• Title/Summary/Keyword: Walls

Search Result 4,321, Processing Time 0.038 seconds

Performance-based drift prediction of reinforced concrete shear wall using bagging ensemble method

  • Bu-Seog Ju;Shinyoung Kwag;Sangwoo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2747-2756
    • /
    • 2023
  • Reinforced Concrete (RC) shear walls are one of the civil structures in nuclear power plants to resist lateral loads such as earthquakes and wind loads effectively. Risk-informed and performance-based regulation in the nuclear industry requires considering possible accidents and determining desirable performance on structures. As a result, rather than predicting only the ultimate capacity of structures, the prediction of performances on structures depending on different damage states or various accident scenarios have increasingly needed. This study aims to develop machine-learning models predicting drifts of the RC shear walls according to the damage limit states. The damage limit states are divided into four categories: the onset of cracking, yielding of rebars, crushing of concrete, and structural failure. The data on the drift of shear walls at each damage state are collected from the existing studies, and four regression machine-learning models are used to train the datasets. In addition, the bagging ensemble method is applied to improve the accuracy of the individual machine-learning models. The developed models are to predict the drifts of shear walls consisting of various cross-sections based on designated damage limit states in advance and help to determine the repairing methods according to damage levels to shear walls.

Passive p-y curves for rigid basement walls supporting granular soils

  • Imad, Elchiti;George, Saad;Shadi S., Najjar
    • Geomechanics and Engineering
    • /
    • v.32 no.3
    • /
    • pp.335-346
    • /
    • 2023
  • For structures with underground basement walls, the soil-structure-interaction between the side soil and the walls affects the response of the system. There is interest in quantifying the relationship between the lateral earth pressure and the wall displacement using p-y curves. To date, passive p-y curves in available limited studies were assumed elastic-perfectly plastic. In reality, the relationship between earth pressure and wall displacement is complex. This paper focuses on studying the development of passive p-y curves behind rigid walls supporting granular soils. The study aims at identifying the different components of the passive p-y relationship and proposing a rigorous non-linear p-y model in place of simplified elastic-plastic models. The results of the study show that (1) the p-y relationship that models the stress-displacement response behind a rigid basement wall is highly non-linear, (2) passive p-y curves are affected by the height of the wall, relative density, and depth below the ground surface, and (3) passive p-y curves can be expressed using a truncated hyperbolic model that is defined by a limit state passive pressure that is determined using available logarithmic spiral methods and an initial slope that is expressed using a depth-dependent soil stiffness model.

Seismic reliability of precast concrete frame with masonry infill wall

  • Mahdi Adibi;Roozbeh Talebkhah;Hamid Farrokh Ghatte
    • Earthquakes and Structures
    • /
    • v.24 no.2
    • /
    • pp.141-153
    • /
    • 2023
  • The presented paper considers infill masonry walls' influence on the seismic reliability of precast concrete frames. The recent Bojnord earthquake on May 13th, 2017 in Iran (MW 5.4) illustrated that the infill masonry walls play a crucial role in the damage extent and life safety issues of inhabitants in the precast concrete buildings. The incremental dynamic analysis (IDA) approach was used to determine the fragility curves of the represented damaged precast frame. Then, by integrating site hazard and structural fragilities, the seismic reliability of the represented precast frame was evaluated in different damage limit states. Additionally, the static pushover analysis (SPA) approach was used to assess the seismic performance assessment of the precast frame. Bare and infilled frames were modeled as 2D frames employing the OpenSees software platform. The multi-strut macro-model method was employed for infill masonry simulation. Also, a relatively efficient and straightforward nonlinear model was used to simulate the nonlinear behavior of the precast beam-column joint. The outputs show that consideration of the masonry infilled wall effect in all spans of the structural frame leads to a decrease in the possibility of exceedance of specified damage limit states in the structures. In addition, variation of hazard curves for buildings with and without consideration of infilled walls leads to a decrease in the reliability of the building's frames with masonry infilled walls. Furthermore, the lack of infill walls in the first story significantly affects the precast concrete frame's seismic reliability and performance.

Development of stability evaluation system for retaining walls: Differential evolution algorithm-artificial neural network

  • Dong-Gun Lee;Sang-Yun Lee;Ki-Il Song
    • Geomechanics and Engineering
    • /
    • v.34 no.3
    • /
    • pp.329-339
    • /
    • 2023
  • The objective of this study is to develop a Stability Evaluation System for retaining walls to assess their safety in real-time during excavation. A ground investigation is typically conducted before construction to gather information about the soil properties and predict wall stability. However, these properties may not accurately reflect the actual ground being excavated. To address this issue, the study employed a differential evolution algorithm to estimate the soil parameters of the actual ground. The estimated results were then used as input for an artificial neural network to evaluate the stability of the retaining walls. The study achieved an average accuracy of over 90% in predicting differential settlement, wall displacement, anchor force, and structural stability of the retaining walls. If implemented at actual excavation sites, this approach would enable real-time prediction of wall stability and facilitate effective safety management. Overall, the developed Stability Evaluation System offers a promising solution for ensuring the stability of retaining walls during construction. By incorporating real-time soil parameter analysis, it enhances the accuracy of stability predictions and contributes to proactive safety management in excavation projects.

