Browse > Article
http://dx.doi.org/10.11112/jksmi.2010.14.1.093

The Effect of Composite Ratio and Wall Thickness on the Shear Behavior of Composite Basement Wall  

Seo, Soo-Yeon (충주대학교 건축공학과)
Kim, Seong-Soo (청주대학교 건축공학과)
Yoon, Yong-Dae (청주대학교 건축공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.14, no.1, 2010 , pp. 93-101 More about this Journal
Abstract
When doing underground excavation works for the purpose of constructing large underground structures for a building in the limited space in downtown area, the stability of the adjacent ground must be top priority, and to accomplish this, it is essential to review the retaining wall construction carefully. H-Pile, which has been mainly used as a stress-carrying material in temporary earth-retaining structures, is most likely to be abandoned after completion of the works for the basement exterior wall in relation to contiguous bored piles, so it will result in a waste of material. To improve this situation, Basement Composite Wall where H-Pile and basement wall are compounded, has been developed. This wall is being used most frequently in many local construction sites. In this study, five specimens are made in order to evaluate the shear resistance of the basement composite wall and tested. Test parameter is the composition ratio and wall thickness according to shear connectors. Test result shows that the shear strength is improved when the composite ratio is increased but the magnitude is not much. A formula, which considers the contribution of concrete, web of H-pile as well as flange' effect in calculation of shear strength of composite basement wall, is suggested and used to calculation of the strength of specimens. It is found that there is a good co-relation between test result and the calculated one by the formula.
Keywords
Basement Composite Wall; Shear Connector; Composite Ratio; Wall Thickness; Formula;
Citations & Related Records
연도 인용수 순위
  • Reference
1 서수연, 김재엽, 하기주, 무지주 지하옹벽 거푸집 시공시의 압축지지대, 특허 제10-0728207호
2 이성호, 역T형 합성 지하벽의 구조적 거동에 관한 실험적 연구, 한양대학교 박사학위논문, 2002.
3 R. Park, "Evaluation of Ductility of Structures and Structural Assemblages from Laboratory Testing," Bulletin of The New Zealand National Society for Earthquake Engineering, Vol. 22, No. 3, September, 1989.
4 Zsutty, Theodore C, "Beam Shear Strength Prediction by Analysis of Existing Data", ACI Journal, Proceedings V. 65, No. 11, Nov., 1968.
5 JSCE, "Standard Specification for Design and Construction of Concrete Structures", Part I(Design), Japan Society of Civil Engineers, Tokyo, 1991.
6 초대형 구조 시스템 연구 센터, 삼성중공업(주), "CBS 공법의 개발 및 성능 평가에 관한 연구", 2001.
7 AISC Committee on the Code of Standard Practice, Code of Standard Practice for Steel Buildings and Bridges, ASIC 360-05, American Institute of Steel Construction, Inc., Chicago, IL, 2005
8 ACI Committee 318, Building Code Requirements for Structural Concrete(ACI318-08) and Commentary (AC I318R-08), ACI, 2008
9 Bazant, Zdenek P., and Kim, Jin-Keun, "Size Effect in Shear Failure of Longitudinally Reinforced Beams", ACI Journal, Proceedings V. 81, No. 5, Sept.-Oct., 1984.