• Title/Summary/Keyword: Warm air

Search Result 307, Processing Time 0.023 seconds

Development and Commercialization of Warm Covers Using Natural Fabric (천연 소재를 이용한 보온덮개 개발 및 사업화 방안)

  • Choi, Ju-Hyun;Beak, Hyun-Kuk;Cho, Yun-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.227-233
    • /
    • 2018
  • The purpose of this study was to develop a warm cover for greenhouse with excellent thermal insulation and to propose ways of commercialization of the product. Feathers were used as filling materials because they formed the air layer to enhance insulation. Instead of downs for clothing or other textile products, we used disposed feathers. The developed product covers the outside of the greenhouse to keep the crops warm. It has multiple layers including feathers as filling materials, padding, inside fabric, heat insulation materials and outer fabric. It has proven to improve the insulation ratio. We developed other kinds of warm covers that are applicable to the inside of the greenhouse or the small houses in the greenhouse. Also, R&D system of educational industrial complex enables us to commercialize the products and building marketing strategies for them. This technology contributes to the expansion of energy-saving facilities for farmers, and it can serve the development and spread of various products utilizing feather.

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Evaluation of Ventilation Efficiency for Various Gravity Ventilators (자연환기 벤틸레이터 형태에 따른 환기효율 평가)

  • 하현철;김태형
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.543-551
    • /
    • 2002
  • Gravity ventilators allow the escape of the warm air and air contaminants due to both (either) buoyancy and (or) convection. As a natural ventilation strategy, various gravity ventilators can be installed on the roof. Ventilation efficiency could be affected by various parameters, such as, area of openings, wind velocity and incidence angle, temperature difference between inside and outside, and shape of ventilator. Especially, the shape of roof gravity ventilator might be one of influencing factors for the effective ventilation. The window type gravity ventilators are frequently installed instead of general (standard) gravity ventilator. However, the ventilation efficiencies of them were not proved yet. To compare the ventilation efficiency, general type ventilator and two window type ventilators were numerically tested. Mean age of air, temperature and CO concentration were predicted by using commercial CFD code, AIRPAK (Ver. 2.0) with various conditions. The predicted result showed that general type ventilator is more effective for natural ventilation than window type ventilators.

Interdecadal Changes in the Number of Days on Which Temperatures are not Higher Than -5℃ in Winter in Seoul (서울에서 겨울철 기온이 -5℃ 이하인 날 수의 십년간 변동 특성)

  • Choi, Jae-Won;Cha, Yumi;Kim, Jeoung-Yun;Park, Cheol-Hong
    • Journal of Climate Change Research
    • /
    • v.7 no.1
    • /
    • pp.49-57
    • /
    • 2016
  • In the present study, the time series of the number of days on which temperatures were not higher than $-5^{\circ}C$ in winter in Seoul was analyzed. The results showed a decreasing tendency until recently. Statistical change-point analysis was conducted to examine whether climate regime shifts existed in this time series. According to the results, the number of days on which temperatures were not higher than $-5^{\circ}C$ in winter in Seoul drastically decreased since 1988. Therefore, to find out the reason for the recent decrease in the number of days, differences between the means of large-scale environments in winder during 1988~2010 and those during 1974~1987 were analyzed. In all layers of the troposphere, anomalous anticyclones developed in regions around the Korean Peninsula and thus the Korean Peninsula was affected by westerlies or south-westerlies. This was associated with the recent a little further northward development of western North Pacific subtropical high. Therefore, environments good for warm and humid air to flow into the Korean Peninsula were formed. To examine whether relatively warm and humid air actually flowed into the Korean Peninsula recently, temperatures and specific humidity in all layers in the troposphere were analyzed and according to the results the Korean Peninsula showed warm and humid anomalies. In the analyses of sensible heat net flux and maximum temperatures at a height of 2 m that can be felt by humans, the East Asia Continent including the Korean Peninsula showed positive anomalies.

A Study on the Performance Test and Verification of Heat Transfer characteristics in Automobile Rear Window Heater (자동차 후면 유리 열선의 열전달특성에 따른 성애제거 성능평가 및 성능검증 방법에 관한 연구)

  • Juen, H.Y.;Lee, C.K.;Bae, H.J.;Lee, S.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2005
  • Both theoretical and experimental investigations were conducted to analyze defrosting behavior of a window heater operating in the low outdoor temperature($-20^{\circ}C$). To achieve this purpose, first a warm-chamber experiment($23^{\circ}C$) was performed to measure inner and outer surface temperature of the rear window(heated by the electric heater supplying 195 W) as functions of both time and position. Secondly, a cold chamber experiment was made to continuously record defrosting process of the frosted window. From the comparisons of the two experimental results, it was found that there was a similarity between the spatial distributions of both temperature and remaining frost. Thus, the temperature data from the warm-chamber experiments can be utilized to predict an expected zone covered with remaining frosts, and this approach can also be adopted in the inspection process in order to economically guarantee optimized performance of the window heater. Finally, an analytical model based on one-dimensional, steady-state heat transfer theories was proposed and successfully predicted the outer surface temperature of the rear window surrounded by cold air($-20^{\circ}C$) for the given operating conditions(heater power, inside and outside heat transfer coefficients, and surrounding air temperature, etc.).

