• Title/Summary/Keyword: Wall flow

Search Result 2,971, Processing Time 0.034 seconds

Fabrication of YB $a_2$C $u_3$ $O_{7-x}$ film on a (100) SrTi $O_3$ single crystal substrate by single liquid source MOCVD method ((100) SrTi $O_3$ 단결정 기판위에 단일 액상 원료 MOCVD 법에 의한 YB $a_2$C $u_3$ $O_{7-x}$ 박막 제조)

  • Jun Byung-Hyuk;Choi Jun-Kyu;Kim Ho-Jin;Kim Chan-Joong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.16-20
    • /
    • 2004
  • YB $a_2$C $u_3$$O_{7-x}$ (YBCO) films were deposited on (100) SrTi $O_3$ single crystal substrates by a metal organic chemical vapor deposition (MOCVD) system of hot-wall type using single liquid source. Under the condition of the mole ratio of Y(tmhd)$_3$:Ba(tmhd)$_2$:Cu(tmhd)$_2$= 1:2.1:2.9. the deposition pressure of 10 Torr. the MO source line speed of 15 cm/min. the Ar/ $O_2$ flow rate of 800/800 sccm. YBCO films were prepared at the deposition temperatures of 780∼89$0^{\circ}C$. In case of the YBCO films with 2.2 ${\mu}{\textrm}{m}$ thickness deposited for 6 minutes at 86$0^{\circ}C$. XRD pattern showed complete c-axis growth and SEM morphology showed dense and crack-free surface. The atomic ratios of Ba/Y and Cu/Ba in the film were 1.92 and 1.56. respectively. The deposition rate of the film was as high as 0.37 ${\mu}{\textrm}{m}$/min. The critical temperature ( $T_{c.zero}$) of the film was 87K. The critical current of the film was 104 A/cm-width. and the critical current density was 0.47 MA/$\textrm{cm}^2$. For the thinner film of 1.3 ${\mu}{\textrm}{m}$ thickness. the critical current density of 0.62 MA/$\textrm{cm}^2$ was obtained.d.

Numerical Investigation of Deformation of Thin-walled Tube Under Detonation of Combustible Gas Mixture (가연성 연소 가스의 데토네이션에 의한 얇은 관 변형 모델링)

  • Gwak, Mincheol;Lee, Younghun;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • We present the results of a multi-material numerical investigation of the propagation of a combustible gas mixture detonation in narrow metal tubes. We use an experimentally tuned one step Arrhenius chemical reaction and ideal gas equation of state (EOS) to describe stoichiometric $H_2-O_2$ and $C_2H_4-O_2$ detonations. The purely plastic deformations of copper and steel tubes are modeled using the Mie-Gruneisen EOS and Johnson-Cook strength model. To precisely track the interface motion between the detonating gas and the deforming wall, we use the hybrid particle level-sets within the ghost fluid framework. The calculated results are validated against the experimental data because the results explain the process of the generation and subsequent interaction of the expansion wave with the high-strain-rate deformation of the walls.

Numerical Study on Heat Transfer Performance of Crossflow Fin-tube Heat Exchanger Depending on Different Fan Positions (직교류 핀-튜브형 열교환기에서 팬 위치변화에 따른 열전달 성능변화 연구)

  • Kim, Won Hyung;Park, Tae Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • The convective heat transfer of a crossflow fin-tube heat exchanger was studied numerically. In order to investigate the dependence of the heat transfer performance on the fan position, several cases with different blowing and suction types were selected for the fan position. A staggered tube arrangement was used for the heat exchanger, and the temperatures of the tube wall and air were $50^{\circ}C$ and $30^{\circ}C$, respectively. The three-dimensional flow structures were examined based on the results. In addition, the convective heat transfer coefficient and mean temperature difference between the inlet and outlet of the heat exchanger were analyzed for the various fan positions, and the heat transfer performance was investigated

Effects of Drag Models on the Hydrodynamics and Heat Transfer in a Conical Fluidized Bed Combustor (원추형 유동층 연소기의 수력학적 특성 및 열전달에 항력 모델이 미치는 영향에 대한 연구)

  • Kang, Seung Mo;Abdelmotalib, Hamada;Ko, Dong Guk;Park, Woe-Chul;Im, Ik-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.11
    • /
    • pp.861-869
    • /
    • 2015
  • In this study, wall to bed heat transfer and hydrodynamic characteristics in a conical fluidized bed combustor was investigated using computational fluid dynamics method. A two-fluid Eulerian-Eulerian model was used with applying the kinetic theory for granular flow(KTGF). The effects of the two drag models, Gidaspow and the Syamlal-O'Brien model, different inlet velocities($1.4U_{mf}{\sim}4U_{mf}$) and different particle sizes on the hydrodynamics and heat transfer were studied. The results showed that the hydrodynamic characteristics such as bed expansion ratio and pressure drop were not affected significantly by the drag models. But the heat transfer coefficient was different for the two drag models, especially at lower gas inlet velocities and small particle sizes.

