Staphylococcus aureus, Escherichia coli (ETEC), norovirus, and the hepatitis A virus all have potential to cause outbreaks of food-borne disease. We analyzed the daily food use and the possibility of food-borne outbreaks in school food services for fruits, milk, fish, pork, eggs, and meat as raw food materials, and bibimbab, soybean sprouts muchim, spinach namul, cucumber sengchae, jabchae, and pork bulgogi as prepared food items. Frozen (${\leq}\;-20^{\circ}C$) and refrigerated ($0{\sim}10^{\circ}C$) processed foods are popular items in group food services. Their storage, heating, and chemical sanitization methods are potential sources of food disease outbreaks. Our results can be applied to a well-organized hygiene control system and can be used to develop menus for preventing food-borne outbreaks.

Cr(VI) Removal from Artificial Groundwater by Granular Activated Carbon and Regeneration of the Spent Carbon (입상활성탄을 이용한 인공 조제 지하수내의 Cr(VI) 제거와 그 활성탄의 재생)

  • Ihnsup Han
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.11-31
    • /
    • 1999
  • Removal of hexavalent chromium from artificial groundwater (AGW) by granular activated carbon (GAC) was investigated in batch and continuous-flow column studies. Experimental parameters that were examined included solution pH, presence of dissolved oxygen (DO), and GAC pretreatment with Fe(II). As the solution pH increased from 4 to 7.5, the amount of Cr(VI) removed by both GACs decreased significantly. Exclusion of DO from the experimental systems resulted in greater removal of Cr(VI) from solution, possibly as a result of reduction to Cr(III). However, pretreatment of the GAC with a reductant (Fe(II)) did not improve Cr(VI) removal. Equilibration With 0.01 M $K_2$$HPO_4$[to extract adsorbed Cr(VI)] followed by a wash with 0.02 N $K_2$$HPO_4$[to remove precipitated/sorbed Cr(III)] proved to be a viable approach for the regeneration of carbons whose Cr(VI) removal capacities had been exhausted. The performance of the regenerated carbons exceeded that of the virgin carbons, primarily because of the favorable adsorption of Cr(VI) at lower pH values and the reduction of Cr(VI) to Cr(III), The presence of Cr(III) in acid wash solutions provides direct evidence that Cr(VI) is reduced to Cr(III) in GAC systems under relatively acidic conditions. GAC performance over five complete cycles was consistently high, which suggests that such a system will be able to function over many operation cycles without deleterious effects.

  • PDF

Identifying Characteristics of Incidents at Hazardous Material Facilities

  • Kim, Geun-Young;Kim, Sang-Won;Won, Jai-Mu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.51-56
    • /
    • 2009
  • Safety and quality assessment systems are very important in manufacture, storage, transportation, and handling of hazardous materials(hazmat) to prevent hazmat disasters. At present, hazardous materials exist everywhere in our daily lives with various forms of plastics, household products of cleaning and washing detergents, fertilizers or petroleum-related products. However, hazardous materials are dangerous substances when they are released to human or environment. Hazardous materials become very widely used substances in the age of oil-based industrial economy. The Korean Ministry of Environment (KMOE) describes about one hundred thousand types of chemicals are produced and used worldwide. Over four hundred new chemicals are introduced in every year. A crucial question for the Korean hazardous material management may have been raised: Will you be safe from hazardous material incidents? The gas leak disaster at Union Carbide's Bhopal, India in 1984 that made over 6,400 people killed and 30,000 to 40,000 people seriously injured is the representative case for the safety of hazmat. Korea becomes vulnerable to hazmat disaster due to the development of high-tech industry. Thus, the risk assessment system is required to Korea for transferring abandoned hazmat management systems to self-correcting safety systems. This research analyzed characteristics of various hazmat incidents applying statistical analysis methods including frequency analysis or analysis of category data to hazmat incidents for ten years. All of three analyses of category data indicate the significance of causality between hazmat incident site groups and seasons, regional groups, and incident casualty groups.