  • PDF

A study on the EVA reforming processes transparency sheet and nonwoven warm air point adhesion using of tunnel waterproofing method. (EVA개질 투명시트와 부직포를 열풍 점융착한 일체형 방수시트를 이용한 터널방수공법에 관한 연구)

  • Seon Yun-Suk;Kim Jaun-Sull;Kim Su-Ryon;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.185-190
    • /
    • 2005
  • Safe, economical and environment-friendly tunnel construction are required again along with social continuous development, the importance of waterproof work that is portion that actually all of user and builder can find that is embossed by tunnel construction's one of important construction. Also, ECB (Ethylen Copolymer Bitumen) sheet that is used in existing tunnel waterproofing method (ECB waterproofing method) being black because asphalt (Bitumen) is added, by purpose that make illumination of tunnel interior brightly and scar discovery eases in sheet with coating white film, but ECB that is used present according as ECB that asphalt is added does not satisfy high tensile strength of construction field, quality standard of extension. Also ECB denigrates color of black M/B that asphalt is excepted.

  • PDF

Observational Study on Local Climatological Environment of the Mountain Adjacent the Dongyeong Herb Garden in Chilgok (칠곡 동영 약초원 인근 산지의 국지 기후 환경 관측 연구)

  • Kim, Hak-Yun;Choi, Seo-Hwan;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.897-904
    • /
    • 2016
  • We investigated the local climatological characteristics of the mountain adjacent the Dongyeong herb garden in Chilgok. We established one set of automatic weather system (AWS) on a hill where development of herb garden is in progress. The observations were continued for 2 years(2013. 07-2015.06). In this study, we analyzed the observed data comparing the data of Gumi meteorological observatory (GMO). The results showed that the air temperature(relative humidity) of Dongyeong herb garden were lower(higher) than those of GMO. Especially the differences are more during warm climate season. It means that the gaps of thermal environment between two points are mainly caused by the evaporation effects of forest. In addition, we analyzed the warmth indices(warmth index and coldness index) with the observed air temperature. The warmth and coldness indices indicate about 107 and -12, respectively. The values correspond to warm temperature climate.

A Case Study of Heavy Rainfall by A Developed Convective System over Gangneung on 6 August 2018 (2018년 8월 6일 발달한 대류계에 의해 발생한 강릉지역의 집중호우 사례 연구)

  • Park, Sung-Kyu;Lee, Jae Gyoo
    • Atmosphere
    • /
    • v.30 no.2
    • /
    • pp.125-139
    • /
    • 2020
  • On 6 August 2018, heavy rainfall of daily precipitation of more than 200 mm occurred in the Yeong-dong coastal area, and especially, 1-hour precipitation of 93 mm (0251~0351 LST (local standard time) 6 August) at Gangneung station, ranked second in the history of meteorological survey of the station. In this study, this heavy rainfall case over the Gangneung area would be studied to investigate the process in which the heavy rainfall occurred. A developed ridge moved toward the Yeong-dong coastal area from the Maritime Province in Russia. The approaching of the ridge led to the northeasterly cold wind over the coastal region, causing the collision between the incoming northeasterly cold wind, and the humid and warm (convectively unstable) air located over the Yeong-dong area. This collision led to a strong convergence (maximum -206 × 10-5 s-1) at 925 hPa level over the vicinity of Gangneung at 0300 LST 6 August, resulting updraft of up to about 4.4 m s-1 at 700 hPa level over the area. This strong updraft forced to lift rapidly the convectively unstable, warm and humid air layer, located over the vicinity of Gangneung, leading to the heavy rainfall (1-hour precipitation of 93 mm) over the area.

An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator (맥동관 냉동기 열교환기에 관한 실험적 연구)

  • 남관우;정상권;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

INVESTIGATION OF RUNNING BEHAVIORS OF AN LPG SI ENGINE WITH OXYGEN-ENRICHED AIR DURING START/WARM-UP AND HOT IDLING

  • Xiao, G.;Qiao, X.;Li, G.;Huang, Z.;Li, L.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.437-444
    • /
    • 2007
  • This paper experimentally investigates the effects of oxygen-enriched air (OEA) on the running behaviors of an LPG SI engine during both start/warm-up (SW) and hot idling (HI) stages. The experiments were performed on an air-cooled, single-cylinder, 4-stroke, LPG SI engine with an electronic fuel injection system and an electrically-heated oxygen sensor. OEA containing 23% and 25% oxygen (by volume) was supplied for the experiments. The throttle position was fixed at that of idle condition. A fueling strategy was used as following: the fuel injection pulse width (FIPW) in the first cycle of injection was set 5.05 ms, and 2.6 ms in the subsequent cycles till the achieving of closed-loop control. In closed-loop mode, the FIPW was adjusted by the ECU in terms of the oxygen sensor feedback. Instantaneous engine speed, cylinder pressure, engine-out time-resolved HC, CO and NOx emissions and excess air coefficient (EAC) were measured and compared to the intake air baseline (ambient air, 21% oxygen). The results show that during SW stage, with the increase in the oxygen concentration in the intake air, the EAC of the mixture is much closer to the stoichiometric one and more oxygen is made available for oxidation, which results in evidently-improved combustion. The ignition in the first firing cycle starts earlier and peak pressure and maximum heat release rate both notably increase. The maximum engine speed is elevated and HC and CO emissions are reduced considerably. The percent reductions in HC emissions are about 48% and 68% in CO emissions about 52% and 78%; with 23% and 25% OEA, respectively, compared to ambient air. During HI stage, with OEA, the fuel amount per cycle increases due to closed-loop control, the engine speed rises, and speed stability is improved. The HC emissions notably decrease: about 60% and 80% with 23% and 25% OEA, respectively, compared to ambient air. The CO emissions remain at the same low level as with ambient air. During both SW and HI stages, intake air oxygen enrichment causes the delay of spark timing and the increased NOx emissions.