Natural Convection in Tilted Square Enclosure with Inner Circular Cylinder at Different Vertical Locations (내부 원형 실린더의 위치 변화에 따른 기울어진 사각 밀폐계 내부의 자연대류 현상)

  • Jeong, Seung Jae;Yoon, Hyun Sik;Choi, Changyoung;Ha, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1113-1120
    • /
    • 2013
  • A numerical analysis of the effect of the position of a circular cylinder in a $45^{\circ}$ tilted enclosure on natural convection in the enclosure is presented. The location of the cylinder is changed between -0.4 and 0.4. The Rayleigh number is varied between $10^3$ and $10^5$. The effect of the location of the cylinder on natural convection in the enclosure is analyzed by the isothermal line, stream line, and surface-averaged Nusselt number. The flow and heat transfer characteristics are independent of time in the range of the Rayleigh number and cylinder location that is considered in this study. The surface-averaged Nusselt number of the cylinder and enclosure increases as the cylinder gets closer to the wall of the enclosure.

Prediction of the Transmission Loss of Rectangular Lined Plenum Chamber by the Rayleigh-Ritz Method (Rayleigh-Ritz 방법에 의한 흡음재가 부착된 직방형 소음기의 전달 손실 예측)

  • Kim, Hoi-Jeon;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.869-872
    • /
    • 2005
  • The purpose of this study is on the prediction of the acoustic performance of the lined rectangular plenum chamber which can be used in the HVAC systems. The lined plenum chamber is modeled as a piston driven rectangular tube without mean flow and the acoustic pressure in the lined chamber is obtained by superposing the three dimensional pressure due to each of uniformly and harmonically fluctuating pistons. The arbitrary locations of inlet/outlet ports as well as the acoustic higher order modes generated at the area discontinuities of the port chamber interfaces are taken into consideration. The four-pole parameters can be derived by imposing the proper boundary conditions on each inlet and outlet ports. The lining material on the internal wall is assumed to be a bulk-reacting model. A single weak variation statement which satisfies the fluctuating rigid piston condition and the pressure and displacement continuity condition at the interface between the lining material and the airway was developed. The set of cosine functions were used as the admissible function when applying the Rayleigh-Ritz method. Computed results are compared with those predicted by using the locally-reacting lining material and experimental results, respectively. There are a good agreement shown between the results by the Rayleigh-Ritz method and the experiment results. The derived transfer matrices can be easily combined with other four-pole parameters of different types of mufflers for the calculation of the whole system performance.

  • PDF

The Types of Linkage of Carbohydrates in Wood Cell Wall (I) - The Isolation of Carbohydrates - (목재(木材) 세포벽중(細胞壁中)의 탄수화합물(炭水化合物) 간(間)의 결합(結合) 양식(樣式)(I) -탄수화합물(炭水化合物)의 단리(單離)-)

  • Lee, Sang-Pill;Lee, Jong-Yoon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.34-43
    • /
    • 1987
  • This study was performed to find out the types of linkage of carbohydrates in wood cell walls. To study the structure of linkage of carbohydrates in wood cell walls, we have attempted to find out the method holocellulose preparation and optimum condition of enzyme hydrolysis in holocellulose, and fractionate oligosaccharide with products that hydrolized partly by acetolysis and deacetylation in holocellulose. We have achieved four results. These results as follow; 1. At first. we reacted in wood meal $NaClO_2$ 1g per lignin lg for one hour and then the same of quantity $NaClO_2$ for four hours. Through these experiments, we have developed new holocellulose preparation method which had low loss of carbohydrates and high effect of the delignification. 2. The optimum condition of enzyme hydrolysis of holocellulose which had lignin was 0.005M sodium acetate buffer (pH 5.0). We have achieved 7.2% reducing sugar through the procedure that reactioned 0.01g holocellulose putting enzyme 0.03g for 72 hours. It may be supposed that 5.5% of lignin contained in holocellulose prevented enzyme contaction from holocellulose and so this lignin has resulted in the low efficiency of enzyme hydrolysis. 3. We did not fractionated from oligosaccharides which were preparated by the method of acetolysis and deacetylation in holocellulose. The reason is that holocellulose having a lot of lignin prevented prefectly partial hydrolysis from the method of acetolysis and deacetylation. 4. We attempted analysis of six standard substances through HPLC apparatus having sugar pak 1 column which we have changed flow rate and the column temperature variably. These six standard substances were D-glucose, D-mannose, D-xylose, D-galactose and L-rhamnose, L-arabinose, But sugar pak 1 column was not fitted analysis of four substances because D-galactose, D-mannose, D-xylose, L-rhamnose were agreement with elution time. And so, we could not analize four standard substances with sugar pak 1 column.

