• Title/Summary/Keyword: Wall system

Search Result 3,577, Processing Time 0.028 seconds

Analysis of Shear Wall with Openings Using Super Element (슈퍼요소를 이용한 개구부를 가진 전단벽의 해석)

  • 이동근;김현수;남궁계홍
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.343-350
    • /
    • 2001
  • The box system, composed only of reinforced concrete walls and slabs, are adopted by many high-rise apartment buildings recently constructed in Korea. In the buildings, one or more relatively large openings are cut in a shear wall for functional reasons. The openings influence the internal stress of the shear wall and also the structural behavior. Therefore, it is necessary to use subdivided plate elements for accurate analysis of the box system with openings. But it would cost tremendous amount of analysis time and computer memory if the shear wall is subdivided into a finer mesh in the analysis of high-rise buildings. So, it is difficult to apply this modeling method to practical procedure. In this study, an efficient method is proposed for the efficient and accurate analysis of shear wall with openings. The proposed method used the super element and matrix condensations, fictitious beam technique.

  • PDF

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.

A Water-Wall Model of Supercritical Once-Through Boilers Using Lumped Parameter Method

  • Go, Geon;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1900-1908
    • /
    • 2014
  • This paper establishes a compact and practical model for a water-wall system comprising supercritical once-through boilers, which can be used for automatic control or simple analysis of the entire boiler-turbine system. Input and output variables of the water-wall system are defined, and balance equations are applied using a lumped parameter method. For practical purposes, the dynamic equations are developed with respect to pressure and temperature instead of density and internal energy. A comparison with results obtained using APESS, a practical thermal power plant simulator developed by Doosan Heavy Industries and Construction, is presented with respect to steady state and transient responses.

Design of RC dual system building using special seismic detail (내진특수상세를 적용한 RC 이중골조 건물의 설계)

  • Lee, Han-Seon;Ko, Dong-Woo;Sun, Sung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.190-193
    • /
    • 2006
  • The definition of the Dual system is that the total seismic force resistance is to be provided by the combination of the moment frame and the shear walls or braced frames in proportion to their stiffness and the moment frame shall be capable of resisting at least 25% of the design force in Korean Building Code 2005 (KBC 2005). But, the definition of moment frame is ambiguous whether the moment frame include the imaginary columns in the shear wall (Case I) or include only the columns outside the shear wall (Case II). 60-story RC building was designed as dual system for Case I and Case II, and the required strength and reinforcement are compared. Moment and axial capacity of the shear wall of Case II decreased about 5% due to the absence of the column in the shear wall. The requirement of upper and bottom reinforcement of slab in Case II increased 13% and 40%, respectively, when compared to those of Case I. The required longitudinal reinforcement in columns for Case II is about 1.5 times larger than that of Case I.

  • PDF

Bond Strength of Light-weight Inorganic Ceramic Board for Fire Resistant Curtain-wall System (커튼월 층간 화재확산방지구조 적용을 위한 경량무기발포 세라믹보드의 부착강도)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.214-215
    • /
    • 2014
  • Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. This study is explain fire resistance performance of the curtain walls. And focused on bond strength of light-weight inorganic ceramic board in high temperature for fire resistant curtain-wall system. From the result, curtain-wall system high fire resistant using the light-weight inorganic ceramic board.

  • PDF

An experimental study on the impingement spray of a common-rail diesel injector (2) -atomization characteristics- (커먼레일식 디젤 인젝터의 충돌 분무에 대한 실험적 연구(2) -미립화 특성-)

  • Lee, C.S.;Park, S.W.;Seo, S.H.
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.19-26
    • /
    • 2003
  • In this study, experimental study on atomization characteristics of the fuel spray impinging on the wall was at different wall distances and angles of wall inclination. The fuel injection system was composed based on the common rail system. and the injection signal was synchronized by the delay generator. The atomization characteristics of the injected spray were analyzed in terms of the SMD and velocities which were measured by using the phase Doppler particle analyzer system. It is revealed that the free spray is atomized actively above 50mm form the injector tip. In the cases of the impinged spray, the 5MD and velocity of the impinged spray are smaller than those of the free spray. The impinged spray has the maximum near the 35mm of the radial distance from the injector axis, and the atomization performance is enhanced with the decrease of the wall distance.

  • PDF

The trial Test for the Estimation System of Deterioration of Exterior Wall by Infrared Theromography (적외선탐사기를 사용한 외벽열화평가 시스템의 구축)

  • Kwon, Young-Jin;Nishigawa, Tadashi;Oh, Sang-Keun;Park, Deuk-Kon;Choi, Long
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.398-401
    • /
    • 1996
  • It is the aim of this study to introduce the application method for the new estimation system of deterioration caused performance decrement of exterior wall by infrared theromography. With this help of this trial test, the defect such as void and honeycomb of esveria wall can be shown easily. Espicially by selecting the weathering condition, it becomes easier to identify defect than with original image. It was confirmed that this trial monitoring system is very useful to identify the defect of exterior wall.

  • PDF

Measurements of Earth Retaining Wall using Coordinate Sensor System (좌표측정 센서시스템을 이용한 흙막이 변위 계측)

  • Noh, Tae-Sung;Rhim, Hong-Chul;Han, Byung-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.196-197
    • /
    • 2015
  • Measurements of temporary earth retaining wall during construction are essential for the safety and control of building under construction. As there is a rapid development in sensor technologies, new system of coordinate sensor is developed and applied to a construction site. The new system is capable of measuring three dimensional coordinates continuously over time. It makes possible to monitor the behavior of the temporary earth retaining wall real-time. In this paper, the results of such measurements are provided with real data.

  • PDF

Unit Module Construction Method for Freeform Facade (비정형 파사드의 유닛 모듈 시공 공법 개발)

  • Kim, Sung-Jin;Park, Sung-Jin;Park, Young-Mi;Ryu, Han-Guk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.220-221
    • /
    • 2013
  • Exterior walls are designed and constructed through design focused exterior wall system. Nowadays, freeform facade design has been changing according to material, form and function of the exterior wall system. Especially, curtain wall facade system is designed and manufactured using solar shading faces. However, the traditional method have a lot of difficulties in the currently performing technology for curtain wall facade. It is important to make the freeform facade components that integrated as a surface of freeform buildings. Therefore it is necessary to develop unit module construction method for freeform facade.

  • PDF

A Study on the Improvement of Evaluation Method of Diagnosis-System for Exterior-Wall Deterioration by Infrared Thermography (적외선 탐사기를 이용한 외벽열화 진단시스템의 평가기법 향상에 관한 연구)

  • Kim, Moo-Han;Kwon, Young-Jin;Kang, Suk-Puo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.185-190
    • /
    • 1999
  • It is difficult to estimate for deterioration of exterior wall by infrared thermography, because of amount of infrared-ray radiation effected by environmental factors such as temperature properties of materials, the outside air and the amount of solar radiation. Therefore we measured the distribution of temperature by times in the same reinforced-concrete structure in order to reduce problems, occasioned by environmental factors, then we analyzed physical influence factors of the infrared thermography. It is the aim of this study to suggest basic data with regard to method of estimation-system for deterioration of exterior wall in reinforced-concrete structures.

  • PDF