Validation on the Analytical Method of Ginsenosides in Red Ginseng

  • Cho B. G. (KT&G Central Research Institute) ;
  • Nho K. B. (KT&G Central Research Institute) ;
  • Shon H. J. (KT&G Central Research Institute) ;
  • Choi K. J. (KT&G Central Research Institute) ;
  • Lee S. K. (KT&G Central Research Institute) ;
  • Kim S. C (KT&G Central Research Institute) ;
  • Ko S. R. (KT&G Central Research Institute) ;
  • Xie P. S. (Guangzhou Institute for Drug Control) ;
  • Yan Y. Z. (Guangzhou Institute for Drug Control) ;
  • Yang J. W. (KT&G Central Research Institute)
  • Published : 2002.10.01

Abstract

A cross-examination between KT&G Central Research Institute and Guangzhou Institute for Drug Control was carried out in order to select optimum conditions for extraction, separation and determination of ginsenosides in red ginseng and to propose a better method for the quantitative analysis of ginsenosides. The optimum extraction conditions of ginsenosides from red ginseng were as follows: the extraction solvent, $70\%$ methanol; the extraction temperature, $100^{\circ}C;$ the extraction time, 1 hour for once; and the repetition of extraction, twice. The optimum separation conditions of ginsenosides on the SepPak $C_{18}$ cartridge were as follows: the loaded amount, 0.4 g of methanol extract; the washing solvents, distilled water of 25 ml at first and then $30\%$ methanol of 25 ml; the elution solvent, $90\%$ methanol of 5 ml. The optimum HPLC conditions for the determination of ginsenosides were as follows: column, Lichrosorb $NH_2(25{\times}0.4cm,$ 5${\mu}m$, Merck Co.); mobile phase, a mixture of acetonitrile/water/isopropanol (80/5/15) and acetonitrile/water/isopropanol (80/20/15) with gradient system; and the detector, ELSD. On the basis of the optimum conditions a method for the quantitative analysis of ginsenosides were proposed and another cross-examination was carried out for the validation of the selected analytical method conditions. The coefficient of variances (CVs) on the contents of ginsenoside-$Rg_{1}$, -Re and $-Rb_1$ were lower than $3\%$ and the recovery rates of ginsenosides were $89.4\~95.7\%,$ which suggests that the above extraction and separation conditions may be reproducible and reasonable. For the selected HPLC/ELSD conditions, the CVs on the detector responses of ginsenoside-Rg, -Re and $-Rb_1$) were also lower than $3\%$, the regression coefficients for the calibration curves of ginsenosides were higher than 0.99 and two adjacent ginsenoside peaks were well separated, which suggests that the above HPLC/ELSD conditions may be good enough for the determination of ginsenosides.

Keywords