  • PDF

Dynamic Lung Compliance in Normal Subjects Measured by Pneumatograph (Pneumotachograph 로 측정한 건강인의 동적 폐 Compliance)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.195-204
    • /
    • 1977
  • Dynamic lung compliance was measured in healthy ten young[mean age, 26 years] male and five young[mean age, 25 years] female. Lung volume was integrated of the rate of flow signal which was obtained by using pneumotachograph and differential pressure transducer[PM 5, Statham]. Intrapleural pressure was measured as that of intraesophagel pressure. Esophageal ballon, 15. 5cm in length, 4ml of luminal capacity and made of thin latex, was connected to the polyethylene tube that had 12-14 side holes and was of 1.5mm of ID. Transpulmonary pressure was traced by means of differential pressure transducer[PM 131, Statham] to which connected the esophageal balloon catheter and connection tube from mouth piece. Lung volume and transpulmonary pressure were photographed by cathode ray oscilloscope camera while the subjects were breathing spontaneously. Dynamic lung compliance loop was displayed on single trace monitor and subtraction was performed for the quasi-static hysteresis. Dynamic lung compliance was measured, 1. by plotting the pressure-volume relationship 2. from the subtracted pressure-volume loop. Results were as follows. 1. Dynamic lung compliances measured by plotting of healthy young male and female were $0.202{\pm}0.06$ and $0.190{\pm}0.023L/cm$ $H_2O$ respectively. 2. When measured from subtraction loop, dynamic lung compliance for male and female were $0.327{\pm}0.107$, and $0.27{\pm}0.06L/cm$ $H_2O$ respectively. 3. Dynamic chest wall and total respiratory system compliance were also measured. 4. Dynamic lung compliance by plotting appeared to be essentially same when compared to that of static compliance reported previously from our laboratory, however, that obtained from subtraction loop revealed higher values than the compliances obtained by plotting and that of static compliance.

  • PDF

The first Korean case of poland-Mobius syndrome associated with dextrocardia (Poland-Mobius syndrome 신생아 1례)

  • Jung, Jiyoung;Kim, Han Gyu;Ahn, Hae-Mi;Cho, Su Jin;Park, Eun Ae
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.12
    • /
    • pp.1388-1391
    • /
    • 2009
  • Poland syndrome is characterized by unilateral absence or hypoplasia of the pectoralis muscle and variable degree of ipsilateral hand anomalies. Mobius syndrome is a congenital neurological disorder characterized by complete or partial facial paralysis. Although the pathogeneses of these diseases are not well-characterized, diminished blood flow to the affected side is thought to play a role. A male infant weighing 2.670 g was born at 38+3 weeks of gestation with left facial paralysis, left chest wall defect with dextrocardia, and symbrachydactyly between the second and third fingers. The combination of Poland-Mobius syndrome is rare, and only 2 cases associated with dextrocardia have been reported worldwide. Here, we report the first case of Poland-Mobius syndrome associated with dextrocardia in Korea.

Combustion Characteristics of Fuel-rich Gas Generator with Impinging Injector for a Liquid Rocket Engine (액체로켓엔진에서 충돌형 분사기 형태의 연료과잉 가스발생기 연소특성)

  • Han, Yeoung-Min;Kim, Seung-Han;Lee, Kwang-Jin;Moon, Il-Yoon;Seol, Woo-Seok;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.64-70
    • /
    • 2005
  • The overall results of hot firing tests of fuel-rich gas generator with impinging injector at design and off-design points are described. The gas generator consists of an injector head with impinging injector, a water cooled combustor wall, a turbulence ring to enhance mixing, an instrument ring measuring temperature and pressure and a nozzle. The combustion tests were successfully performed without damage of gas generator. Test results show that the outlet temperature is not dependent on residence time of hot gas within 4~6msec but dependent on chamber pressure. The relation between outlet temperature and combustion efficiency resulting from measured pressure, mass flow rate and area of nozzle throat is shown. The overall O/F ratio is the critical parameter to determine the outlet temperature and the linear correlation between two parameters is established.