• Title/Summary/Keyword: Wall thickness

Search Result 1,567, Processing Time 0.026 seconds

Electro-Optical characteristics with dielectric thickness of AC-PDP

  • Jung, K.B.;Choi, J.H.;Kim, S.B.;Jung, Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.768-770
    • /
    • 2003
  • In AC PDP, since charges generated by gas discharge are accumulated on the dielectric. The dielectric is a major factor to determine cell capacitance and its memory effect is a play an important role in PDP driving. In this experiment, we have investigated the electro-optical characteristics with dielectric thickness and we have analyzed wall charge and wall voltage by Q-V energy diagram. The dielectric thickness was varied from 20 um to 50 um. As results, according to the dielectric thickness increase,cell capacitance and power consumption is reduced.

  • PDF

Design Strength of Coupled Shear Wall System according to Variation of Strength and Stiffness of Coupled Shear Wall (병렬전단벽의 강도와 강성이 커플링보의 설계내력에 미치는 영향)

  • Yoon, Tae-Ho;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.743-750
    • /
    • 2016
  • In this research, the effects of the strength and stiffness of shear walls on the design strength of coupling beams are studied in the shear wall-coupling beam structural system widely used as the lateral-drift resistant system of high-rise buildings. The results show that the design strength of the coupling beams decreases with decreasing concrete strength and core wall thickness, but the shape remains unchanged. In all six models, the design strength of the coupling beams has the largest value at the 10~15th floors in a 40-story building. In other words, the design strength of the coupling beams has the largest value at 0.25H~0.375H where the inflection point exists. The thicker the walls, the smaller the change in the member forces. The thickness of the coupled shear walls has more influence on the design strength of the coupling beams than the concrete strength.

Bowel Wall Thickening on Computed Tomography in Children: A Novel Method of Measurement and Its Clinical Significance

  • Lee, Do Kyung;Cho, Ky Young;Cho, Hyun-hae;Seo, Jeong Wan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.3
    • /
    • pp.279-287
    • /
    • 2021
  • Purpose: The clinical implications of bowel wall thickening (BWT) on abdominal computed tomography (CT) among children are unknown. We aimed to suggest a new method for measuring BWT and determining its clinical significance in children. Methods: We retrospectively analyzed 423 patients with acute abdomen who underwent abdominal CT; 262 were classified into the BWT group. For this group, the pediatric radiologist described the maximal bowel wall thickness (MT), normal bowel wall thickness (mm) (NT), and their ratios for each segment of the bowel wall. Results: In the thickened bowel walls, the thickness differed significantly between the small bowel (6.83±2.14 mm; mean±standard deviation) and the colon (8.56±3.46 mm; p<0.001). The ratios of MT to NT in the small bowel (6.09±3.17) and the colon (7.58±3.70) were also significantly different (p<0.001). In the BWT group, 35 of 53 patients had positive fecal polymerase chain reaction results; 6 patients infected with viruses predominantly had BWT in the small intestine, while the terminal ileum and the colon were predominantly affected in 29 patients with bacterial infections. In the initially undiagnosed 158 patients with BWT, the symptoms improved spontaneously without progression to chronic gastrointestinal disease. Conclusion: This study provides a clinical reference value for BWT in the small intestine and colon using a new method in children. The BWT on abdominal CT in children might indicate nonspecific findings that can be observed and followed up without additional evaluation, unlike in adults.

The Effect of Composite Ratio and Wall Thickness on the Shear Behavior of Composite Basement Wall (합성율과 벽체두께가 합성지하벽의 전단거동에 미치는 영향)

  • Seo, Soo-Yeon;Kim, Seong-Soo;Yoon, Yong-Dae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • When doing underground excavation works for the purpose of constructing large underground structures for a building in the limited space in downtown area, the stability of the adjacent ground must be top priority, and to accomplish this, it is essential to review the retaining wall construction carefully. H-Pile, which has been mainly used as a stress-carrying material in temporary earth-retaining structures, is most likely to be abandoned after completion of the works for the basement exterior wall in relation to contiguous bored piles, so it will result in a waste of material. To improve this situation, Basement Composite Wall where H-Pile and basement wall are compounded, has been developed. This wall is being used most frequently in many local construction sites. In this study, five specimens are made in order to evaluate the shear resistance of the basement composite wall and tested. Test parameter is the composition ratio and wall thickness according to shear connectors. Test result shows that the shear strength is improved when the composite ratio is increased but the magnitude is not much. A formula, which considers the contribution of concrete, web of H-pile as well as flange' effect in calculation of shear strength of composite basement wall, is suggested and used to calculation of the strength of specimens. It is found that there is a good co-relation between test result and the calculated one by the formula.