Filter Media Specifications for Low Impact Development: A Review of Current Guidelines and Applications (LID 시설 여재에 관한 기술지침 및 적용에 관한 고찰)

  • Guerra, Heidi B.;Kim, Lee-Hyung;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.321-333
    • /
    • 2019
  • A primary aspect of low impact development (LID) design that affects performance efficiency, maintenance frequency, and lifespan of the facility is the type of filter media as well as the arrangement or media profile. Several LID guidelines providing media specifications are currently available and numerous studies have been published presenting the effectiveness of these systems. While some results are similar and consistent, some of them still varies and only a few focuses on the effect of filter media type and arrangement on system performance. This creates a certain level of uncertainty when it comes to filter media selection and design. In this review, a synthesis of filter media specifications from several LID design guidelines are presented and relevant results from different laboratory and field studies are highlighted. The LID systems are first classified as infiltration or non-infiltration structures, and vegetated or non-vegetated structures. Typical profiles of the media according to classification are shown including the different layers, materials, and depth. In addition, results from previous studies regarding the effect of filter media characteristics on hydraulic and hydrologic functions as well as pollutant removal are compared. Other considerations such as organic media leaching, clogging, media washing, and handling during construction were also briefly discussed. This review aims to provide a general guideline that can contribute to proper media selection and design for structural LIDs. In addition, it also identifies opportunities for future research.

Usefulness of Automated PCR Test for the Detection of Mycobacterium Tuberculosis in Fresh Biopsy Tissues (신선조직 검체에서 결핵균 검출을 위한 자동화 중합효소연쇄반응 검사의 유용성)

  • Choi, Woo Soon;Shin, So Young;Kim, Jong Ok;Kim, Myung Sook;Lee, Hye Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • Background: Although there have been several studies regarding the clinical value of an automated TB-PCR study using sputum, bronchial washing, and other body fluid samples for the detection of pulmonary tuberculosis, there are only a few reports on the use of fresh tissue samples. Materials and methods: The acid-fast bacilli stain(AFB), tuberculosis culture, automated TB-PCR study, and histopathology examination were performed in 42 fresh tissue samples. Results: Among the 42 cases, 18 cases were diagnosed with tuberculosis based on the clinical findings. Sixteen of the 18 cases were TB-PCR positive and of these 16 cases, only 2 cases were positive in the AFB stain or culture study. However, all 18 cases showed the histopathology findings of chronic granulomatous inflammation that was compatible with tuberculosis. Based on the clinical findings, the sensitivity, specificity, positive predictability, and negative predictability of the automated TB-PCR study were 88.9%, 100%, 100%, and 92.3% respectively. Conclusion: An automated TB-PCR assay is an important diagnostic tool for diagnosing tuberculosis in fresh tissue samples.

A Study on the Effectiveness of Remanufacturing Technology for the Catalyzed Diesel Particulate Filter-trap(DPF) Deactivated by Diesel Exhaust Gas (촉매가 담지된 사용후 경유차 매연저감장치 DPF의 재제조 효과에 관한연구)

  • Choi, Kang-Yong;Park, Hea-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.957-964
    • /
    • 2010
  • The deactivated catalyzed diesel particulate filter-trap (DPF) was remanufactured by ultrasonic wave treatment with various prepared solutions, followed by active component re-impregnation, and the emission control performance and surface properties of remanufactured DPF were studied at various remanufacturing conditions. The proper ultrasonic wave cleaning time at various prepared solutions and optimal re-impregnation amounts of active component for the best emission control performance of DPF were investigated and its performance tests were also carried out with various temperatures for the conversions of CO, THC (total hydrocarbon) and PM (particulate matter) by catalytic reaction test unit using bypass gas from the diesel engine dynamo system. It was found that the emission control performance of DPF remanufactured with the high-temperature air washing, ultrasonic wave cleaning at acid/base solutions and active component re-impregnation method was recovered to 95% level of its activity compared to that of the fresh DPF, which was caused by removing the deactivating materials from the surface of the DPF, through the analyses of performance test and their surface characterization by Optical microscope, EDX, ICP, TGA, and porosimeter.