Seismic Design Force for Rectangular Water Tank with Flexible Walls (유연한 벽면을 가진 사각형 물탱크의 설계지진력 산정)

  • Kim, Min Woo;Yu, Eunjong;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.303-310
    • /
    • 2023
  • The equivalent static load for non-structural elements has a limitation in that the sloshing effect and the interaction between the fluid and the water tank cannot be considered. In this study, the equations to evaluate the impulse and convective components in the design codes and previous research were compared with the shaking table test results of a rectangular water tank with flexible wall panels. The conclusions of this study can be summarized as follows: (1) It was observed that the natural periods of the impulsive component according to ACI 350.3 were longer than system identification results. Thus, ACI 350.3 may underestimate the earthquake load in the case of water tanks with flexible walls. (2) In the case of water tanks with flexible walls, the side walls deform due to bending of the front and back walls. When such three-dimensional fluid-structure interaction was included, the natural period of the impulsive component became similar to the experimental results. (3) When a detailed finite element (FE) model of the water tank was unavailable, the assumption Sai = SDS could be used, resulting in a reasonably conservative design earthquake load.

Changing Aspects of the Wall Types of Hahoe Village (하회마을 담장 형태의 변화양상)

  • Kim, Dong-Hyun;Lee, Won-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.5
    • /
    • pp.87-96
    • /
    • 2017
  • This study focuses on the Andong Hahoe Village and seeks to identify the shape of the walls since the 1970s. The change of walls can be divided into four periods based on characteristics of materials, shape and distribution. The following is a summary of the results: First, In the 1970s, when Andong Hahoe Village was not designated as a cultural heritage, roof tiles hung on the earthen walls in the middle of the village were major forms. On the outside of the village, rice straw and pine needles were put on the earthen walls or bush clover walls were put in place around if walls were not built. Second, after being designated as a cultural heritage in the 1980s, readjustments for cultural heritages were carried out at the primary stage. However, the distribution of cultural heritages and major changes were not determined at this time since readjustments were mainly focused on the renovation of derelict houses or maintenance of infrastructures. Third, in the past the use of stone bricks for the Hahoe Village site had been difficult, but in the 1990s, replacements with soil-stone walls were identified and the usage of roof tiles increased. The portion of earthen walls, which used to be the major form in the prior era, decreased and this seems to have continued until the 2000s. Fourth, via a field survey, it was found that most of Hahoe village walls consisted of soil cement bricks mixed with cement, steel, lime, gravel. etc. Also, the scope of straw-stricken walls and bush clover walls were reduced to a section of area outside of the village. Fifth, from the 1970s to the present, there were changes to the walls in Hahoe Village including an increase in usages of new materials and an expansion of houses with tiled roofs on top in accordance with the replacement of walls of existing houses. Relevant reasons for this have been identified, such as the fading value of Fungsui(風水) and lack of original records, insufficient awareness and expertise in non-building areas, and the relationship between residents on repairing the wall.

Analysis of unreinforced masonry (URM) walls and evaluation of retrofitting schemes for URM structures

  • Mehta, Sanjay;Saadeghvaziri, M.A.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.7
    • /
    • pp.801-815
    • /
    • 1998
  • An overview of an analytical model to predict mortar joint failure in unreinforced masonry (URM) structures is presented. The validity of the model is established by comparison with experimental results at element level as well as structure level. This model is then used to study the behavior of URM walls and two commonly used retrofitting schemes. Finally, effectiveness of the two retrofitting schemes in increasing strength and stiffness of existing URM walls is discussed.

Strength of Low Rise Structural Walls Using High Strength Concrete (고강도 콘크리트를 사용한 저층형 내력벽의 강도)

  • 윤현도;최창식;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.407-410
    • /
    • 1999
  • An experimental investigation to study the behavior of low rise structural walls using high strength concrete is presented. The test parameter included in the study were the level of constant axial load. The shear strength of walls is predicted by the design provision given in the current the American Concrete Institute Building Code ACI 318-95 and Architectural Institute Japan Code AIJ. The predictions are compared with the test results reported herein as well as those available in the literature.

  • PDF

Effects of Web Reinforcement Amount on Hysteretic Behavior of High Strength Reinforced Concrete Structural Walls (전단보강근비에 따른 고강도 철근콘크리트 내력벽의 이력특성)

  • 최근도;정학영;윤현도;최장식;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.85-90
    • /
    • 1994
  • Three high strength reinforced concrete structural walls were tested under the combined action of a constant axial and a horizontal cycle load. The aim of the tests has been to investigate the effects of the web horizontal reinforcement on hysteretic behavior of wall. The results have helped to identify the causes of wall failure and have demonstrated the web horizontal reinforcement does not appear have a significant effect on shear capacity, stiffness and energy dissipation but have a significant effect on the failure mode of the walls.

  • PDF

Lessons Learned from Failure of Geogrid-Reinforced Segmental Retaining Wall (블록식 보강토 옹벽의 하자발생 사례 분석)

  • 신은철;오영인;김종인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.329-336
    • /
    • 2001
  • The numbers of geogrid-reinforced walls are widely used in Korea. This papers present the results of two failure case histories of geogrid-reinforced segmental retaining walls. The geological background of the construction sites, detailed construction sequences, and the amount of rainfall were examined. The failure of these reinforced walls are caused by the improper drainage system and foundation treatment, too sharpened curvature of corner work, and too high height of wall.

  • PDF