A numerical study of a confined turbulent wall jet with an external stream

  • Yan, Zhitao;Zhong, Yongli;Cheng, Xu;McIntyre, Rory P.;Savory, Eric
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.101-109
    • /
    • 2018
  • Wall jet flow exists widely in engineering applications, including the simulation of thunderstorm downburst outflows, and has been investigated extensively by both experimental and numerical methods. Most previous studies focused on the scaling laws and self-similarity, while the effect of lip thickness and external stream height on mean velocity has not been examined in detail. The present work is a numerical study, using steady Reynolds-Averaged Navier Stokes (RANS) simulations at a Reynolds number of $3.5{\times}10^4$, of a turbulent plane wall jet with an external stream to investigate the influence of the wall jet domain on downstream development of the flow. The comparisons of flow characteristics simulated by the Reynolds stress turbulence model closure (Stress-omega, SWRSM) and experimental results indicate that this model may be considered reasonable for simulating the wall jet. The confined wall jet is further analyzed in a parametric study, with the results compared to the experimental data. The results indicate that the height and the width of the wind tunnel and the lip thickness of the jet nozzle have a great effect on the wall jet development. The top plate of the tunnel does not confine the development of the wall jet within 200b of the nozzle when the height of the tunnel is more than 40b (b is the height of jet nozzle). The features of the centerline flow in the mid plane of the 3D numerical model are close to those of the 2D simulated plane wall jet when the width of the tunnel is more than 20b.

Geometric variations and surface residual stresses in U-bending processes of an UNS N06690 row-1 heat exchanger tubes (UNS N06690 제1열 시제전열관의 U-굽힘성형에서 형상변화와 표면잔류응력)

  • Kim, Woo-Gon;Jang, Jin-Sung;Kuk, Il-Hiun;Joo, Jin-Won;Kim, Sung-Chung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.238-246
    • /
    • 1998
  • Surface residual stresses as well as wall thickness and ovality changes after U-bending process on UNS N06690 row-1 heat exchanger tubes, were estimated. Surface residual stresses were measured by Hole Drilling Method(HDM), calculating the stresses from relieved strains of 3 rosette strain gages. After bending of the tubes, dimensional tolerances for wall thickness and ovality were satisfied with ASTM requirements. Residual stresses at the extrados were introduced with compressive stress(-) by bending operations, and its maximum value reached-319 MPa in axial direction at ${\phi}=0^{\circ}$ in position. Tensile residual stresses(+) of ${\sigma}_zz=45$ MPa,${\sigma}_zz=25$ MPa were introduced in the intrados surface at position of ${\phi}=0^{\circ}$ Maximum tensile residual stress of 170 MPa was detected on the flank side at position of ,${\phi}=95^{\circ}$i.e., at apex region. It appeared that higher stress gradients were generated at the irregular transition regions. In the trend of residual stress changes with U-bend position, the extrados is related with the changes of ovality and the intrados is related with the changes of wall thickness.

Anatomical Characteristics and Air-dry Density of Young Trees of Teak Clones Planted in Indonesia

  • Hidayati, Fanny;Ishiguri, Futoshi;Marsoem, Sri Nugroho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.463-470
    • /
    • 2017
  • The objectives of this study are to obtain the basic knowledge of anatomical characteristics and wood properties of thinning trees of young teak (Tectona grandis L.F.) for fulfill the timber demand in Indonesia. Nine thinning trees of 5-year-old teak clone trees were used for analyzing the cell morphology and air-dry density. Vessel diameters in pore and outer pore zones were 165 and $90{\mu}m$, respectively. Mean value of fiber diameter, cell wall thickness, and fiber length in outer pore zone were $14.6{\mu}m$, $2.07{\mu}m$, and 1.04 mm, respectively. In addition, mean value of air-dry density was $0.55g/cm^3$. The measurement and values of vessel diameter, fiber diameter, cell wall thickness, fiber length and air-dry density in the experimental had lower than those in the older teak. Therefore, it could be suggested that the wood from thinning young teaks was not appropriate as construction material, but it could be used for furniture which do not need high of strength properties. Furthermore, since the measurements values of anatomical characteristics were still increasing from pith to bark, it could be suggested that 5-year-old teak clones are still in a juvenile phase. Positively significant correlations were found between air-dry density and cell wall thickness, indicating that cell wall thickness is strongly correlated with wood density of teak.