A Study of Carry Over Contamination in Chematology (이월오염에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Lyu, Jae-Gi;Jung, Dong-Jin;Kim, Gi-You;Park, Yong-Won;Chu, Kyung-Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

Validation on the Analytical Method of Ginsenosides in Red Ginseng

  • Cho B. G.;Nho K. B.;Shon H. J.;Choi K. J.;Lee S. K.;Kim S. C;Ko S. R.;Xie P. S.;Yan Y. Z.;Yang J. W.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.491-501
    • /
    • 2002
  • A cross-examination between KT&G Central Research Institute and Guangzhou Institute for Drug Control was carried out in order to select optimum conditions for extraction, separation and determination of ginsenosides in red ginseng and to propose a better method for the quantitative analysis of ginsenosides. The optimum extraction conditions of ginsenosides from red ginseng were as follows: the extraction solvent, $70\%$ methanol; the extraction temperature, $100^{\circ}C;$ the extraction time, 1 hour for once; and the repetition of extraction, twice. The optimum separation conditions of ginsenosides on the SepPak $C_{18}$ cartridge were as follows: the loaded amount, 0.4 g of methanol extract; the washing solvents, distilled water of 25 ml at first and then $30\%$ methanol of 25 ml; the elution solvent, $90\%$ methanol of 5 ml. The optimum HPLC conditions for the determination of ginsenosides were as follows: column, Lichrosorb $NH_2(25{\times}0.4cm,$ 5${\mu}m$, Merck Co.); mobile phase, a mixture of acetonitrile/water/isopropanol (80/5/15) and acetonitrile/water/isopropanol (80/20/15) with gradient system; and the detector, ELSD. On the basis of the optimum conditions a method for the quantitative analysis of ginsenosides were proposed and another cross-examination was carried out for the validation of the selected analytical method conditions. The coefficient of variances (CVs) on the contents of ginsenoside-$Rg_{1}$, -Re and $-Rb_1$ were lower than $3\%$ and the recovery rates of ginsenosides were $89.4\~95.7\%,$ which suggests that the above extraction and separation conditions may be reproducible and reasonable. For the selected HPLC/ELSD conditions, the CVs on the detector responses of ginsenoside-Rg, -Re and $-Rb_1$) were also lower than $3\%$, the regression coefficients for the calibration curves of ginsenosides were higher than 0.99 and two adjacent ginsenoside peaks were well separated, which suggests that the above HPLC/ELSD conditions may be good enough for the determination of ginsenosides.

  • PDF

Quality Characteristics of Canned Boiled Oyster and Canned Boiled Oyster in Bamboo Salt in Various Sterilization Conditions (살균조건에 따른 굴 보일드통조림 및 죽염 굴 보일드통조림의 식품 품질 특성)

  • Kong, Cheong-Sik;Je, Hae-Soo;Jung, Jae-Hun;Kwon, Soon-Jae;Lee, Jae-Dong;Yoon, Moon-Joo;Choi, Jong-Duck;Kim, Jeong-Gyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1231-1244
    • /
    • 2014
  • Oysters, especially are excellent source of several mineral including iron, zinc and selenium, which are often low in the mordern diet. They are also an excellent source of glycogen, vitamin B12 and considered the healthiest when eaten raw on the half shell in good tasted season from November to March. This study was investigated for the purpose of obtaining basic data which can be applied to processing of two kinds of canned boiled oyster (canned boiled oyster, canned boiled oyster in bamboo salt). Shucked oyster meat was cooked in steam (15min) after washing with water, filled 90g into can (301-3), added with salt solution and then precooked for 10 min. at $100^{\circ}C$. Canned boiled oyster was added 1.5% salt solution 60mL. Canned boiled oyster in bamboo salt was added 0.5% salt solution 30mL and 0.7% bamboo salt solution 30mL. The cans were seamed using a vacuum seamer, and then sterilized for various Fo values (Fo 8~12 min.) in a steam system retort at $116^{\circ}C$, $118^{\circ}C$. Viable bacterial count, proximate composition, pH, salinity, yield, VBN, amino-N, TBA, mineral, color value, free amino acid, hardness and sensory evaluation of two kinds of canned boiled oyster produced at various sterilization condition (Fo 8~12 min.) were measured after divide to meat and juice. The results showed that canned boiled oyster in bamboo salt sterilized at Fo 8 min. was the most desirable because this condition is the most economical and tasty.