• Title/Summary/Keyword: Wall-thinned pipe with reinforcement

Search Result 4, Processing Time 0.025 seconds

Efficient elastic stress analysis method for piping system with wall-thinning and reinforcement

  • Kim, Ji-Su;Jang, Je-Hoon;Kim, Yun-Jae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.732-740
    • /
    • 2022
  • A piping system stress analysis need to be re-performed for structural integrity assessment after reinforcement of a pipe with significant wall thinning. For efficient stress analysis, a one-dimensional beam element for the wall-thinned pipe with reinforcement needs to be developed. To develop the beam element, this work presents analytical equations for elastic stiffness of the wall-thinned pipe with reinforcement are analytically derived for axial tension, bending and torsion. Comparison with finite element (FE) analysis results using detailed three-dimensional solid models for wall-thinned pipe with reinforcement shows good agreement. Implementation of the proposed solutions into commercial FE programs is explained.

Analytical Equivalent Stiffness Analysis for Various Reinforcements of Wall-thinned Pipe (감육 배관의 다양한 보강 형태에 따른 이론적 등가 강성 검증)

  • Je-Hoon Jang;Ji-Su Kim;Yun-Jae Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • When wall-thinning in a pipe occurs during operation of nuclear power plant, reinforcement of the pipe needs to be performed. Accordingly, the structural response of the piping system due to introduction of the reinforcement may be re-evaluated. For elastic structural analysis of the piping system with the reinforced pipe using finite element (FE) analysis, the stiffness of the reinforced pipe is needed. In this study, the stiffness matrix of wall-thinned pipe with pad reinforcement or composite reinforcement is analytically derived. The validity of the proposed equations is checked by comparing with systematic finite element (FE) analysis results.

Stress evaluation method of reinforced wall-thinned Class 2/3 nuclear pipes for structural integrity assessment

  • Jae-Yoon Kim;Je-Hoon Jang;Jin-Ha Hwang;Yun-Jae Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1320-1329
    • /
    • 2024
  • When wall-thinning occurs in nuclear Class 2 and 3 pipes, reinforcement is typically applied rather than replacement. To analyze the structural integrity of reinforced wall-thinned pipe, stress analysis results using full 3-D FE analysis are not compatible to the design code equation, ASME BPVC Sec. III NC/ND-3650. Therefore, the efficient stress evaluation method for the reinforced wall-thinned pipe, compatible to the design code equation, needs to be developed. In this paper, stress evaluation methods for the reinforced wall-thinned pipe are proposed using the equivalent straight pipe concept. Furthermore, for fatigue analysis of the reinforced wall-thinned pipe, the stress intensification factor of reinforced wall-thinned pipe is presented using the structural stress method given in ASME BPVC Sec. VIII Div.2.

Stress Evaluation and Case Study of Reinforced Wall-thinned Class 2 and 3 Pipes in Operating Nuclear Power Plants Using Equivalent Stiffness Concept (등가 강성 개념을 이용한 가동 원전 2, 3등급 감육 보강 배관의 응력 평가 및 사례해석)

  • Xinyu Ma;Jae Yoon Kim;Jin Ha Hwang;Yun Jae Kim;Man Won Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.54-60
    • /
    • 2022
  • ASME BPVC provides stress evaluation rules for Class 2 and 3 nuclear piping. However, such rules are difficult to be applied to reinforced wall-thinned pipes during service. To resolve this issue, a new method for stress evaluation of reinforced wall-thinned pipes is proposed in this work, based on the equivalent stiffness concept. By converting a reinforced wall-thinned pipe to an equivalent straight pipe having the same stiffness, stress evaluation can be proceeded using the current ASME BPVC rules. The proposed method is applied to pipes with 4 different normal pipe size and the effects of reinforcement and wall-thinning dimensions on evaluated stresses are discussed.