• 제목/요약/키워드: Wall reflection

검색결과 170건 처리시간 0.031초

Radiation-Laminar Free Convection in a Square Duct with Specular Reflection by Absorbing-Emitting Medium

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1346-1354
    • /
    • 2002
  • The purpose of this work is to study the effects of specularly reflecting wall under the combined radiative and laminar free convective heat transfer in an infinite square duct. An absorbing and emitting gray medium is enclosed by the opaque and diffusely emitting walls. The walls may reflect diffusely or specularly. Boussinesq approximation is used for the buoyancy term. The radiative heat transfer is evaluated using the direct discrete ordinates method. The parameters under considerations are Rayleigh number, conduction to radiation parameter, optical thickness, wall emissivity and reflection mode. The differences caused by the reflection mode on the stream line, and temperature distribution and wall heat fluxes are studied. Some differences are observed for the categories mentioned above if the order of the conduction to radiation parameter is less than order of 10$\^$-3/ fer the range of Rayleigh number studied. The differences at the side wall heat flux distributions are observed as long as the medium is optically thin. As the top wall emissivity decreases, the differences between these two modes are increased. As the optical thickness decreases at the fixed wall emissivity, the differences also increase. The difference of the streamlines or the temperature contours is not as distinct as the side wall heat flux distributions. The specular reflection may alter the fluid motion.

유수실을 사석으로 채운 유공 케이슨에 대한 반사계수 실험 (Hydraulic Experiments on Reflection Coefficients for Perforated Wall Caisson with Rock Fill)

  • 김영택;이종인
    • 한국해안·해양공학회논문집
    • /
    • 제31권6호
    • /
    • pp.403-408
    • /
    • 2019
  • 일반적으로 유공벽을 갖는 케이슨(유공케이슨)은 직립식 구조물 벽면에 유공부를 설치하여 반사파의 저감, 월파량의 저감 등의 목적으로 사용된다. 본 연구에서는 유공케이슨 유수실을 골재(사석)로 채운 형태의 구조물에 대한 수리특성(반사계수)을 수리모형실험을 통해 검토하였다. 유수실을 사석으로 채운 경우가 유수실이 비어있는 일반적인 형상보다는 반사계수가 크게 나타났으나, 속채움재를 유수실에 설치하여 중량을 확보함으로서 구조물의 안정성을 확보하고, 일정 수준에서 수리특성을 만족할 수 있는 것으로 검토되었다.

불규칙파의 유공 케이슨 방파제로부터의 반사율 산정시 규칙파 모델 적용 (Application of a Regular Wave Model to Calculation of Irregular Wave Reflection from Perforated-Wall Caisson Breakwaters)

  • 서경덕;손상영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.205-208
    • /
    • 2002
  • Numerous studies have been performed to develop an analytical model that can predict the reflection of regular or irregular waves from a perforated-wall caisson breakwater. Though such irregular wave models as Suh et at. (2001) become available, regular wave models are still in extensive use because of their simplicity. In the present study, using the regular wave model of Fuggazza and Natale(1992), the reflection of irregular waves from a perforated-wall caisson breakwater was calculated in several different methods. First, the regular wave model was re-validated by the hydraulic model tests. Though the model somewhat over-predicted the reflection coefficients at larger values and under-predicted them at smaller values, overall agreement was pretty good between calculation and measurement. Then, the regular wave model was applied to calculate the irregular wave reflection in the experiments of Suh et at.(2001) and Bennett et al. (1992). In applying the regular wave model to irregular wave reflection, several different methods were used. The results showed that it is the most reasonable to use the regular wave model repeatedly for each frequency component of the irregular wave specuum with the root-mean-squared wave height for all the frequencies .

  • PDF

Investigation of Layered Structure of Fiber Cell Wall in Korean Red Pine by Confocal Reflection Microscopy

  • Kwon, Ohkyung
    • Applied Microscopy
    • /
    • 제44권2호
    • /
    • pp.61-67
    • /
    • 2014
  • Layered structures of fiber cell wall of Korean red pine (Pinus densiflora) were investigated by confocal reflection microscopy (CRM). CRM micrographs revealed detailed structures of the fiber cell wall such as S1, S2, and S3 layers as well as transition layers (S12 and S23 layers), which are present between the S1, S2, and S3 layers. Microfibril angle (MFA) measurement was possible for the S2 and S3 layer in the cell wall. The experimental results suggest that CRM is a versatile microscopic method for investigation of layered structures and MFA measurement in individual sub layer of the tracheid cell wall.

정사각형 계의 전도-복사열전달에서 정반사면의 영향 (Effects of a Specularly Reflecting Wall in an Infinite Square Duct on Conductive-Radiative Heat Transfer)

  • 변기홍;한동천
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1451-1458
    • /
    • 2001
  • The effects of a specularly reflecting surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The walls are opaque, and black or gray. The walls emit diffusely but reflect diffusely or speculary. Heat is transferred by the combined effect of conduction and radiation. The radiative heat transfer is analyzed using direct discrete-ordinates method. The parameters under study are conduction, to radiation parameter, optical depth, wall emissivity, and reflection characteristics. The specular reflection and diffuse reflection show sizeable differences when the conduction to radiation parameter is less than around 0.01. The differences appear only either on the side wall heat flux or on the medium temperature profiles for the range of this study. The differences on the side wall heat flux are observed for optical thickness less than around 0.1 However the differences on the medium temperate profiles are found for optical thickness greater than around 1. The difference increase with increasing reflectance. The specular reflection increases the well heat flux gradient along the side wall.