Differential diagnosis of ovarian cysts using ultrasonogrphy and progesterone assay in slaughtered cows (초음파검사 및 혈중 progesterone 농도측정에 의한 도축우 유래 난소낭종의 감별진단)

  • 박상국;김상욱;임종수;박장일;정만호
    • Korean Journal of Veterinary Service
    • /
    • v.21 no.1
    • /
    • pp.57-66
    • /
    • 1998
  • To establish the differential diagnosis and treatment method in bovine ovarian cysts, specially ovarian cysts with corpus luteum, serum progesterone concentration and ulrasonography for measuring the cyclic area, thickness of cystic wall and echogenicity of corpus luteum were investigated in cystic ovaries from slaughtered cows. The incidence rates of ovarian cysts were follicular cyst 69.2% and luteal cyst 30.8%. The incidence rates of 8 various types of ovarian cysts were as follows; 2Ba 32.3%, 2Aa 25.8% and 2Bb 14.5%, respectively. The thickness of cystic wall were 2Bb 3.93mm, 2Ab 3.70mm and 1Aa 1.93mm and the serum progesterone concentrations were above 1.0ng/$m\ell$ in 2Ab, 2Bb and IAa, respectively. The cystic area of ovarian cysts with corpus luteum was 288.30mm2, but ovarian cysts without corpus luteum 542.30$\textrm{mm}^2$, and the thickness of cystic wall 2.12mm and 2.40mm, respectively. The serum progesterone concentration was 1.91ng/$m\ell$ in ovarian cysts with corpus luteum and 1.20ng/$m\ell$ ovarian cysts without corpus luteum. There was not the correlations between thickness of cystic wall and serum progesterone concentration in ovarian cysts with corpus luteum, whereas, was the correlations in ovarian cysts without corpus. These results indicated that PGF2$\alpha$ analogues can be choice for treating the ovarian cysts with corpus luteum because serum progesterone concentrations were above 1.0ng/$m\ell$ in ovarian cysts with corpus luteum. In conclusion, it is suggest that ultrasonography is useful diagnostic tool for diagnosing and choicing of treatment remedy in cystic ovaries of bovine.

  • PDF

Effects of Electroacupuncture at Zusanli (ST36) on Ultrasonographic Gastric Emptying: A Pilot Study in Healthy Adults (족삼리 전침 자극이 초음파로 측정된 위배출능에 미치는 영향 : 건강인 대상 예비연구)

  • Ha, Na-yeon;Park, Jae-woo;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.3
    • /
    • pp.426-442
    • /
    • 2018
  • Objective: This study aimed to compare the effects of Zusanli and nonacupoint electroacupuncture stimulation on ultrasonographic gastric emptying and vital signs in eight healthy participants. Gastric emptying and its rate of change were analyzed to search for correlation with physical characteristics such as body mass index (BMI), sternocostal angle, and abdominal wall thickness. Methods: Eight healthy participants with no gastrointestinal disorders were enrolled in this study. Each participant went through three abdominal sonographies for gastric emptying assessment. At the second and third visits, participants received Zusanli and nonacupoint electroacupuncture stimulation in a random order. During the study period, we examined the BMI, sternocostal angle, and abdominal wall thickness of all participants. Vital signs (blood pressure, heart rate, and temperature) were also examined before and after the electroacupuncture stimulation. Results: Electroacupuncture stimulation at Zusanli significantly improved gastric emptying when compared to nonacupoint stimulation. Gastric emptying showed a positive correlation with BMI, sternocostal angle, and abdominal wall thickness, but this correlation was statistically insignificant. The improvement rate of gastric emptying by Zusanli electroacupuncture stimulation showed a positive correlation with BMI and sternocostal angle and a negative correlation with abdominal wall thickness. However, such results were also statistically insignificant. Among vital signs, only heart rate showed a significant decrease according to Zusanli electroacupuncture stimulation. Conclusions: A significant effect of Zusanli electroacupuncture was confirmed through ultrasonographic gastric emptying in healthy participants.