유공벽에 의한 파의 반사율 산정에 있어서 경험공식의 타당성 (Validity of Empirical Formulas for Estimation of Reflection Coefficient of Waves Due to Perforated Wall)

  • 윤성범;이종인;한상철
    • 대한토목학회논문집
    • /
    • 제26권6B호
    • /
    • pp.633-639
    • /
    • 2006
  • 여러 가지 두께의 유공벽을 이용하여 다양한 파 조건에 대한 반사율 실험을 실시하고 기존 이론식의 타당성을 검토하였다. 그 결과 유공벽의 두께가 두꺼우면 에너지손실계수가 기존 이론식에 사용된 예연오리피스 공식의 약 62% 정도로 감소하며, 관성저항길이는 벽의 두께가 증가함에 따라 선형적으로 증가하는 것으로 나타났다. 관성저항의 길이가 증가할수록 최소반사율을 주는 유수실 폭이 감소한다. 그러므로 본 연구에서 얻어진 결과는 유공벽 설계시 유용하게 사용될 수 있을 것으로 판단된다.

바로셀로나 파빌리온의 구축적 공간 특성에 관한 연구 (A Study on the Spatial Characteristics in the Tectonic of the Barcelona Pavilion)

  • 양재혁
    • 한국실내디자인학회논문집
    • /
    • 제33호
    • /
    • pp.19-26
    • /
    • 2002
  • This study analyzed the characteristics of spatial expression in the Barcelona Pavilion to be based on tectonics. Mies pointed out the image of materiality about the material rather than the process of tectonics using the material, and he also expressed demateriality in the image of each material through the reflection. To be liberated from structural matters, the wall has been introduced. He intended to show the design plan as the independent structural system, however, the wall actually seems to be supporting the roof that shows rather clearly self-contradictory because of the expression of materiality in the material. In terms of architectural elements; wall, roof, column, floor, and so forth, tectonic expression and abstract aesthetics stands face to face, because of hiding the productional process and transforming to line and surface in the image of materiality. The interior of the glass wall seems fairly closed space from the exterior, because materiality and reflection of materials of columns and podium. The character of experiential space is inconsistent and fragmentary because of the splendid images from maternality and reflection on the wall, and collision with the reality and the image the wall reflects, even though the geometrical space of the Pavilion's plan has the mutual penetrability and organic character.

Wave Reflection from Partially Perforated Wall Caisson Breakwater

  • K. D. Suh;Park, W. S.;Lee, D. S.
    • 한국해안해양공학회:학술대회논문집
    • /
    • 한국해안해양공학회 1996년도 정기학술강연회 발표논문 초록집
    • /
    • pp.176-183
    • /
    • 1996
  • In order to reduce wave reflection from a breakwater, a perforated wall caisson is often used. A conventional perforated wall caisson breakwater for which the water depth inside the wave chamber is the same as that on the rubble mound berm has less weight than a vertical solid caisson with the same width and moreover the weight is concentrated on the rear side of the caisson. (omitted)

  • PDF

유공방파제의 반사특성에 관한 수리실험 (Hydraulic Experiments for the Reflection Characteristics of Perforated Breakwaters)

  • 박우선;전인식;이달수
    • 한국해안해양공학회지
    • /
    • 제5권3호
    • /
    • pp.198-203
    • /
    • 1993
  • 유공방파제의 반사특성을 규명하기 위하여 파고 및 주기가 다른 여러 규칙파를 대상으로 유수실의 폭과 유공벽의 형태를 변화시키며 수리실험을 수행하였다. 실험결과, 유공방파제의 반사특성은 유수실 폭과 유수실내 파장의 비(B/L$_{c}$)에 민감하게 반응하며, B/L$_{c}$가 0.2인 부근에서 최소의 반사율을 보임을 알 수 있었다. 이러한 현상은 주로 유수실내에서의 공진현상에 기인한 것으로 판단된다. 유공벽형태(종슬리트, 횡슬리트 또는 원형 구멍)의 변화는 반사율면에 있어서 약간의 변화를 초래할 수는 있어도, 전반적인 반사특성 변화에는 영향을 주지 못함을 확인하였다.하였다.

  • PDF

연직 슬릿 유공벽의 투수계수 계산 방법의 비교 (Comparison of Methods to Calculate Permeability Parameter of Perforated Wall with Vertical Slits)

  • 서경덕;지창환;김열우
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.506-509
    • /
    • 2008
  • Mathematical models have been developed to calculate hydrodynamic characteristics of perforated-wall structures. Most of the models separate the fluid regions into front and back of the wall, assume the solution in each region, and calculate the solution by using the matching condition at the wall. The matching condition involves the permeability parameter, which can be calculated by the methods proposed by Mei et al. or Sollitt and Cross. In this study, we compare these two methods. The former is advantageous because all the related variables are known, but it gives wrong result in the limit of long waves, i.e. zero transmission and perfect reflection of very long waves. In deep water, the latter predicts smaller transmission and larger reflection than the former, and vice versa in shallow water. In the latter method, the friction coefficient decreases as the wall thickness or the porosity of the wall increases.

  • PDF